The Aeroflex 3920 is a high-performance radio test set designed for professional engineering, production, and field service applications. This comprehensive platform supports analog PMR (AM, FM, SSB) measurements and advanced digital testing for modern PMR standards including P25, TETRA, DMR, dPMR, NXDN, and HPD. It features high-accuracy RF and audio baseband generators, a 5 MHz channel spectrum analyzer, and a 4 MHz dual-channel oscilloscope.

Specifications

General

ParameterValue
InterfacesGPIB (IEEE-488.2), LAN (Ethernet), USB Host, USB Device, RS-232, VGA Monitor Output
Display6.4-inch Color TFT LCD, VGA resolution (640 x 480)

Physical

ParameterValue
Power Supply100 to 240 VAC, 50 to 60 Hz / 400 Hz, 150 W maximum
Operating Temperature0 to +50 °C
Dimensions (W×H×D)356 mm × 197 mm × 520 mm
Weight16.5 kg

RF Signal Generator

ParameterValue
RF Generator Frequency Range10 MHz to 2.7 GHz
RF Generator Frequency Resolution1 Hz
RF Generator Frequency AccuracySame as internal reference
RF Generator Output Level Range (T/R Port)-130 dBm to -40 dBm
RF Generator Output Level Range (Duplex Port)-130 dBm to -10 dBm
RF Generator Output Level Resolution0.1 dB
RF Generator Output Level Accuracy±1.5 dB (typically < ±1.0 dB)
RF Generator Harmonics<-30 dBc
RF Generator Non-Harmonics<-50 dBc (for offsets > 10 kHz)
RF Generator Phase Noise<-95 dBc/Hz (at 20 kHz offset, 1 GHz carrier)
FM Deviation Range0 to 150 kHz
FM Deviation Resolution1 Hz
FM Deviation Accuracy±3% (plus residual FM)
AM Modulation Depth Range0% to 90%
AM Modulation Resolution0.1%
AM Modulation Accuracy±5% of setting (plus residual AM)

RF Receiver

ParameterValue
RF Receiver Frequency Range10 MHz to 2.7 GHz
RF Receiver Input Impedance50 Ω nominal
RF Receiver Input VSWR (T/R Port)<1.25:1 (up to 1 GHz)
RF Receiver Input VSWR (Antenna Port)<1.5:1
Maximum Input Power (T/R Port, Continuous)50 W
Maximum Input Power (T/R Port, Short-term)125 W (with duty cycle, 30 seconds max)
RF Power Measurement Range (T/R Port)100 mW to 125 W
RF Power Measurement Accuracy±10% (±0.4 dB)
RF Power Measurement Resolution0.01 dB or 3 digits
FM Deviation Measurement Range0 to 150 kHz
FM Deviation Measurement Accuracy±3% (plus residual)
AM Depth Measurement Range0% to 90%
AM Depth Measurement Accuracy±5% (plus residual)
Demodulation TypesAM, FM, SSB (USB, LSB)

Audio Generator & Analyzer

ParameterValue
Audio Generator Count3 independent audio modulators/generators
Audio Generator Frequency Range1 Hz to 20 kHz
Audio Generator Frequency Resolution0.1 Hz
Audio Generator Output Level Range0.1 mV to 5 V RMS (into 600 Ω)
Audio Generator Output Distortion (THD)<0.5% (at 1 kHz, 1 V RMS)
Audio Analyzer Frequency Range10 Hz to 20 kHz
Audio Analyzer Level Range10 mV to 30 V RMS
Distortion Measurement Range (THD)0% to 100%
Distortion Measurement Accuracy±0.5% distortion (±10% of reading)
SINAD Measurement Range0 to 40 dB
SINAD Resolution0.1 dB
Audio Filters300 Hz LP, 300 Hz HP, 3 kHz LP, 15 kHz LP, C-message, CCITT psophometric
DTMF Generator/DecoderSupported
DCS Generator/DecoderSupported

Digital Radio Test Capabilities

ParameterValue
Supported Digital Radio TechnologiesP25, TETRA, DMR, dPMR, NXDN, HPD (option dependent)
TETRA Test OptionSupported (including MS and BS test modes)
APCO P25 Test OptionSupported (Phase 1 Conventional/Trunked and Phase 2)
DMR Test OptionSupported (TIER II & TIER III)
NXDN / dPMR Test OptionSupported

Spectrum Analyzer & Oscilloscope

ParameterValue
Spectrum Analyzer Frequency Range10 MHz to 2.7 GHz
Spectrum Analyzer Resolution Bandwidth (RBW)100 Hz to 1 MHz (in 1-3-10 sequence)
Spectrum Analyzer Video Bandwidth (VBW)10 Hz to 1 MHz
Oscilloscope Channels1
Oscilloscope BandwidthDC to 50 kHz

Reference Frequency

ParameterValue
Internal Reference Frequency10 MHz
Standard Reference Temperature Stability±0.1 ppm
Standard Reference Aging Rate±0.1 ppm per year
External Reference Input Frequency10 MHz (nominal)

Environmental & General

ParameterValue
Storage Temperature Range-40 °C to +71 °C
Remote Control LanguageSCPI compliant command set

Power Requirements

ParameterValue
AC Input Voltage100 to 240 VAC
AC Input Frequency50 to 60 Hz
Power Consumption150 W (typical)

Environmental

ParameterValue
Environmental ComplianceMIL-PRF-28800F Class 3
Operating HumidityUp to 95% RH (non-condensing)
Operating AltitudeUp to 3,048 m (10,000 ft)
Shock & Vibration ComplianceMeets MIL-PRF-28800F Class 3

Internal Reference

ParameterValue
Warm-up Time15 minutes (standard reference)

Audio Analyzer

ParameterValue
Audio Frequency Counter Resolution0.1 Hz

Reference Timebase Options

ParameterValue
High Stability OCXO Temperature Stability±0.01 ppm (0 °C to 50 °C, Option 10)
High Stability OCXO Aging Rate±0.1 ppm/year (±0.005 ppm/day after 30 days of continuous operation, Option 10)

RF Generator - Phase Modulation

ParameterValue
Phase Modulation (PM) Generator Deviation Range0 to 10 rad
Phase Modulation (PM) Generator Deviation Resolution0.001 rad
Phase Modulation (PM) Generator Deviation Accuracy±5% (at 1 kHz)

RF Receiver - Phase Modulation Analyzer

ParameterValue
Phase Modulation (PM) Analyzer Deviation Range0 to 10 rad
Phase Modulation (PM) Analyzer Deviation Accuracy±5% of reading ±0.05 rad (at 1 kHz)

Audio Generator

ParameterValue
Audio Generator Output Impedance<2 Ω

Oscilloscope

ParameterValue
Oscilloscope Vertical Sensitivity Range10 mV/div to 10 V/div (in 1-2-5 sequence)
Oscilloscope Timebase Range50 µs/div to 100 ms/div (in 1-2-5 sequence)
Oscilloscope Maximum Input Voltage30 V RMS

RF Generator

ParameterValue
RF Generator Output VSWR (Duplex Port)<1.25:1 (<1 GHz), <1.30:1 (<2.7 GHz)

Technology

RF and PMR (Private Mobile Radio) Testing

Applications

Parametric testing of analog and digital radio systems (TETRA, P25, DMR, dPMR, NXDN)