The Agilent 1200 Series HPLC is a highly configurable, modular high-performance liquid chromatography system widely adopted in analytical chemistry, pharmaceutical QA/QC, and research. Expanding upon the industry-standard 1100 Series, the 1200 Series provides flexible deployment options, offering up to 400 bar maximum pressure in its standard modules and up to 600 bar for Rapid Resolution Liquid Chromatography (RRLC) configurations.

Specifications

General

ParameterValue
InterfacesCAN, LAN, GPIB, RS-232, APG Remote (configuration dependent)
DisplayNone (controlled via software or optional G1323B Control Module)

Physical

ParameterValue
Power Supply100 - 240 VAC, 50/60 Hz (per module)
Operating Temperature4 to 55 °C

General System Specifications

ParameterValue
System ConfigurationModular (Pump, Autosampler, Column Compartment, Detector modules)
Maximum Operating Pressure400 bar / 5880 psi (Standard 1200 Series) / 600 bar / 8700 psi (1200 Series RRLC)
pH Range1.0 to 12.5 (standard materials)

Solvent Delivery System (Pump)

ParameterValue
Flow Rate Range0.001 to 10.0 mL/min (Standard Pumps) / up to 5.0 mL/min (RRLC Binary Pump SL)
Number of Solvents / ChannelsUp to 4 (Quaternary Pump) or 2 (Binary Pump)
Flow Precision≤ 0.07 % RSD (or ≤ 0.02 min SD)
Pressure Pulsation< 2 % amplitude (typically < 1 %) at 1 mL/min isopropanol
Compressibility CompensationUser-selectable, based on mobile phase properties
Degasser TypeVacuum membrane degasser

Sample Management (Autosampler)

ParameterValue
Injection Volume Range0.1 to 100 µL (Standard Autosampler G1329A)
Injection Precision< 0.25 % RSD (from 5 to 100 µL, Standard Autosampler)
Sample Capacity (Vials)100 x 2 mL vials (Standard tray)
CarryoverTypically < 0.1 % (without automated needle wash)

Column Compartment

ParameterValue
Temperature Control Range10 °C below ambient to 80 °C (G1316A TCC)
Temperature Stability± 0.15 °C
Column CapacityUp to 3 columns of 30 cm length (G1316A TCC)

Detector Specifications (DAD / UV-Vis)

ParameterValue
Wavelength Range190 to 950 nm (G1315B DAD option) / 190 to 600 nm (G1314B VWD option)
Light SourceDeuterium and Tungsten lamps (DAD)
Flow Cell Volume13 µL (Standard Flow Cell)
Flow Cell Path Length10 mm (Standard Flow Cell)
Maximum Flow Cell Pressure120 bar (Standard Flow Cell)

Software and Control

ParameterValue
Chromatography Data System (CDS)Agilent ChemStation, EZChrom, OpenLAB CDS

Connectivity and Interfaces

ParameterValue
Controller Area Network (CAN)Yes (Inter-module communication standard)

Environmental and Safety Compliance

ParameterValue
Operating Humidity Range< 95 % non-condensing
Safety CertificationsCSA, UL, CE

Physical and Power Specifications

ParameterValue
Line Voltage Range100 - 240 VAC, ± 10 %
Line Frequency50 / 60 Hz, ± 5 %

Pump & Fluidics

ParameterValue
Pump MechanismDual-piston in series with proprietary servo-controlled variable stroke drive
Gradient MixingLow-pressure quaternary or high-pressure binary mixing (pump module dependent)
Composition Precision< 0.2 % RSD or < 0.04 min SD (whichever is greater, at 0.2 and 1 mL/min)

Detection

ParameterValue
Data Acquisition RateUp to 80 Hz (detector module dependent)

Software & Control

ParameterValue
Maintenance FeaturesEarly Maintenance Feedback (EMF) for continuous usage tracking (e.g., seal wear, lamp hours)

Environmental

ParameterValue
Maximum Operating Altitude2000 m
Storage Temperature-40 °C to +70 °C

Compliance

ParameterValue
Installation CategoryII (IEC 61010)

Technology

High-Performance Liquid Chromatography (HPLC)

Applications