The Anritsu MS2026A VNA Master is a handheld Vector Network Analyzer designed for field-based RF engineering and maintenance. Operating from 2 MHz to 6 GHz, it delivers vector-corrected 1-port and 1-path 2-port measurements, enabling accurate assessments of cable and antenna systems. Its rugged handheld form factor, daylight-viewable display, and battery-powered operation make it well-suited for demanding field service and installation environments.

Specifications

General

ParameterValue
InterfacesUSB 2.0 (Host and Device), 10/100 Base-T Ethernet, Compact Flash (CF) Card Slot
DisplayHigh-resolution daylight-viewable TFT color display

Physical

ParameterValue
Power SupplyExternal AC-to-DC adapter (12 to 15 VDC), or rechargeable Li-Ion Battery
Operating Temperature-10 °C to +55 °C
Dimensions (W×H×D)315 mm × 211 mm × 78 mm
Weight< 2.9 kg

Frequency & Stimulus Specifications

ParameterValue
Frequency Range2 MHz to 6 GHz
Frequency Resolution10 kHz
Frequency Accuracy± 2.5 ppm (standard at 25 °C), ± 25 ppb (with GPS lock Option 31)
Number of Test Ports2
Test Port Impedance50 Ω
Output Power0 dBm (typical, High), -35 dBm (typical, Low)

Receiver & Dynamic Range Specifications

ParameterValue
System Dynamic Range≥ 80 dB (2 MHz to 3 GHz), ≥ 70 dB (3 GHz to 6 GHz)
Maximum Input Level+20 dBm (damage level), ± 50 VDC

Measurement Speed & Settings

ParameterValue
Measurement Time per Point2 ms / data point (typical)

Measurement Capabilities & Calibration

ParameterValue
Option 5Power Monitor (requires external detector)

System, Controller & Storage

ParameterValue
Internal Data StorageUp to 1000 traces and setups
Supported Local LanguagesEnglish, Spanish, Italian, French, German, Japanese, Korean, Chinese

Hardware Interfaces & Connections

ParameterValue
Test Port Connector TypeType N, female
Option 10Built-in variable +12 V to +32 V Bias Tee
Option 31GPS Receiver (includes GPS antenna)

Physical, Environmental & Power

ParameterValue
Battery Operating Time> 3 hours (with included battery)

VNA Performance

ParameterValue
Number of Data Points2 to 4001
IF Bandwidth (IFBW)10 Hz, 20 Hz, 50 Hz, 100 Hz, 200 Hz, 500 Hz, 1 kHz, 2 kHz, 5 kHz, 10 kHz, 20 kHz, 50 kHz, 100 kHz
Measurement FormatsLog Magnitude, Phase, SWR, Group Delay, Linear Magnitude, Real, Imaginary, Smith Chart, Polar
Corrected Directivity> 42 dB (2 MHz to 6 GHz)

Environmental

ParameterValue
Storage Temperature-40 °C to +75 °C
Measurement Altitudeup to 4,600 m (operating)
Operating Humidity95% maximum, non-condensing

Options

ParameterValue
Option 2Time Domain
Option 15Vector Voltmeter
Option 19High-Accuracy Power Meter

Frequency Reference

ParameterValue
Frequency Aging±1.0 ppm/year
Frequency Temperature Stability±1.0 ppm (-10 °C to 50 °C)
External Reference Input Frequency10 MHz
External Reference Input Level-10 dBm to +10 dBm

Option 10 Built-in Bias Tee

ParameterValue
Bias Tee Voltage Range+12 V to +32 V (0.1 V steps)
Bias Tee Maximum Current450 mA
Bias Tee Maximum Power6 W

GPS Receiver (Option 31)

ParameterValue
GPS ConnectorSMA, Female

Compliance & Safety

ParameterValue
Environmental ResistanceMIL-PRF-28800F Class 2
Safety StandardsEN 61010-1
EMC StandardsEN 61326-1:2006

Power & Battery

ParameterValue
AC Adapter Input100 V AC to 240 V AC, 50 Hz to 60 Hz
AC Adapter Output15 V DC

Vector Voltmeter (Option 15)

ParameterValue
Vector Voltmeter CW Frequency Range2 MHz to 6 GHz

Time Domain (Option 2)

ParameterValue
Time Domain Sweep ModesLow Pass Step, Low Pass Impulse, Bandpass Impulse
Time Domain WindowingRectangular, Nominal, Low Sidelobe, Min Sidelobe

High-Accuracy Power Meter (Option 19)

ParameterValue
Compatible Power SensorsAnritsu USB Power Sensors (e.g., MA24106A, MA24108A, MA24118A, MA24126A)

Power Monitor (Option 5)

ParameterValue
Compatible DetectorsAnritsu 560 Series Detectors

Inputs & Outputs

ParameterValue
External Trigger InputTTL compatible

Technology

Vector Network Analysis

Applications

Antenna, Cable, and RF Component Testing