The Anritsu MT8212B Cell Master is a comprehensive, lightweight, handheld cable, antenna, and base station analyzer designed for wireless network installation, maintenance, and troubleshooting. It consolidates multiple test instruments into a single portable device, including a 4 GHz cable and antenna analyzer, a 3 GHz spectrum analyzer, a transmitter analyzer, an interference analyzer, and a T1/E1 analyzer.

Specifications

General

ParameterValue
InterfacesRS-232 serial interface (9-pin D-sub)
Display640 x 480 color TFT LCD

Physical

ParameterValue
Power Supply12 to 15 VDC, 3.0 A max via external AC-DC adapter (100 to 240 VAC, 50 to 60 Hz)
Operating Temperature-10°C to 55°C
Dimensions (W×H×D)312 x 211 x 79 mm
Weight2.28 kg

Frequency Specifications

ParameterValue
Frequency Range (Cable & Antenna)25 MHz to 4.0 GHz
Frequency Range (Spectrum Analyzer)100 kHz to 3.0 GHz
Frequency Reference Accuracy±1.0 ppm
Reference Aging Rate±1.0 ppm/year
Reference Temperature Stability±1.0 ppm (0°C to 50°C)
Resolution Bandwidth (RBW) Range100 Hz to 1 MHz (1-3 sequence)
Video Bandwidth (VBW) Range3 Hz to 1 MHz (1-3 sequence)

RF Input & Receiver

ParameterValue
Maximum Safe Input Level+30 dBm (1 W) continuous, ±50 VDC
RF Input Impedance50 Ω
RF Input Connector TypeType N, female
Displayed Average Noise Level (DANL)-135 dBm (typical at 1 GHz, 100 Hz RBW, preamp on)
RF Input VSWR< 1.5:1 (typical)

Signal Analysis & Measurements

ParameterValue
Return Loss Measurement Range0 to 60 dB
VSWR Measurement Range1.00 to 65.00
Cable Loss Measurement Range0 to 30 dB
Sweep Resolution (Data Points)130, 259, 517
Sweep Speed< 2.5 ms per data point (typical)
Directivity (Corrected)> 42 dB
Source Power (Cable & Antenna)-10 dBm (typical)

Signal Generation

ParameterValue
CW Output Frequency Range25 MHz to 3.0 GHz

T1/E1 Analyzer

ParameterValue
T1 Transmission Rate1.544 Mbps
E1 Transmission Rate2.048 Mbps
T1/E1 Connector TypeBantam jacks
T1/E1 Impedance Settings100 Ω (T1), 120 Ω / 75 Ω (E1)
T1 Line Coding Settings (Option 50)AMI, B8ZS
E1 Line Coding Settings (Option 50)AMI, HDB3
T1 Framing Formats (Option 50)D4 (SF), ESF
E1 Framing Formats (Option 50)PCM30, PCM30C, PCM31, PCM31C

Power Requirements

ParameterValue
Battery ChemistryRechargeable NiMH
Battery Operating Timeup to 2.5 hours

Physical & Environmental

ParameterValue
Storage Temperature Range-51°C to 82°C
Operating Humidity Rangeup to 95% RH (non-condensing)
Operating Altitude Limit4,600 m

Compliance & Calibration

ParameterValue
Calibration Cycle12 months

Cable & Antenna Analyzer Performance

ParameterValue
Frequency Resolution (Cable & Antenna)100 kHz
DTF RangeUp to 1250 m (4100 ft)
DTF Resolution(1.5 x 10^8 x Vp) / Delta F (meters)

Spectrum Analyzer Performance

ParameterValue
Frequency Span Range10 Hz to 2.99 GHz, 0 Hz (zero span)
Zero Span Sweep Time50 µs to 20 s
SSB Phase Noise≤ -75 dBc/Hz @ 30 kHz offset
Overall Amplitude Accuracy±1.0 dB typical (100 kHz to 3.0 GHz, for input levels ≥ -50 dBm)

GPS Receiver

ParameterValue
GPS Antenna Connector (Option 31)SMA female, 50 Ω
GPS Time to First Fix2.5 minutes cold start, 5 seconds warm start

External Reference

ParameterValue
External Reference Input Frequencies1 MHz, 5 MHz, 10 MHz, 13 MHz, 15 MHz, 19.66 MHz
External Reference Connector TypeBNC female, 50 Ω

Power Meter

ParameterValue
Internal Power Meter Frequency Range (Option 29)4.5 MHz to 3.0 GHz
Internal Power Meter Display Range (Option 29)-80 dBm to +80 dBm

RF Output (Reflection Port)

ParameterValue
RF Output Connector TypeN, female
RF Output Impedance50 Ω

Bias Tee (Option 10)

ParameterValue
Bias Tee Output Voltage Range12 V to 24 V (variable in 1 V steps) (Option 10)
Bias Tee Maximum Current250 mA (Option 10)
Bias Tee Maximum Power6 W (Option 10)

Channel Scanner (Option 27)

ParameterValue
Channel Scanner CapacityUp to 20 channels (Option 27)

High Accuracy Power Meter (Option 19)

ParameterValue
High Accuracy Power Meter Sensor CompatibilityAnritsu PSN50 / MA24105A / MA24106A (Option 19, sensor-dependent)
High Accuracy Power Meter Frequency Range50 MHz to 6 GHz (sensor-dependent) (Option 19)
High Accuracy Power Meter Dynamic Range-30 dBm to +20 dBm (sensor-dependent) (Option 19)

Internal Power Meter (Option 29)

ParameterValue
Internal Power Meter Offset Range-100 dB to +100 dB (Option 29)
Internal Power Meter Resolution0.1 dB (Option 29)

T1/E1 Analyzer (Option 50)

ParameterValue
T1 Line Build Out (LBO) Settings0 dB, -7.5 dB, -15 dB, -22.5 dB (Option 50)
T1/E1 Test PatternsPRBS (9, 11, 15, 20, 23), All Ones, All Zeros, 1:1, 1:7, 2:8, User-defined (Option 50)
T1/E1 Error Detection TypesBPV (Bipolar Violation), Frame Bit Error, CRC Error, Pattern Error (Option 50)

General & Storage

ParameterValue
Internal Trace Storage CapacityUp to 200 traces

Compliance

ParameterValue
Safety ComplianceConforms to EN 61010-1
EMC ComplianceConforms to EN 61326-1

Technology

RF / Cellular

Applications

Base Station Installation, Antenna Alignment, and Interference Analysis