The Anritsu BTS Master MT8221B is a high-performance, battery-operated handheld base station analyzer designed to install, commission, and troubleshoot 2G, 3G, and 4G wireless networks. Combining a multi-functional cable and antenna analyzer, a spectrum analyzer, and a power meter with up to 20 MHz demodulation bandwidth, the MT8221B offers cell-site technicians a rugged, all-in-one field tool.

Specifications

General

ParameterValue
InterfacesLAN (RJ45), 2x USB 2.0 Type A, 1x Mini-USB Type B, SMA Female (GPS Antenna), BNC Female (External Reference, External Trigger), 2x Type N Female (RF In, RF Out/SWR), 3.5 mm Headphone Jack
Display8.4-inch daylight-viewable color TFT touchscreen, 800 x 600 resolution

Physical

ParameterValue
Power Supply12 to 15 VDC (battery or external AC/DC adapter)
Operating Temperature-10 °C to 55 °C
Dimensions (W×H×D)315 mm x 211 mm x 77 mm (12.4 in x 8.3 in x 3.0 in)
Weight4.9 kg (10.8 lbs)

Spectrum Analyzer Performance

ParameterValue
Frequency Range150 kHz to 7.1 GHz
Displayed Average Noise Level (DANL)-163 dBm in 1 Hz RBW
SSB Phase Noise-100 dBc/Hz @ 10 kHz offset at 1 GHz
Dynamic Range> 95 dB in 1 Hz RBW
Frequency Reference Accuracy< ±25 ppb with GPS On
Resolution Bandwidth (RBW) Range10 Hz to 3 MHz
Video Bandwidth (VBW) Range1 Hz to 3 MHz
Zero-Span IF Output Bandwidth30 MHz

Cable and Antenna Analyzer Performance

ParameterValue
Port Configuration1-Port
Supported MeasurementsReturn Loss, VSWR, Cable Loss, Distance-to-Fault (DTF), 1-Port Phase

Signal Analyzer and Demodulation

ParameterValue
Demodulation Bandwidth Capability20 MHz
Supported StandardsGSM/EDGE, W-CDMA/HSPA+, LTE, TD-SCDMA/HSDPA, CDMA, EV-DO, Fixed WiMAX, Mobile WiMAX
RF Quality MeasurementsOccupied Bandwidth, Channel Power, ACPR, Carrier-to-Interference (C/I)

Interference Analyzer and Receiver Features

ParameterValue
Interference Analyzer FeaturesSpectrogram, Signal Strength, RSSI, Signal ID

System Features & Productivity

ParameterValue
Warm-up Time< 5 minutes
Included PC SoftwareMaster Software Tools (MST)
Remote Access ProtocolRemote Access Tool (RAT) over Internet

Environmental and Regulatory

ParameterValue
Storage Temperature Range-40 °C to 75 °C

Cable & Antenna Analyzer

ParameterValue
Cable and Antenna Analyzer Frequency Range10 MHz to 4.0 GHz
Cable and Antenna Analyzer Frequency Resolution1 kHz
Cable and Antenna Analyzer Sweep Speed1.0 ms/point (typical)

Spectrum Analyzer

ParameterValue
Spectrum Analyzer Tuning Resolution1 Hz
Spectrum Analyzer Attenuator Range0 dB to 65 dB in 5 dB steps
Maximum Input Damage Level+30 dBm, ±50 VDC
Third-Order Intercept (TOI)+15 dBm (typical at 2.4 GHz)

Power Meter

ParameterValue
Internal Power Meter Frequency Range10 MHz to 7.1 GHz
Internal Power Meter Display Range-100 dBm to +30 dBm

GPS (Option 31)

ParameterValue
Frequency Accuracy (GPS Locked)< ±25 ppb (Option 31)

Power & Storage

ParameterValue
Battery Operating Time2.0 hours (typical)
Internal Storage Capacity> 4000 traces/setups

Environmental & Standards

ParameterValue
Ruggedness StandardMIL-PRF-28800F Class 2

Receiver & Preamplifier

ParameterValue
Built-in PreamplifierStandard, 150 kHz to 7.1 GHz

Options & Measurements

ParameterValue
Vector Voltmeter Frequency Range10 MHz to 4.0 GHz (requires Option 15)
High Accuracy Power Meter CompatibilityCompatible with USB Power Sensors (requires Option 19)
Interference Analyzer Option (Option 25)Includes spectrogram, signal strength, RSSI, signal ID, and interference mapping
Channel Scanner Option (Option 27)Scans up to 20 channels (frequencies or user-defined channels)

Power & Bias

ParameterValue
Internal Bias Tee Voltage Output12 V to 32 V (requires Option 10)

Options & Accessories

ParameterValue
GPS Receiver Option (Option 31)Requires external GPS antenna; supports passive or active 3.3 V / 5 V antennas

Frequency Reference

ParameterValue
External Reference Input Level-10 dBm to +10 dBm

Environmental

ParameterValue
Maximum Operating Altitude4,600 m (15,000 ft)

Compliance

ParameterValue
EMC ComplianceConforms to European Union EN 61326-1 standards for Class A equipment
Safety ComplianceConforms to European Union EN 61010-1 standards

Technology

Base Station Analysis & RF Testing

Applications

Wireless Infrastructure Testing and Troubleshooting