The Anritsu S361E Site Master is a high-performance, rugged, and portable cable and antenna analyzer designed to operate over the 2 MHz to 6 GHz frequency range. Highly trusted by field technicians, wireless providers, and contractors, it simplifies installation, deployment, and maintenance of antenna systems with precise measurements, integrated calibration options, and field-proven durability.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | USB 2.0 Host (Type A) x2, USB 2.0 Client (Mini-B) x1, RJ45 LAN (10/100 Mbps) x1 |
| Display | 8.4 in Resistive TFT touchscreen, 800 × 600 resolution |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 100 V AC to 240 V AC, 50 Hz to 60 Hz (via AC/DC adapter); 12 V DC to 15 V DC input, 12 W typical |
| Operating Temperature | -10 °C to +55 °C |
| Dimensions (W×H×D) | 273 mm × 199 mm × 91 mm |
| Weight | 2.71 kg (6.0 lbs) |
Frequency
| Parameter | Value |
|---|---|
| Frequency Range | 2 MHz to 6 GHz |
| Frequency Resolution | 1 kHz |
| Frequency Accuracy | ±2.5 ppm @ 25 °C |
| Frequency Aging | ±1.0 ppm/year |
Measurements and Performance
| Parameter | Value |
|---|---|
| Supported Measurement Modes | Return Loss, VSWR, Cable Loss, Distance-to-Fault (DTF) Return Loss, Distance-to-Fault (DTF) VSWR, 1-Port Phase, Smith Chart (50/75 Ω) |
| Return Loss Range | 0 to 60 dB |
| Return Loss Resolution | 0.01 dB |
| VSWR Range | 1 to 65 |
| VSWR Resolution | 0.01 |
| Cable Loss Range | 0 to 30 dB |
| Cable Loss Resolution | 0.01 dB |
| Distance-to-Fault (DTF) Maximum Range | Up to 1500 m (4921 ft) depending on cable loss |
| One-Port Phase Range | -180° to +180° |
| Velocity Factor Range | 0.000 to 1.000 |
| On-Channel Interference Immunity | +17 dBm |
| On-Frequency Interference Immunity | +13 dBm |
RF Port Specifications
| Parameter | Value |
|---|---|
| RF Out Port Connector Type | Type N, female |
| RF Out Port Impedance | 50 Ω |
| RF Out Port Maximum Input Power (Damage Level) | +23 dBm |
| RF Out Port Maximum DC Voltage | ±50 V DC |
Sweep and Triggering
| Parameter | Value |
|---|---|
| Sweep Time per Data Point | 1.0 ms (typical) |
| Sweep Points | 137, 275, 551, 1102, 2204 |
| Sweep Triggers | Single, Continuous |
| Limit Lines | Upper/Lower, Single/Multi-segment, Limit Envelope |
Calibration and Standards
| Parameter | Value |
|---|---|
| Calibration Methods | OSL (Open-Short-Load), FlexCal, InstaCal |
| Recommended Calibration Cycle | 12 months |
Display and User Interface
| Parameter | Value |
|---|---|
| Display Type | Resistive TFT Color Touchscreen |
| Display Size | 8.4 in (213 mm) diagonal |
| Display Resolution | 800 x 600 (SVGA) |
| On-Screen Language Support | English, French, German, Spanish, Chinese, Japanese, Korean, Italian, Russian |
Connectivity and Interfaces
| Parameter | Value |
|---|---|
| USB Host Port (Type A) | 2 ports, USB 2.0 |
| USB Client Port (Type B) | 1 port, Mini-B, USB 2.0 |
| LAN / Ethernet Interface | RJ45, 10/100 Mbps |
| External Reference Input | 10 MHz (BNC, female) |
Data Storage and Software
| Parameter | Value |
|---|---|
| Internal Memory Capacity | > 2000 files (traces, setups, screen captures) |
| External Storage Support | USB Flash Drive |
| PC Analysis Software | Line Sweep Tools (LST), Master Software Tools (MST) |
| Report Generation Formats | PDF, HTML, CSV |
| Pre-programmed Cable Standards Directory | Built-in list of over 100 cable types |
Power Supply and Battery
| Parameter | Value |
|---|---|
| AC Adapter Input Voltage Range | 100 V AC to 240 V AC, 50 Hz to 60 Hz |
| AC Adapter Output Voltage | 12 V DC to 15 V DC |
| Battery Type | Lithium-Ion, rechargeable |
| Battery Operating Time | Up to 4.0 hours |
| Battery Charging Time | 4 hours (typical, unit off) |
Environmental and Mechanical
| Parameter | Value |
|---|---|
| Storage Temperature Range | -40 °C to +75 °C |
| Relative Humidity | 95% RH, non-condensing |
| Shock and Vibration Compliance | MIL-PRF-28800F Class 2 |
| Altitude Limits | 4600 m (15000 ft), operating |
Bias Tee (Option 10)
| Parameter | Value |
|---|---|
| Bias Tee Output Voltage Range | +12 V to +32 V (Option 10 dependent) |
| Bias Tee Output Voltage Resolution | 0.1 V (Option 10 dependent) |
| Bias Tee Maximum Current | 450 mA (Option 10 dependent) |
| Bias Tee Maximum Power | 8 W (Option 10 dependent) |
2-Port Transmission Measurement (Option 21)
| Parameter | Value |
|---|---|
| 2-Port Transmission Measurement Frequency Range | 2 MHz to 6 GHz (Option 21 dependent) |
| Dynamic Range (2 MHz to 4 GHz) | 80 dB (Option 21 dependent) |
| Dynamic Range (4 GHz to 6 GHz) | 70 dB (Option 21 dependent) |
GPS Receiver (Option 31)
| Parameter | Value |
|---|---|
| GPS Frequency Accuracy | < ±25 ppb (GPS on, after 3 minutes warm-up, Option 31 dependent) |
| GPS Antenna Connector | SMA, female (Option 31 dependent) |
| GPS Antenna Supply Voltage | 3.3 V or 5 V (Option 31 dependent) |
| GPS Tracking Sensitivity | -162 dBm |
| GPS Acquisition Sensitivity | -148 dBm |
| GPS Cold Start Acquisition Time | 2.5 minutes (typical) |
| GPS Warm Start Acquisition Time | 5 seconds (typical) |
CW Generator (Option 28)
| Parameter | Value |
|---|---|
| CW Generator Frequency Range | 2 MHz to 6 GHz (Option 28 dependent) |
| CW Generator Output Power | -5 dBm typical (Option 28 dependent) |
High Accuracy Power Meter (Option 19)
| Parameter | Value |
|---|---|
| Compatible USB Power Sensors | MA24105A, MA24106A, MA24108A, MA24118A, MA24126A, MA24208A, MA24218A (Option 19 dependent) |
RF Input Port
| Parameter | Value |
|---|---|
| RF In Port Connector Type | Type N, female (Option 21 dependent) |
| RF In Port Impedance | 50 Ω (Option 21 dependent) |
| RF In Port Damage Level | +23 dBm (Option 21 dependent) |
| RF In Port Maximum DC Voltage | ±50 VDC (Option 21 dependent) |
Regulatory & Compliance
| Parameter | Value |
|---|---|
| Safety Compliance Standards | EN 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-1 |
| EMC Compliance Standards | EN 61326-1, EN 55011, AS/NZS CISPR 11 |
2-Port Transmission Measurement
| Parameter | Value |
|---|---|
| Load Match | ≥ 42 dB (typical) |
Inputs & Outputs
| Parameter | Value |
|---|---|
| External Reference Input Impedance | 50 Ω |
| External Reference Input Frequency | 10 MHz |
| External Reference Input Level | -10 dBm to +10 dBm |
| External Trigger Input Level | TTL compatible |
| LAN Ethernet Speed | 10/100 Mbps |
Power Meter (Option 19)
| Parameter | Value |
|---|---|
| High Accuracy Power Meter Resolution | 0.01 dB |
Technology
Cable and Antenna Analysis
Applications
Antenna installation, field maintenance, troubleshooting, and sweep testing