The Boonton Electronics 4500A is a high-performance RF Peak Power Analyzer designed for capturing, displaying, and analyzing fast RF power pulses. Featuring standard dual RF channels, a high-resolution color display, and a built-in 1.002 GHz step calibrator, the 4500A is optimized for demanding radar, electronic warfare, and wireless communication testing applications.

Specifications

General

ParameterValue
InterfacesGPIB (IEEE-488), RS-232, Centronics Parallel, VGA out
DisplayColor TFT LCD, 640×480 resolution
Removable Storage3.5-inch 1.44 MB floppy disk drive
Internal Setup StorageUp to 10 instrument configurations in non-volatile RAM

Physical

ParameterValue
Power Supply90 to 260 V AC, 47 to 63 Hz, 120 VA max
Operating Temperature0 to 50 °C
Dimensions (W×H×D)438×178×470 mm
Weight14 kg

Input Channels & Configuration

ParameterValue
Optional Analog Channels2 (for voltage inputs)
Compatible SensorsBoonton 56000 and 57000 series peak power sensors

Measurement Ranges & Performance

ParameterValue
Frequency Range30 MHz to 40 GHz (sensor dependent)
Power Dynamic Range-40 dBm to +20 dBm (sensor dependent)
Rise Time< 15 ns (sensor dependent)
Timebase Range5 ns/div to 1 h/div

Internal Calibrator

ParameterValue
Calibrator Source Frequency1.0025 GHz
Calibrator Power Range-40 to +20 dBm

Triggering

ParameterValue
Trigger SourcesChannel 1, Channel 2, External
External Trigger InputBNC, TTL compatible
Trigger ModesAuto, Normal, Free Run, Single-Shot
Trigger SlopePositive or Negative

Physical & Environmental

ParameterValue
Rackmount CompatibilityStandard 19-inch rack-mountable

Performance

ParameterValue
Single-Shot Sampling Rate1 MSa/s per channel
Effective Sampling Rate25 MSa/s (for repetitive signals)
Video BandwidthUp to 30 MHz (sensor dependent)
Timebase Jitter< 50 ps RMS

Display & Scale

ParameterValue
Vertical Scale (Logarithmic)0.1 to 10 dB/div in 1-2-5 sequence
Vertical Scale (Linear)1 nW/div to 100 MW/div

Measurement

ParameterValue
Statistical FunctionsCDF, CCDF, PDF
Automatic Pulse MeasurementsRise time, fall time, pulse width, off-time, period, duty cycle, peak power, average power, pulse power, overshoot, delay, crest factor

Calibrator

ParameterValue
Calibrator Output ConnectorType N (female), front panel
Calibrator VSWR< 1.20 @ 1.0 GHz
Calibrator Power Accuracy (at 0 dBm)±0.065 dB (±1.5%)
Calibrator Power Accuracy (-10 to +10 dBm)±0.09 dB (±2.1%)

Environmental

ParameterValue
Storage Temperature-40°C to +75°C
Relative Humidity95% RH, non-condensing
Operating Altitude4,572 m (15,000 ft)
Non-operating Altitude15,240 m (50,000 ft)

Inputs & Outputs

ParameterValue
Recorder OutputsRear panel BNC connectors, 0 to 10 V into >10 kOhm

Horizontal System

ParameterValue
Timebase Accuracy±0.01%

Display

ParameterValue
Display Resolution (Logarithmic)0.1, 0.01, or 0.001 dB
Display Resolution (Linear)1 to 4 significant digits

Technology

RF Peak Power Analysis

Applications