The Chroma 19073 is a compact, three-in-one electrical safety analyzer combining AC Hipot, DC Hipot, and Insulation Resistance (IR) testing in a single unit. It features Open/Short Check (OSC) capability, a Ground Fault Interrupt (GFI) safety mechanism, and an intuitive interface, making it ideal for testing compliance with UL, CSA, TUV, VDE, and CE standards.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | RS-232, Remote I/O (standard); GPIB (optional) |
| Display | 240 x 64 matrix LCD display |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 115 / 230 V AC ±10%, 50 / 60 Hz |
| Operating Temperature | 0 °C - 40 °C |
| Dimensions (W×H×D) | 285 x 105 x 390 mm |
| Weight | 9 kg |
AC Dielectric Withstand (AC Hipot)
| Parameter | Value |
|---|---|
| AC Hipot Output Voltage Range | 0.05 kV - 5.00 kV AC |
| AC Hipot Voltage Resolution | 2 V |
| AC Hipot Voltage Accuracy | ±(1% of reading + 5 V) |
| AC Hipot Output Frequency Range | 50 Hz / 60 Hz |
| AC Hipot Max Rated Current | 30 mA |
| AC Hipot Current Measurement Range | 0.001 mA - 30.00 mA |
| AC Hipot Current Resolution | 0.001 mA |
| AC Hipot Current Accuracy | ±(1% of reading + 5 counts) |
| AC Hipot Output Waveform | Sine wave |
DC Dielectric Withstand (DC Hipot)
| Parameter | Value |
|---|---|
| DC Hipot Output Voltage Range | 0.05 kV - 6.00 kV DC |
| DC Hipot Voltage Resolution | 2 V |
| DC Hipot Voltage Accuracy | ±(1% of reading + 5 V) |
| DC Hipot Max Rated Current | 10 mA |
| DC Hipot Current Measurement Range | 0.0001 mA - 10.00 mA |
| DC Hipot Current Resolution | 0.0001 mA |
| DC Hipot Current Accuracy | ±(1% of reading + 5 counts) |
| DC Hipot Auto-Discharge Function | Yes (within 0.2 s) |
Insulation Resistance (IR)
| Parameter | Value |
|---|---|
| IR Output Voltage Range | 0.05 kV - 1.00 kV DC |
| IR Voltage Resolution | 2 V |
| IR Voltage Accuracy | ±(1% of reading + 5 V) |
| IR Resistance Measurement Range | 1 MΩ - 50 GΩ |
| IR Max Charging Current | 10 mA |
| IR Resistance Accuracy | ±(5% of reading + 5 counts) for 1 MΩ to 1 GΩ (at ≥ 500 V); ±(10% of reading + 5 counts) for 1 GΩ to 50 GΩ or test voltage < 500 V |
Test Control & Timing
| Parameter | Value |
|---|---|
| Ramp-Up Time Range | 0.1 s - 999 s |
| Dwell Time (Test Time) Range | 0.1 s - 999 s (or continuous) |
| Ramp-Down Time Range | 0 s - 999 s |
| Fast Cut-Off Response Time | 0.4 ms |
| Fast Discharge Time | within 0.2 s |
Safety & Protection Features
| Parameter | Value |
|---|---|
| Ground Fault Interrupt (GFI) Trip Current | 0.5 mA |
| Open/Short Check (OSC) Function | Yes |
| Safety Interlock | Yes |
| Arc Detection | Yes |
| Visual Fail/Pass Indicators | Yes |
| Audible Alarm Output | Yes |
System, Memory & Programming
| Parameter | Value |
|---|---|
| Internal Memory Capacity | 10 groups, 10 steps per group |
| Step Link / Auto-Sequence Capability | Yes |
| Key Lock / Security Password Protection | Yes |
Connectivity & Interfaces
| Parameter | Value |
|---|---|
| Remote I/O (PLC) Interface | Standard |
| RS-232 Interface | Standard |
| GPIB (IEEE-488) Interface | Optional |
Environmental & Compliance
| Parameter | Value |
|---|---|
| Operating Temperature Range | 0 °C - 40 °C |
| Operating Humidity Range | ≤ 80% RH (non-condensing) |
Ground Check (GC)
| Parameter | Value |
|---|---|
| Ground Check Resistance Range | 0.1 Ω to 5.0 Ω |
| Ground Check Resistance Resolution | 0.1 Ω |
Memory & Sequencing
| Parameter | Value |
|---|---|
| Max Test Steps per Sequence | 10 steps per group (10 groups, total 100 steps) |
DC Hipot
| Parameter | Value |
|---|---|
| DC Hipot Ripple | < 20 V (at 6 kV DC, no load) |
| DC Hipot Current Limit Setting Range | 0.0001 mA to 10 mA |
AC Hipot
| Parameter | Value |
|---|---|
| AC Hipot Output Distortion | < 2% (at no load) |
| AC Hipot Current Limit Setting Range | 0.001 mA to 40 mA |
Power Supply
| Parameter | Value |
|---|---|
| Power Consumption | 300 VA max. |
Safety & Protection
| Parameter | Value |
|---|---|
| Zero Crossing Start | Yes |
Performance
| Parameter | Value |
|---|---|
| Output Voltage Line Regulation | ±1% |
| Output Voltage Load Regulation | ±1% |
Arc Detection
| Parameter | Value |
|---|---|
| Arc Detection Current Limit Range | AC: 1 mA to 20 mA / DC: 1 mA to 10 mA |
Insulation Resistance
| Parameter | Value |
|---|---|
| IR Resistance Limit Setting Range | 1 MΩ to 50 GΩ |
Technology
AC/DC/IR Hipot Tester
Applications
Electrical Safety Compliance Testing