The Fluke 1750 Three-Phase Power Quality Recorder is a high-precision, headless power monitoring instrument designed for compliance with IEC 61000-4-30 Class A standards. It automatically records every power quality parameter on all channels continuously, offering threshold-free post-processing analysis. Users configure the device and visualize real-time data wirelessly using a PDA or PC.

Specifications

General

ParameterValue
InterfacesEthernet (100Base-T RJ-45), Bluetooth Class 1, SD Card Slot
DisplayNone (headless design; utilizes wireless PDA or PC as virtual front panel/display)
Calibration Cycle1 year (recommended)

Physical

ParameterValue
Power Supply85 V to 264 V AC, 47 Hz to 63 Hz, or 120 V to 370 V DC; 40 VA maximum
Operating Temperature0 °C to 50 °C
Dimensions (W×H×D)215 mm × 310 mm × 91 mm
Weight3.0 kg

Input Channels & Configuration

ParameterValue
Number of Voltage Inputs5 channels (A/L1, B/L2, C/L3, N, G)
Number of Current Inputs5 channels (A/L1, B/L2, C/L3, N, G)
Phase Configurations SupportedOne Phase Plus Neutral, One Phase IT No Neutral, One Phase Split Phase, Three Phase Wye, Three Phase Delta, Three Phase IT, Three Phase High Leg, Three Phase Open Leg, 2 Element Delta, 2 1/2 Element Wye
Voltage Input CouplingDC coupled
Input Terminals TypeSingle-lead voltage connections and self-identifying current probes

Measurement Ranges & Input Characteristics

ParameterValue
Direct Voltage Range0 to 1000 Vrms (AC or DC)
Transient Voltage Range8000 Vpk
Direct Current Input Range50 mV to 1.414 Vrms with 2 V peak (probe dependent)
Voltage Input Impedance4 MΩ per channel to ground
Current Input Impedance50 kΩ
Maximum Voltage Input1000 Vrms

Measurement Performance & Accuracy

ParameterValue
Mains Frequency Range45 Hz to 65 Hz
PLL Frequency Synchronization Range42.5 Hz to 69 Hz
Voltage Resolution16-bit (for power parameters), 14-bit (for 5 MHz transient sampling)
Sampling Rate (Power Parameters)256 samples per cycle (phase locked to mains)
Sampling Rate (Transient)5 MHz (simultaneous on all voltage channels)
Voltage Measurement Accuracy±0.1% of Vdin (from 10% to 150% of Vdin)
Frequency Measurement Accuracy±10 mHz
Standard ComplianceIEC 61000-4-30 Class A

Power & Harmonic Analysis Functions

ParameterValue
Measured ParametersVoltage, current, active power (P), apparent power (S), reactive power (Q), power factor, frequency, THD, harmonics, interharmonics, flicker, unbalance, transients
Harmonic Measurement BandwidthUp to 50th harmonic
Flicker MeasurementPst and Plt in accordance with IEC 61000-4-15
Interharmonics AnalysisIn accordance with IEC 61000-4-7
Voltage Crest FactorCalculated and logged
Current Crest FactorCalculated and logged

Data Logging, Memory & Visualization

ParameterValue
Internal Storage CapacitySD Memory Card (2 GB standard, removable)
Logging RateEvery cycle, continuously without thresholds
Setup MethodThreshold-free setup; thresholds applied post-collection via PC software
SoftwareFluke Power Analyze software (for data retrieval, analysis, and reporting)
Data Retrieval OptionsVia SD card, Ethernet, or Bluetooth

System Interfaces & Connectivity

ParameterValue
External Synchronization InputGPS time synchronization input (via optional GPS receiver)
Status IndicatorsLEDs for Power, Status, LAN, Bluetooth, Card, Phase/Voltage Channels

Power Supply & Safety Compliance

ParameterValue
Safety Category RatingCAT IV 600 V / CAT III 1000 V
Safety StandardsIEC/EN 61010-1
EMC StandardsEN 61326-1
Internal Backup BatteryNiMH battery, >5 minutes backup, typical recharge time 4 hours

Physical & Environmental Specifications

ParameterValue
Storage Temperature Range-20 °C to 50 °C (with battery); -20 °C to 60 °C (without battery)
Operating Humidity Range10% to 90% RH non-condensing
Enclosure Protection ClassIP30

Accuracy & Performance

ParameterValue
Current Accuracy (Instrument Only)±0.1% of reading ± 0.02% of range
Active Power Accuracy±0.2% of reading + sensor accuracy
Phase Angle Accuracy (Voltage to Voltage)±0.05°
Phase Angle Accuracy (Voltage to Current)±0.15° (instrument only)
Power Factor Accuracy±0.002 + sensor accuracy
Clock Accuracy (Internal)±1 s per day
Clock Accuracy (GPS Synchronized)±16.7 µs (relative to GPS UTC)

Power & Battery

ParameterValue
Power Consumption40 VA max.
Internal Battery ChemistryNiMH (Nickel-Metal Hydride)
Battery Charge Time4 hours (with instrument turned off)
Battery Ride-Through Time5 minutes minimum

Environmental

ParameterValue
Maximum Operating Altitude2000 m (CAT IV 600 V / CAT III 1000 V), up to 3000 m (derated to CAT III 600 V / CAT II 1000 V)

Measurement Resolution

ParameterValue
A/D Converter Resolution24-bit (continuous sampling on all channels)
Transient Sampling Resolution14-bit

Connectivity

ParameterValue
Bluetooth Class & RangeBluetooth v1.2 Class 1, up to 100 m (328 ft) typical range
Ethernet Port SpecificationRJ-45 (10/100 Base-T with Auto MDIX)

Measurement Characteristics

ParameterValue
Input Range SelectionFully automatic ranging
Total Simultaneous Channels9 channels (4 voltage and 5 current)

Technology

Digital power quality auditing and transient analysis

Applications

Power quality auditing, disturbance analysis, energy assessments, and compliance testing

Looking for the Fluke 1750?

Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.

Selling this kind of equipment? Sell with us