The Fluke Networks DSX2-8000 CableAnalyzer is a premier copper cabling certification solution designed for installers and network owners. Part of the Versiv cabling certification product family, it provides rapid, precise testing up to Category 8 and Class I/II standards with Level 2G / Level VI accuracy. It features dual-band Wi-Fi, the LinkWare Live cloud testing workflow platform, and advanced diagnostics like High Definition Time Domain Crosstalk (HDTDX) and Reflectometry (HDTDR) to accelerate project execution and troubleshooting.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | USB 2.0 Micro-B, USB 2.0 Type A, RJ-45 Ethernet (10/100 BASE-TX), Wi-Fi (IEEE 802.11 a/b/g/n dual-band) |
| Display | 5.7 in (14.5 cm) capacitive LCD touchscreen with 800 x 480 resolution |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 7.2 V Lithium-ion battery pack; External AC adapter: 100 V to 240 VAC, 50-60 Hz input, 15 VDC, 2 A output |
| Operating Temperature | 0 °C to 45 °C |
| Dimensions (W×H×D) | 133.3 mm × 66.7 mm × 279.4 mm (with DSX-8000 module and battery installed) |
| Weight | 1.28 kg |
Core Signal and Electrical Performance
| Parameter | Value |
|---|---|
| Frequency Range | 1 MHz to 2000 MHz |
| ANSI/TIA Accuracy Level | Level 2G (ANSI/TIA-1152-A) |
| IEC Accuracy Level | Level VI (IEC 61935-1) |
| Supported Cable Types | Shielded and unshielded twisted pair (UTP, ScTP, FTP, SSTP) |
| Input Overvoltage Protection | Protected against continuous telco voltages and 100 mA over-current |
Measurement Capabilities and Timing
| Parameter | Value |
|---|---|
| Autotest Speed - Category 6A | 8 seconds |
| Autotest Speed - Category 8 | 16 seconds |
| Maximum Cable Length (Propagation Delay) | 150 m (490 ft) |
| Length Resolution | 0.1 m |
| Propagation Delay Resolution | 1 ns |
| Delay Skew Resolution | 1 ns |
| DC Loop Resistance Range | 0 Ω to 540 Ω |
| DC Loop Resistance Resolution | 0.1 Ω |
| DC Resistance Unbalance Resolution | 0.1 Ω |
| NVP Range | 50% to 99.9% |
| Diagnostics / Troubleshooting | HDTDX (High Definition Time Domain Crosstalk), HDTDR (High Definition Time Domain Reflectometry) |
Connectivity, Ports, and Interfaces
| Parameter | Value |
|---|---|
| USB Ports | 1 x Type A (Host), 1 x Micro-B (Device) |
| Auxiliary Interface Ports | 3.5 mm stereo headset jack, RJ-45 Ethernet port |
User Interface and Software Control
| Parameter | Value |
|---|---|
| Internal Storage Capacity (with graphs) | 5,000 results |
| Internal Storage Capacity (without graphs) | 12,000 results |
| Cloud Integration | LinkWare Live cloud service integration via Wi-Fi or Ethernet |
| PC Analysis Software | LinkWare PC software |
| Supported Languages | English, French, German, Spanish, Portuguese, Italian, Japanese, Simplified Chinese, Traditional Chinese, Korean, Russian |
Power and Electrical Specifications
| Parameter | Value |
|---|---|
| Battery Chemistry | Lithium-ion |
| Typical Battery Runtime | 8 hours |
| Battery Recharge Time | 4 hours (from 10% to 90% charge, with tester powered off) |
Physical and Mechanical Attributes
| Parameter | Value |
|---|---|
| Enclosure Design | Rugged overmold design for heavy-duty field environments |
Environmental and Compliance Standards
| Parameter | Value |
|---|---|
| Storage Temperature Range | -20 °C to +60 °C |
| Relative Humidity Range | 0% to 90% (non-condensing) |
| Maximum Operating Altitude | 4,000 m (13,123 ft) |
| Maximum Storage Altitude | 4,600 m (15,000 ft) |
| Calibration Interval | 1 year (recommended) |
| Vibration Standard Compliance | Meets MIL-PRF-28800F Class 3 requirements |
Configurations, Options, and Accessories
| Parameter | Value |
|---|---|
| TIA Cabling Standards | Category 3, 4, 5, 5e, 6, 6A, 8 per TIA-568.2-D |
| ISO/IEC Cabling Standards | Class C, D, E, Ea, F, Fa, I/II per ISO/IEC 11801 |
Measurements
| Parameter | Value |
|---|---|
| DC Loop Resistance Accuracy | ± (1 Ω + 1 %) |
| DC Resistance Unbalance Accuracy | ± (0.15 Ω + 1 %) |
| Shield Continuity Test Method | Patented AC measurement (localizes shield faults with distance) |
| TCL and ELTCTL Measurement Support | Up to 2000 MHz |
| CDNEXT and CMACRF Measurement Support | Up to 2000 MHz |
| Resistance Unbalance Capability | Measures within-pair and pair-to-pair DC resistance unbalance |
Wireless Connectivity
| Parameter | Value |
|---|---|
| Integrated Wi-Fi | IEEE 802.11 a/b/g/n (2.4 GHz and 5 GHz) |
Power
| Parameter | Value |
|---|---|
| AC Charger Input | 100 V AC to 240 V AC, 50 Hz to 60 Hz |
| AC Charger Output | 15 V DC, 2 A |
Environmental
| Parameter | Value |
|---|---|
| Pollution Degree Rating | Pollution Degree 2 |
| Shock and Vibration standard | Meets MIL-PRF-28800F Class 3 requirements |
Performance
| Parameter | Value |
|---|---|
| Autotest Speed - Category 5e/6 | 7 seconds |
Connectivity & Communication
| Parameter | Value |
|---|---|
| Talkset Interface | Full-duplex digital audio over twisted pair |
Measurement Capabilities
| Parameter | Value |
|---|---|
| Supported Coaxial Impedance | 50 Ω, 75 Ω, 93 Ω (with optional adapters) |
| Propagation Delay Range | 0 ns to 4000 ns (dual-ended) / 0 ns to 4000 ns (single-ended) |
| Delay Skew Range | 0 ns to 125 ns |
Display
| Parameter | Value |
|---|---|
| Display Resolution | 800 × 480 pixels |
Compliance & Safety
| Parameter | Value |
|---|---|
| Safety Compliance | IEC 61010-1: Overvoltage Category None, Pollution Degree 2; IEC 61010-30: 30 V rms max |
| EMC Compliance | IEC 61326-1: Portable; CISPR 11: Group 1, Class A; FCC Part 15 Class A |
Power & Battery
| Parameter | Value |
|---|---|
| Battery Charging Temperature Range | 0 °C to 40 °C |
Physical & Durability
| Parameter | Value |
|---|---|
| Adapter Connector Life | Typical > 5,000 cycles |
Technology
Copper Twisted Pair Cabling Certification
Applications
Category 5e/6/6A/8 and Class C/D/E/Ea/F/Fa/I/II cabling certification