The JDSU OLP-5 is a rugged, pocket-sized optical power meter designed for universal singlemode and multimode loss testing and systems power measurements. It features TWINtest automatic attenuation measurement and Auto-lambda wavelength detection for simplified, efficient testing in a compact, shock-proof format.
Specifications
General
| Parameter | Value |
|---|---|
| Display | LCD |
| Auto Power-Off | After approx. 20 minutes |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 2x 1.5 V AA batteries (dry) or NiMH/NiCd cells |
| Operating Temperature | -10 to +55 °C |
Optical Specifications
| Parameter | Value |
|---|---|
| Detector Type | Germanium (Ge) |
| Power Measurement Range | -60 to +5 dBm |
| Calibrated Wavelengths | 850, 1300, 1310, 1550 nm |
| Automatic Attenuation Measurement | TWINtest at 850/1300 nm or 1310/1550 nm |
| Wavelength Auto-Recognition | Auto-lambda automatic wavelength detection |
Measurement and Display
| Parameter | Value |
|---|---|
| Controls | 3-button operation |
Interfaces and Connectors
| Parameter | Value |
|---|---|
| Optical Connector Interface | Universal push-pull adapter (UPP) |
Power and Battery
| Parameter | Value |
|---|---|
| Battery Type | 2x AA (Mignon) 1.5V dry batteries or NiMH/NiCd cells |
| Battery Operating Time | > 130 hours |
Physical Specifications
| Parameter | Value |
|---|---|
| Design Features | Rugged, portable, and shock-proof design |
Compliance and Accessories
| Parameter | Value |
|---|---|
| Recommended Calibration Cycle | 3 years |
| Included Accessories | Two Mignon AA 1.5V batteries, operating manual, nylon belt pouch |
Environmental
| Parameter | Value |
|---|---|
| Storage Temperature | -40 to +70 °C |
Performance
| Parameter | Value |
|---|---|
| Wavelength Range | 780 to 1600 nm |
| Max Permitted Input Level | +15 dBm |
| Intrinsic Uncertainty | ±0.2 dB |
| Display Resolution | 0.01 dB / 0.01 dBm |
Display
| Parameter | Value |
|---|---|
| Display Units | dB, dBm, W (mW, µW, nW, pW) |
Technology
Optical Power Measurement
Applications
Fiber Optic Testing