T-BERD/MTS-4000 FiberComplete

JDSUFiberoptic Test Tools, Sets

The JDSU T-BERD/MTS-4000 FiberComplete is an all-in-one fiber optic testing solution designed for characterization of fiber links. It is the first platform to integrate automated bi-directional insertion loss (IL), bi-directional optical return loss (ORL), distance, and OTDR or Fault Finder capabilities using a single fiber connection and one-button operation. Configured as a modular handheld platform, it is highly optimized for Metro-Access (MA) and Metro-PON (MP) testing workflows.

Specifications

General

ParameterValue
InterfacesUSB 2.0 (2× Host, 1× Device), RJ-45 Ethernet (10/100 Mbps)
Display7-inch color TFT touchscreen (800 × 480 WVGA)

Physical

ParameterValue
Power Supply100-240 V AC, 50-60 Hz (via external AC/DC adapter, 19 V DC output)
Operating Temperature-20 to 50
Dimensions (W×H×D)220 × 150 × 70
Weight1.7

FiberComplete System Performance

ParameterValue
Integrated MeasurementsBi-directional Insertion Loss (IL), bi-directional Optical Return Loss (ORL), distance, and OTDR/Fault Finder
Test AutomationOne connection, one-touch automated measurements
Continuity CheckReal-time continuity check and product pairing using the fiber under test
Troubleshooting ModeFault Finder mode for immediate troubleshooting
Workflow AnalysisPass/Fail indications and direct report generation
Threshold ConfigurationsPredefined and user-defined thresholds
Initial ReferencingStep-by-step wizard for initial IL/ORL test referencing

Optical Return Loss (ORL) Specifications

ParameterValue
ORL Measurement MethodOptical Continuous Wave Reflectometry (OCWR)
ORL Measurement Range0 to 55 dB
ORL Measurement Accuracy±0.5 dB
IL Measurement Accuracy±0.15 dB

Metro-Access (MA) OTDR Module (TB4T-FCOMP2-MA / MTS4T-FCOMP2-MA)

ParameterValue
Metro-Access (MA) OTDR Wavelengths1310 nm, 1550 nm
Metro-Access (MA) Dynamic Range37 dB (1310 nm), 35 dB (1550 nm)
Metro-Access (MA) FiberComplete Wavelengths1310 nm, 1550 nm

Metro-PON (MP) OTDR Module (TB4T-FCOMP3-MP49 / MTS4T-FCOMP3-MP49)

ParameterValue
Metro-PON (MP) OTDR Wavelengths1310 nm, 1490 nm, 1550 nm
Metro-PON (MP) FiberComplete Wavelengths1310 nm, 1490 nm, 1550 nm

Optical Source & Power Meter (Integrated)

ParameterValue
Integrated Power MeterBroadband power meter included
Integrated Light SourceContinuous Wave (CW) light source
Fiber Type CompatibilitySingle-mode (SM)

Fiber Inspection Probe Interface

ParameterValue
Fiber Connector InspectionPass/Fail connector inspection software (digital probe available separately)

Package-Specific Adapters & Accessories (North American - TB4T)

ParameterValue
North American Package Optical AdapterSC/PC interchangeable adapter
North American Package Standard AccessoriesNon-reflective terminations for zero ORL referencing, SC mating sleeves, SC/PC to SC/APC 3 m SM jumper, SC/PC to SC/PC 3 m SM jumper, Glove carrying case

Package-Specific Adapters & Accessories (Global - MTS4T)

ParameterValue
Global Package Optical AdapterFC/PC interchangeable adapter
Global Package Standard AccessoriesNon-reflective terminations for zero ORL referencing, FC mating sleeves, FC/PC to FC/APC 3 m SM jumper, FC/PC to FC/PC 3 m SM jumper, Glove carrying case

Software & Data Management

ParameterValue
Results ManagementFiber or Cable results management structure
PC Post-Processing SoftwareFiberTrace (OFS-100) and FiberCable (OFS-200) compatible

Platform General Specifications

ParameterValue
Display Size7 in (178 mm) diagonal
Battery Operating LifeUp to 8 hours under typical operating conditions
Battery TypeRechargeable Lithium-ion (Li-ion)
Storage Temperature Range-20 to +60 °C

FiberComplete Module Performance

ParameterValue
Bidirectional Test Time< 40 s

General / Safety

ParameterValue
Laser Safety ClassClass 1 (IEC 60825-1)

OTDR Performance

ParameterValue
Metro-Access (MA) Event Dead Zone0.9 m typical
Metro-Access (MA) Attenuation Dead Zone4 m typical
Metro-PON (MP) Event Dead Zone0.8 m typical
Metro-PON (MP) Attenuation Dead Zone4 m typical
Distance Accuracy±(1 m + 10^-5 × distance + sampling resolution)
Sampling Resolution4 cm minimum
Number of Data PointsUp to 128,000
Metro-Access (MA) Pulse Widths3 ns to 20 µs
Metro-PON (MP) Pulse Widths3 ns to 20 µs
Metro-Access (MA) Distance Range0.1 to 260 km
Metro-PON (MP) Distance Range0.1 to 260 km

Integrated Power Meter

ParameterValue
Integrated Power Meter Calibrated Wavelengths1310, 1490, 1550, 1625, 1650 nm
Integrated Power Meter Measurement Range-2 to -50 dBm
Integrated Power Meter Accuracy±0.25 dB

Integrated Light Source

ParameterValue
Integrated Light Source Output Power-3.5 dBm typical
Integrated Light Source Stability (24 h)±0.1 dB

Insertion Loss (IL) Performance

ParameterValue
IL Measurement Resolution0.01 dB

Optical Return Loss (ORL) Performance

ParameterValue
ORL Display Resolution0.01 dB

Visual Fault Locator (VFL)

ParameterValue
Visual Fault Locator (VFL) Wavelength650 nm
Visual Fault Locator (VFL) Output Power1 mW (0 dBm)
Visual Fault Locator (VFL) Laser ClassClass 2 (IEC 60825-1)

Environmental

ParameterValue
Operating Humidity95% non-condensing

Data & Results Management

ParameterValue
Data Saving FormatsBellcore/Telcordia GR-196-CORE OTDR (.sor), PDF, TXT

Talk Set Option

ParameterValue
Talk Set Wavelength1550 nm or 1625 nm (option dependent)
Talk Set Dynamic Range45 dB

Technology

Fiber Optic Testing Platform

Applications

Fiber Optic Network Installation, Commissioning, and Maintenance