- Home
- Categories
- Test equipment
- Fiber Optics Comm
- Fiberoptic Test Tools, Sets
- T-BERD/MTS-4000 FiberComplete
The JDSU T-BERD/MTS-4000 FiberComplete is an all-in-one fiber optic testing solution designed for characterization of fiber links. It is the first platform to integrate automated bi-directional insertion loss (IL), bi-directional optical return loss (ORL), distance, and OTDR or Fault Finder capabilities using a single fiber connection and one-button operation. Configured as a modular handheld platform, it is highly optimized for Metro-Access (MA) and Metro-PON (MP) testing workflows.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | USB 2.0 (2× Host, 1× Device), RJ-45 Ethernet (10/100 Mbps) |
| Display | 7-inch color TFT touchscreen (800 × 480 WVGA) |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 100-240 V AC, 50-60 Hz (via external AC/DC adapter, 19 V DC output) |
| Operating Temperature | -20 to 50 |
| Dimensions (W×H×D) | 220 × 150 × 70 |
| Weight | 1.7 |
FiberComplete System Performance
| Parameter | Value |
|---|---|
| Integrated Measurements | Bi-directional Insertion Loss (IL), bi-directional Optical Return Loss (ORL), distance, and OTDR/Fault Finder |
| Test Automation | One connection, one-touch automated measurements |
| Continuity Check | Real-time continuity check and product pairing using the fiber under test |
| Troubleshooting Mode | Fault Finder mode for immediate troubleshooting |
| Workflow Analysis | Pass/Fail indications and direct report generation |
| Threshold Configurations | Predefined and user-defined thresholds |
| Initial Referencing | Step-by-step wizard for initial IL/ORL test referencing |
Optical Return Loss (ORL) Specifications
| Parameter | Value |
|---|---|
| ORL Measurement Method | Optical Continuous Wave Reflectometry (OCWR) |
| ORL Measurement Range | 0 to 55 dB |
| ORL Measurement Accuracy | ±0.5 dB |
| IL Measurement Accuracy | ±0.15 dB |
Metro-Access (MA) OTDR Module (TB4T-FCOMP2-MA / MTS4T-FCOMP2-MA)
| Parameter | Value |
|---|---|
| Metro-Access (MA) OTDR Wavelengths | 1310 nm, 1550 nm |
| Metro-Access (MA) Dynamic Range | 37 dB (1310 nm), 35 dB (1550 nm) |
| Metro-Access (MA) FiberComplete Wavelengths | 1310 nm, 1550 nm |
Metro-PON (MP) OTDR Module (TB4T-FCOMP3-MP49 / MTS4T-FCOMP3-MP49)
| Parameter | Value |
|---|---|
| Metro-PON (MP) OTDR Wavelengths | 1310 nm, 1490 nm, 1550 nm |
| Metro-PON (MP) FiberComplete Wavelengths | 1310 nm, 1490 nm, 1550 nm |
Optical Source & Power Meter (Integrated)
| Parameter | Value |
|---|---|
| Integrated Power Meter | Broadband power meter included |
| Integrated Light Source | Continuous Wave (CW) light source |
| Fiber Type Compatibility | Single-mode (SM) |
Fiber Inspection Probe Interface
| Parameter | Value |
|---|---|
| Fiber Connector Inspection | Pass/Fail connector inspection software (digital probe available separately) |
Package-Specific Adapters & Accessories (North American - TB4T)
| Parameter | Value |
|---|---|
| North American Package Optical Adapter | SC/PC interchangeable adapter |
| North American Package Standard Accessories | Non-reflective terminations for zero ORL referencing, SC mating sleeves, SC/PC to SC/APC 3 m SM jumper, SC/PC to SC/PC 3 m SM jumper, Glove carrying case |
Package-Specific Adapters & Accessories (Global - MTS4T)
| Parameter | Value |
|---|---|
| Global Package Optical Adapter | FC/PC interchangeable adapter |
| Global Package Standard Accessories | Non-reflective terminations for zero ORL referencing, FC mating sleeves, FC/PC to FC/APC 3 m SM jumper, FC/PC to FC/PC 3 m SM jumper, Glove carrying case |
Software & Data Management
| Parameter | Value |
|---|---|
| Results Management | Fiber or Cable results management structure |
| PC Post-Processing Software | FiberTrace (OFS-100) and FiberCable (OFS-200) compatible |
Platform General Specifications
| Parameter | Value |
|---|---|
| Display Size | 7 in (178 mm) diagonal |
| Battery Operating Life | Up to 8 hours under typical operating conditions |
| Battery Type | Rechargeable Lithium-ion (Li-ion) |
| Storage Temperature Range | -20 to +60 °C |
FiberComplete Module Performance
| Parameter | Value |
|---|---|
| Bidirectional Test Time | < 40 s |
General / Safety
| Parameter | Value |
|---|---|
| Laser Safety Class | Class 1 (IEC 60825-1) |
OTDR Performance
| Parameter | Value |
|---|---|
| Metro-Access (MA) Event Dead Zone | 0.9 m typical |
| Metro-Access (MA) Attenuation Dead Zone | 4 m typical |
| Metro-PON (MP) Event Dead Zone | 0.8 m typical |
| Metro-PON (MP) Attenuation Dead Zone | 4 m typical |
| Distance Accuracy | ±(1 m + 10^-5 × distance + sampling resolution) |
| Sampling Resolution | 4 cm minimum |
| Number of Data Points | Up to 128,000 |
| Metro-Access (MA) Pulse Widths | 3 ns to 20 µs |
| Metro-PON (MP) Pulse Widths | 3 ns to 20 µs |
| Metro-Access (MA) Distance Range | 0.1 to 260 km |
| Metro-PON (MP) Distance Range | 0.1 to 260 km |
Integrated Power Meter
| Parameter | Value |
|---|---|
| Integrated Power Meter Calibrated Wavelengths | 1310, 1490, 1550, 1625, 1650 nm |
| Integrated Power Meter Measurement Range | -2 to -50 dBm |
| Integrated Power Meter Accuracy | ±0.25 dB |
Integrated Light Source
| Parameter | Value |
|---|---|
| Integrated Light Source Output Power | -3.5 dBm typical |
| Integrated Light Source Stability (24 h) | ±0.1 dB |
Insertion Loss (IL) Performance
| Parameter | Value |
|---|---|
| IL Measurement Resolution | 0.01 dB |
Optical Return Loss (ORL) Performance
| Parameter | Value |
|---|---|
| ORL Display Resolution | 0.01 dB |
Visual Fault Locator (VFL)
| Parameter | Value |
|---|---|
| Visual Fault Locator (VFL) Wavelength | 650 nm |
| Visual Fault Locator (VFL) Output Power | 1 mW (0 dBm) |
| Visual Fault Locator (VFL) Laser Class | Class 2 (IEC 60825-1) |
Environmental
| Parameter | Value |
|---|---|
| Operating Humidity | 95% non-condensing |
Data & Results Management
| Parameter | Value |
|---|---|
| Data Saving Formats | Bellcore/Telcordia GR-196-CORE OTDR (.sor), PDF, TXT |
Talk Set Option
| Parameter | Value |
|---|---|
| Talk Set Wavelength | 1550 nm or 1625 nm (option dependent) |
| Talk Set Dynamic Range | 45 dB |
Technology
Fiber Optic Testing Platform
Applications
Fiber Optic Network Installation, Commissioning, and Maintenance
Looking for the JDSU T-BERD/MTS-4000 FiberComplete?
Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.
Selling this kind of equipment? Sell with us