The Keysight 34972A is a high-performance Data Acquisition and Switch Unit featuring a built-in 6.5-digit digital multimeter (DMM). Equipped with modern USB 2.0 and 10/100 LAN interfaces, it provides flexible remote connectivity, built-in LXI Web interface, and direct data-logging capabilities to a USB flash drive without requiring a PC connection.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | USB 2.0 (Device), LAN (10/100 Base-T, LXI Class C), USB Host (Front panel) |
| Display | Vacuum fluorescent display (VFD) |
Physical
| Parameter | Value |
|---|---|
| Operating Temperature | 0 °C to 55 °C |
| Weight | 3.6 kg |
Mainframe System Characteristics
| Parameter | Value |
|---|---|
| Number of Card Slots | 3 |
| Built-in DMM Resolution | 6.5 digits |
| Maximum Scan Rate | 250 channels/s |
| Internal Memory Capacity | 50,000 readings (with timestamp in non-volatile memory) |
| Non-volatile Memory Retention | 10 years (battery-backed) |
| Internal Clock and Calendar Accuracy | Battery-backed real-time clock |
| USB Flash Drive Port Support | Yes (front panel USB 2.0 port) |
Internal DMM Measurement Functions
| Parameter | Value |
|---|---|
| DC Voltage Ranges | 100 mV, 1 V, 10 V, 100 V, 300 V |
| DC Voltage Best Resolution | 100 nV |
| AC Voltage Ranges | 100 mV, 1 V, 10 V, 100 V, 300 V (AC-coupled True RMS) |
| AC Voltage Frequency Range | 3 Hz to 300 kHz |
| DC Current Ranges | 10 mA, 100 mA, 1 A |
| AC Current Ranges | 10 mA, 100 mA, 1 A |
| 2-wire Resistance Ranges | 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ, 1 MΩ, 10 MΩ, 100 MΩ |
| 4-wire Resistance Ranges | 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ, 1 MΩ, 10 MΩ, 100 MΩ |
| Frequency and Period Range | 3 Hz to 300 kHz |
| Thermocouple Types Supported | B, E, J, K, N, R, S, T |
| RTD Types Supported | PT100, D100, F100 (α = 0.00385 or 0.00392) |
| Thermistor Types Supported | 2.2 kΩ, 5 kΩ, 10 kΩ |
| Maximum Input Voltage Rating | 300 V peak on any channel (module dependent) |
| Input Impedance (DC Voltage) | 10 MΩ or > 10 GΩ (selectable for 100 mV, 1 V, 10 V ranges) |
| Shunt Resistance (Current Ranges) | 5 Ω (for 10 mA, 100 mA), 0.1 Ω (for 1 A) |
System Speed and Throughput
| Parameter | Value |
|---|---|
| Scan Speed to Internal Memory | up to 250 channels/s |
| Scan Speed to LAN Port | up to 250 channels/s |
| Scan Speed to USB Port | up to 250 channels/s |
| Single Channel Measurement Rate | up to 600 rdgs/s (to internal memory) |
Supported Plug-In Modules and Switching
| Parameter | Value |
|---|---|
| Multiplexer Module Options | 34901A (20-ch), 34902A (16-ch high speed), 34908A (40-ch single-ended) |
| Matrix Module Options | 34904A (4x8 matrix) |
| General Purpose Switch / Actuator Modules | 34903A (20-ch SPDT) |
| RF and Microwave Multiplexer Modules | 34905A (Dual 1:4 2 GHz 50 Ω), 34906A (Dual 1:4 2 GHz 75 Ω) |
| Multifunction Modules | 34907A (Digital I/O, D/A, Totalizer) |
| Maximum System Channel Capacity | 120 single-ended channels (using three 34908A modules) |
| Maximum Voltage Switching Capacity | 300 V (module dependent) |
Connectivity and Instrument Control
| Parameter | Value |
|---|---|
| LAN Interface Speed | 10/100 Base-T |
| Built-in Web Server Interface | Yes (Graphical Web Interface for monitoring and control) |
| Command Language Compatibility | SCPI-1991, Agilent 34970A compatible |
| Virtual Front Panel Support | Yes (via web browser) |
Triggering and Synchronization
| Parameter | Value |
|---|---|
| Alarm Relay Output Interface | 4 physical TTL alarm outputs on rear panel |
| Channel-to-Channel Delay Range | 0 to 60 seconds (1 ms resolution) |
Physical Characteristics
| Parameter | Value |
|---|---|
| Rack Mount Kit Availability | Optional (34190A, 34191A, 34194A) |
Environmental Specifications
| Parameter | Value |
|---|---|
| Operating Temperature Range | 0 °C to 55 °C |
| Storage Temperature Range | -40 °C to 70 °C |
Safety and Regulatory Standards
| Parameter | Value |
|---|---|
| Electrical Safety Standards | Conforms to CSA C22.2 No. 61010-1, EN 61010-1, UL 61010-1 |
| Electromagnetic Compatibility (EMC) | Conforms to EN 61326-1, IEC 61326-1 |
Measurement Technology
| Parameter | Value |
|---|---|
| A/D Converter Type | Multi-slope III |
| Input Bias Current | < 30 pA at 25 °C |
| AC Crest Factor | 5:1 at full scale |
Noise Rejection
| Parameter | Value |
|---|---|
| Normal Mode Rejection (NMRR) | 60 dB at 50/60 Hz ± 0.1% (for 1 PLC or greater) |
| Common Mode Rejection (CMRR) | 140 dB at DC; 70 dB at 50/60 Hz (with 1 kΩ LO lead unbalance) |
Measurement Accuracy
| Parameter | Value |
|---|---|
| DC Voltage 10 V Range 1-Year Accuracy | ±(0.0035% of reading + 0.0005% of range) |
| AC Voltage 10 Hz - 20 kHz 1-Year Accuracy | ±(0.06% of reading + 0.03% of range) |
| Resistance 10 kΩ Range 1-Year Accuracy | ±(0.010% of reading + 0.001% of range) |
Environmental & Safety
| Parameter | Value |
|---|---|
| Pollution Degree | Pollution Degree 2 |
Measurement Capabilities
| Parameter | Value |
|---|---|
| DC Current Best Resolution | 10 nA |
| Resistance Best Resolution | 100 µΩ |
Software & Control
| Parameter | Value |
|---|---|
| Included Software | Keysight BenchLink Data Logger |
Technology
Data Acquisition & Switching
Applications
Precision multi-channel temperature logging, automated electronic test, and system monitoring