The Keysight (formerly HP) 3764A is a high-performance digital transmission analyzer designed for comprehensive error performance testing of telecom and digital transmission systems. It operates primarily at 140 Mb/s with features including pattern generation and error detection at both coded and binary interfaces. Equipped with an HP-IB interface as standard, the analyzer is available with options for multiple CEPT bit-rates (Option 001) and jitter generation/measurement (Option 002), making it highly versatile for field installation, maintenance, development, and manufacturing applications.

Specifications

General

ParameterValue
InterfacesHP-IB (GPIB)
DisplayDual red LED numeric displays (5-digit for Results, 4-digit for Time) and discrete LED status indicators
Measurement PresetsOne-key measurement setup using presets
Form FactorPortable single-unit construction
Data LoggingSupported

Physical

ParameterValue
Operating Temperature0 to +55 °C
Dimensions (W×H×D)425 mm × 177 mm × 498 mm
Weight19

Transmitter (Generator)

ParameterValue
Internal Clock Frequency139.264 MHz
Offset Clocks±15 ppm
External Clock Input Range139.264 MHz (and 2.048, 8.448, 34.368 MHz with Option 001)
Coded Data OutputCMI format at 139.264 Mb/s
Binary Data Outputs139.264 Mb/s (and 2.048, 8.448, 34.368 Mb/s with Option 001)
Output Signal LevelsECL levels
Output Impedance75 ohms unbalanced
Test Patterns (PRBS)2^23 - 1
Programmable Word Length1 to 16-bit fully programmable
Alternate Word CapabilityTwo 1 to 8-bit programmable words, crossover rate controlled by external signal
AIS Pattern GenerationAll ones pattern

Receiver

ParameterValue
Binary Clock Input Range139.264 MHz (and 2.048, 8.448, 34.368 MHz with Option 001)
Input Impedance75 ohms
Input Coupling ModesTerminated mode, Monitor mode
Binary Input FormatsRZ, NRZ
Input Signal LevelsECL levels
External Error InputECL levels

Measurement & Analysis

ParameterValue
Error Performance Parameters% Availability, % ER ≤ N, % EFS
Error Types MeasuredError Ratio, Error Count, Error Seconds, Error Free Seconds

Options & Configurations

ParameterValue
Option 001 - CEPT Rates2, 8, 34, and 140 Mb/s measurements
Option 002 - Jitter MeasurementsJitter generation and timing jitter measurement at 140 Mb/s

Environmental

ParameterValue
Storage Temperature-40 to +75 °C

Power Requirements

ParameterValue
Power Consumption180 VA maximum

System & Control

ParameterValue
Standard Remote InterfaceHP-IB (IEEE-488)

Transmitter Clock

ParameterValue
Internal Clock Accuracy±10 ppm

Receiver / Measurement

ParameterValue
CCITT G.821 Analysis ParametersErrored Seconds (ES), Severely Errored Seconds (SES), Degraded Minutes (DM), and Unavailable Seconds (UAS)

Technology

PDH (Plesiochronous Digital Hierarchy)

Applications