The Keysight (Agilent HP) 4275A is a multi-frequency, high-performance LCR meter designed for precision component testing in the high-frequency range from 10 kHz to 10 MHz. Featuring a basic accuracy of 0.1% and a flexible four-terminal pair configuration, the 4275A supports multi-spot test frequencies, adjustable test signal levels, and comprehensive secondary parameter calculations, making it ideal for both laboratory research and automated production environments.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | HP-IB (GPIB) (Option 101), External Trigger Input (Rear BNC), DC Bias Monitor Output (Rear BNC), External DC Bias Inputs (Rear panel) |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 100 V / 120 V / 220 V (±10%), 240 V (+5% to -10%), 48 to 66 Hz, <=135 VA |
| Operating Temperature | 0 to 55 °C |
| Dimensions (W×H×D) | 425.5 mm × 177 mm × 498 mm |
| Weight | 15 kg |
| Cooling | Forced air by built-in fan |
Measurement Functions
| Parameter | Value |
|---|---|
| Primary Parameters | L, C, |Z| |
| Secondary Parameters | D, Q, ESR, G, X, B, Phase Angle |
| Equivalent Circuit Modes | Auto, Series, Parallel |
| Ranging Modes | Auto, Manual |
| Deviation Measurement Modes | Difference (Δ), Percent Difference (Δ%) |
| Test Terminals Configuration | Four-terminal pair configuration with guard terminal |
| Parameter Combinations | L-D, L-Q, L-R, L-G, C-D, C-Q, C-R, C-G, |Z|-theta, R-X, G-B |
Test Signal
| Parameter | Value |
|---|---|
| Test Frequency Range | 10 kHz to 10 MHz |
| Standard Spot Frequencies | 10 kHz, 20 kHz, 40 kHz, 100 kHz, 200 kHz, 400 kHz, 1 MHz, 2 MHz, 4 MHz, 10 MHz |
| Test Signal Level Range | 1 mV to 1 Vrms |
| Test Signal Level Control | Continuously variable in 3 ranges |
| Frequency Accuracy | ±0.01% |
| Source Impedance | 100 Ω nominal |
User Interface & Display
| Parameter | Value |
|---|---|
| Self Test | Front panel initiated self-test diagnostics |
Input & Output
| Parameter | Value |
|---|---|
| DC Bias Monitor | Bias voltage monitor output on BNC connector for both internal and external biases |
Measurement Speed & Triggering
| Parameter | Value |
|---|---|
| Trigger Modes | Internal, External, Manual |
| Measurement Speed Modes | Normal, Fast |
Measurement Accuracy
| Parameter | Value |
|---|---|
| Basic Accuracy | 0.1% |
Measurement Ranges
| Parameter | Value |
|---|---|
| Capacitance Range (C) | 0.01 fF to 199.99 µF |
| Inductance Range (L) | 0.01 nH to 19.999 H |
| Impedance Range (|Z|) | 0.01 mΩ to 19.999 MΩ |
| Resistance Range (R, ESR) | 0.01 mΩ to 19.999 MΩ |
| Reactance Range (X) | 0.01 mΩ to 19.999 MΩ |
| Dissipation Factor Range (D) | 0.0001 to 9.900 |
| Quality Factor Range (Q) | 0.01 to 9900 |
| Conductance Range (G) | 0.01 nS to 19.999 S |
| Susceptance Range (B) | 0.01 nS to 19.999 S |
| Phase Angle Range | -180.00° to +180.00° |
Correction & Calibration
| Parameter | Value |
|---|---|
| Zero Correction | Open and short circuit compensation |
System Options
| Parameter | Value |
|---|---|
| Option 001 | Internal DC Bias (0 to ±35 V continuously variable) |
| Option 101 | HP-IB (GPIB) Interface |
Power & Physical
| Parameter | Value |
|---|---|
| Line Voltage Requirements | 100 V, 120 V, 220 V (±10%), 240 V (+5%, -10%) |
| Line Frequency Range | 48 Hz to 66 Hz |
| Warm-up Time | 30 minutes |
Display
| Parameter | Value |
|---|---|
| Maximum Display Resolution | 5-1/2 digits |
Monitor Functions
| Parameter | Value |
|---|---|
| Voltage Monitor Accuracy | ±(10% of reading + 1 mV) |
| Current Monitor Accuracy | ±(10% of reading + 10 µA) |
Inputs & Outputs
| Parameter | Value |
|---|---|
| External Trigger Input | TTL level, negative-going edge, ≥ 1 µs pulse width |
Measurement Control
| Parameter | Value |
|---|---|
| Cable Length Compensation Settings | 0 m, 1 m |
Power
| Parameter | Value |
|---|---|
| Maximum Power Consumption | 165 VA (with all options installed) |
Environmental
| Parameter | Value |
|---|---|
| Storage Temperature Range | -40 °C to +75 °C |
| Operating Humidity Range | ≤ 95% RH @ 40 °C |
| Maximum Operating Altitude | 4562 m (15,000 ft) |
DC Bias
| Parameter | Value |
|---|---|
| Option 001 DC Bias Voltage Accuracy | ±(0.5% of setting + 20 mV) |
Connectivity
| Parameter | Value |
|---|---|
| HP-IB Interface Capability Codes | SH1, AH1, T5, L4, SR1, RL1, DC1, DT1, PP0, C0, TE0, LE0 |
Options
| Parameter | Value |
|---|---|
| Option 002 Multi-step Signal Level | 1 mV to 1.00 V rms (1 mV steps from 1 mV to 100 mV, 10 mV steps from 100 mV to 1 V) |
Measurement Monitor
| Parameter | Value |
|---|---|
| Voltage Monitor Range | 1.00 mV to 1.00 V |
| Current Monitor Range | 1.00 µA to 10.00 mA |
Performance
| Parameter | Value |
|---|---|
| Measurement Speed (Short Mode) | 140 ms (at ≥100 kHz) to 190 ms (at 10 kHz) |
| Measurement Speed (Medium Mode) | 160 ms (at ≥100 kHz) to 210 ms (at 10 kHz) |
| Measurement Speed (Long Mode) | 280 ms (at ≥100 kHz) to 370 ms (at 10 kHz) |
| Test Signal Level Accuracy | ±(10% + 10 mV) (at standard 0.1 V to 1.0 V levels) |
Technology
Multi-Frequency LCR Meter
Applications
High-frequency electronic component and material characterization