The Keysight (Agilent) 4288A is a high-speed, high-precision capacitance meter designed specifically for capacitor testing in production environments. Operating at test frequencies of 1 kHz and 1 MHz, it offers reliable and rapid measurements with a basic capacitance accuracy of 0.07% and a test speed as fast as 6.5 ms, making it ideal for high-throughput ceramic capacitor testing.

Specifications

General

ParameterValue
InterfacesGPIB, Handler Interface (Opt. 201/202), Scanner Interface (Opt. 301)
DisplayLiquid Crystal Display (LCD) with backlight
Recommended Calibration Cycle1 year

Physical

ParameterValue
Operating Temperature0 to 55 °C
Dimensions (W×H×D)320 mm x 100 mm x 300 mm
Weight3.0 kg

Measurement Characteristics

ParameterValue
Measurement ParametersCp-D, Cp-Q, Cp-G, Cp-Rp, Cs-D, Cs-Q, Cs-Rs
Test Frequencies1 kHz, 1 MHz
Test Frequency Accuracy±0.01%
Test Signal Levels0.1 V, 0.5 V, 1.0 V rms
Basic Capacitance Accuracy0.07%
Basic Dissipation Factor Accuracy0.0005
Capacitance Measurement Range at 1 kHz100 pF to 20 µF
Capacitance Measurement Range at 1 MHz1 pF to 1000 pF
Measurement Speed (1 MHz, Short)6.5 ms
Measurement Speed (1 MHz, Medium)19 ms
Measurement Speed (1 MHz, Long)53 ms
Measurement Speed (1 kHz, Short)18 ms
Measurement Speed (1 kHz, Medium)31 ms
Measurement Speed (1 kHz, Long)65 ms
Equivalent Circuit ModesSeries, Parallel
Averaging Range1 to 256
Capacitance Display Range0.0001 pF to 99.999 µF
Dissipation Factor Display Range0.00001 to 9.99999
Measurement Terminal Structure4-terminal pair configuration

Trigger and Sweep

ParameterValue
Trigger Source OptionsInternal, Manual, External, GPIB
Trigger Delay Time0 ms to 9.999 s
Trigger Delay Step Size1 ms
Step Delay Time0 ms to 9.999 s
Step Delay Step Size1 ms

Correction and Compensation

ParameterValue
Open CorrectionReduces stray capacitance and conductance
Short CorrectionReduces residual inductance and resistance
Cable Length Compensation Settings0 m, 1 m, 2 m

Comparator and Binning Functions

ParameterValue
Number of Bin sorting channels9 bins for primary parameter
Auxiliary BinYes
Out-of-Bin SortingYes
Comparator LimitsTolerance percentage, Absolute value, Deviation
Beeper ConfigurationOff, Pass, Fail sound patterns

Interfaces and Connectivity

ParameterValue
GPIB Interface TypeIEEE-488
Handler Interface Options36-pin (Opt. 201) / 45-pin (Opt. 202)
Scanner Interface OptionOpt. 301 Multi-channel Compensation

Display and Memory

ParameterValue
Measurement Display Digits6 digits max
Save/Recall Memory10 registers for instrument configuration
Key Lock FunctionYes

Power and Electrical Specifications

ParameterValue
Line Voltage Capability90 V to 132 V AC, 198 V to 264 V AC
Max Power Consumption40 VA

Environmental and Physical Specifications

ParameterValue
Warm-up Time10 minutes
Cabinet Width320 mm
Cabinet Height100 mm
Cabinet Depth300 mm

Measurement Configuration

ParameterValue
External DC Bias Input Range0 V to 40 V
Source Impedance20 Ω nominal (at 1 kHz); 1 Ω or 20 Ω nominal (at 1 MHz, range dependent)

Measurement Functions

ParameterValue
Deviation Measurement ModesDeviation (Δ), Percent Deviation (Δ%)

Inputs & Outputs

ParameterValue
External Trigger Input ConnectorBNC female (rear panel)
External DC Bias Input ConnectorBNC female (rear panel)

Memory & Interface

ParameterValue
Save/Recall Memory Capacity10 instrument setups

Product Options

ParameterValue
Calibration Certificate OptionsOption 1A7 (ISO 17025 compliant), Option A6J (ANSI Z540 compliant)

Technology

Capacitance Meter

Applications

Capacitor testing in production lines, laboratory characterization, and high-speed quality control.