The Keysight (Agilent) 4288A is a high-speed, high-precision capacitance meter designed specifically for capacitor testing in production environments. Operating at test frequencies of 1 kHz and 1 MHz, it offers reliable and rapid measurements with a basic capacitance accuracy of 0.07% and a test speed as fast as 6.5 ms, making it ideal for high-throughput ceramic capacitor testing.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | GPIB, Handler Interface (Opt. 201/202), Scanner Interface (Opt. 301) |
| Display | Liquid Crystal Display (LCD) with backlight |
| Recommended Calibration Cycle | 1 year |
Physical
| Parameter | Value |
|---|---|
| Operating Temperature | 0 to 55 °C |
| Dimensions (W×H×D) | 320 mm x 100 mm x 300 mm |
| Weight | 3.0 kg |
Measurement Characteristics
| Parameter | Value |
|---|---|
| Measurement Parameters | Cp-D, Cp-Q, Cp-G, Cp-Rp, Cs-D, Cs-Q, Cs-Rs |
| Test Frequencies | 1 kHz, 1 MHz |
| Test Frequency Accuracy | ±0.01% |
| Test Signal Levels | 0.1 V, 0.5 V, 1.0 V rms |
| Basic Capacitance Accuracy | 0.07% |
| Basic Dissipation Factor Accuracy | 0.0005 |
| Capacitance Measurement Range at 1 kHz | 100 pF to 20 µF |
| Capacitance Measurement Range at 1 MHz | 1 pF to 1000 pF |
| Measurement Speed (1 MHz, Short) | 6.5 ms |
| Measurement Speed (1 MHz, Medium) | 19 ms |
| Measurement Speed (1 MHz, Long) | 53 ms |
| Measurement Speed (1 kHz, Short) | 18 ms |
| Measurement Speed (1 kHz, Medium) | 31 ms |
| Measurement Speed (1 kHz, Long) | 65 ms |
| Equivalent Circuit Modes | Series, Parallel |
| Averaging Range | 1 to 256 |
| Capacitance Display Range | 0.0001 pF to 99.999 µF |
| Dissipation Factor Display Range | 0.00001 to 9.99999 |
| Measurement Terminal Structure | 4-terminal pair configuration |
Trigger and Sweep
| Parameter | Value |
|---|---|
| Trigger Source Options | Internal, Manual, External, GPIB |
| Trigger Delay Time | 0 ms to 9.999 s |
| Trigger Delay Step Size | 1 ms |
| Step Delay Time | 0 ms to 9.999 s |
| Step Delay Step Size | 1 ms |
Correction and Compensation
| Parameter | Value |
|---|---|
| Open Correction | Reduces stray capacitance and conductance |
| Short Correction | Reduces residual inductance and resistance |
| Cable Length Compensation Settings | 0 m, 1 m, 2 m |
Comparator and Binning Functions
| Parameter | Value |
|---|---|
| Number of Bin sorting channels | 9 bins for primary parameter |
| Auxiliary Bin | Yes |
| Out-of-Bin Sorting | Yes |
| Comparator Limits | Tolerance percentage, Absolute value, Deviation |
| Beeper Configuration | Off, Pass, Fail sound patterns |
Interfaces and Connectivity
| Parameter | Value |
|---|---|
| GPIB Interface Type | IEEE-488 |
| Handler Interface Options | 36-pin (Opt. 201) / 45-pin (Opt. 202) |
| Scanner Interface Option | Opt. 301 Multi-channel Compensation |
Display and Memory
| Parameter | Value |
|---|---|
| Measurement Display Digits | 6 digits max |
| Save/Recall Memory | 10 registers for instrument configuration |
| Key Lock Function | Yes |
Power and Electrical Specifications
| Parameter | Value |
|---|---|
| Line Voltage Capability | 90 V to 132 V AC, 198 V to 264 V AC |
| Max Power Consumption | 40 VA |
Environmental and Physical Specifications
| Parameter | Value |
|---|---|
| Warm-up Time | 10 minutes |
| Cabinet Width | 320 mm |
| Cabinet Height | 100 mm |
| Cabinet Depth | 300 mm |
Measurement Configuration
| Parameter | Value |
|---|---|
| External DC Bias Input Range | 0 V to 40 V |
| Source Impedance | 20 Ω nominal (at 1 kHz); 1 Ω or 20 Ω nominal (at 1 MHz, range dependent) |
Measurement Functions
| Parameter | Value |
|---|---|
| Deviation Measurement Modes | Deviation (Δ), Percent Deviation (Δ%) |
Inputs & Outputs
| Parameter | Value |
|---|---|
| External Trigger Input Connector | BNC female (rear panel) |
| External DC Bias Input Connector | BNC female (rear panel) |
Memory & Interface
| Parameter | Value |
|---|---|
| Save/Recall Memory Capacity | 10 instrument setups |
Product Options
| Parameter | Value |
|---|---|
| Calibration Certificate Options | Option 1A7 (ISO 17025 compliant), Option A6J (ANSI Z540 compliant) |
Technology
Capacitance Meter
Applications
Capacitor testing in production lines, laboratory characterization, and high-speed quality control.