The Keysight (Agilent HP) 4352B VCO/PLL Signal Analyzer is designed for evaluating voltage-controlled oscillators (VCOs) and phase-locked loops (PLLs) in both development and production environments. Operating from 10 MHz to 3 GHz, it functions as a signal analyzer and VCO tester to quickly measure RF power, frequency, tuning sensitivity, phase noise, and transients.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | GPIB, 24-bit parallel digital I/O, Centronics parallel printer port, external monitor output, external trigger, LO IN, external program RUN/CONT |
| Display | 9-inch color CRT |
| Warm-up time | 30 minutes |
| Recommended calibration cycle | 1 year |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 90 V to 132 V / 198 V to 264 V, 47 Hz to 66 Hz, 300 VA max |
| Operating Temperature | 10 to 40 °C |
| Dimensions (W×H×D) | 426 mm × 235 mm × 512 mm |
| Weight | 22 kg |
Receiver & RF Input
| Parameter | Value |
|---|---|
| Receiver frequency range | 10 MHz to 3 GHz |
| Receiver input level range | -10 to +20 dBm |
| Receiver connector type | N-type (female) |
| RF power input level range | -10 to +20 dBm |
| RF power measurement resolution | 0.01 dB |
Phase Noise & Spectrum
| Parameter | Value |
|---|---|
| Offset frequency range | 100 Hz to 10 MHz |
| Maximum spectrum span | 10 MHz |
| Spectrum resolution bandwidth (RBW) | 1 Hz to 3 kHz (in 1, 3 steps) |
FM Deviation
| Parameter | Value |
|---|---|
| FM deviation measurement ranges | 2 kHz, 20 kHz, 200 kHz |
| FM deviation resolution | 4 digits |
DUT DC Power Supply
| Parameter | Value |
|---|---|
| DUT DC supply voltage range | 0 to +15.5 V |
| DUT DC supply maximum current | 50 mA |
| DUT DC supply voltage resolution | 1 mV |
| DUT DC supply voltage accuracy | ±(0.2% + 2 mV) |
| DUT DC supply connector | BNC (female) |
| DC power current measurement range | 0 to 50 mA |
| DUT DC supply voltage setting accuracy | ±(0.2% + 2 mV) |
Internal 1 kHz Signal Source
| Parameter | Value |
|---|---|
| Internal signal source frequency | 1 kHz |
| Internal signal source level range | 0 to 1 Vrms (open load) |
| Internal signal source level resolution | 1 mVrms |
| Internal signal source connector type | BNC (female) |
Measurement & Sweep
| Parameter | Value |
|---|---|
| Sweep measurement points (Analyzer mode) | 2 to 801 points |
| Cable loss compensation | Yes (compensates for RF power loss of connecting cable) |
Display & Storage
| Parameter | Value |
|---|---|
| Built-in storage | 3.5 inch flexible disk drive |
Interfaces
| Parameter | Value |
|---|---|
| Digital I/O port | 24-bit parallel digital I/O |
| External LO input port | LO IN |
| External trigger input | Supported |
| External program input | RUN/CONT |
| External monitor output | Supported |
| Printer compatibility | Centronics interface, HP PCL3 language |
| GPIB interface | Supported |
| Keyboard connector | 6-pin mini-DIN (front panel) |
| Printer port | 25-pin D-sub (Centronics) |
DC Control Voltage Source
| Parameter | Value |
|---|---|
| Tuning voltage range | -15 V to +35 V |
| Tuning voltage resolution | 1 mV |
| Tuning voltage maximum current | 20 mA |
Tuning Voltage Source
| Parameter | Value |
|---|---|
| Tuning voltage setting accuracy | ±(0.05% + 2 mV) |
Frequency Reference
| Parameter | Value |
|---|---|
| High stability frequency reference (Option 1D5) stability | ±1.3 × 10^-7 / year |
| External reference input frequency | 10 MHz (±10 ppm) |
| Internal reference output frequency | 10 MHz |
| Internal reference output level | ≥ 0 dBm (typically +2 dBm) |
Measurement Capabilities
| Parameter | Value |
|---|---|
| Measurement modes | VCO Parameter Measurement (Frequency/Tuning Sensitivity/RF Power/DC Current), Phase Noise, Spectrum Monitor, Frequency Transient |
Storage
| Parameter | Value |
|---|---|
| Floppy disk drive | 3.5-inch, DOS and LIF formats |
Power Requirements
| Parameter | Value |
|---|---|
| AC line voltage | 90 V to 132 V / 198 V to 264 V (automatic selection) |
| AC line frequency | 47 Hz to 66 Hz |
| Power consumption | ≤ 300 VA |
Environmental
| Parameter | Value |
|---|---|
| Operating humidity range | 15% to 95% RH (non-condensing) |
| Storage temperature range | -20 °C to +60 °C |
| Operating altitude | Up to 4,500 m |
Technology
VCO and PLL Signal Analysis
Applications
RF Components Evaluation and Production Testing