The Keysight (Agilent/HP) 4934A Transmission Impairment Measurement Set (TIMS) is a rugged, portable analog circuit tester designed for telephone companies and service providers. Operating over a 20 Hz to 110 kHz bandwidth, it enables comprehensive transmission testing in compliance with the IEEE 743-1984 North American standard. Equipped with WECO 310 connectors and multiple weighting filters, the 4934A measures level/frequency, noise-to-ground, notched noise, SNR, 3-level impulse noise, and Peak-to-Average Ratio (P/AR) for installation and maintenance productivity.

Specifications

General

ParameterValue
InterfacesWECO 310 jacks, Dial/Talk Binding Posts
DisplayDual 4-digit LED displays

Physical

ParameterValue
Operating Temperature0 to 50

Transmitter (Signal Generator) Specifications

ParameterValue
Transmitter Frequency Range20 Hz to 110 kHz
Transmitter Frequency Resolution1 Hz (20 to 9999 Hz), 10 Hz (10.0 to 99.9 kHz), 100 Hz (100.0 to 110.0 kHz)
Transmitter Output Level Range (600 Ω)-40 to +13 dBm
Transmitter Output Level Resolution0.1 dB
Transmitter Output Impedances135 Ω, 600 Ω, 900 Ω

Receiver Specifications

ParameterValue
Receiver Frequency Range20 Hz to 110 kHz
Receiver Level Resolution0.1 dB

Noise and Distortion Measurements

ParameterValue
Noise Weighting FiltersC-message, 3 kHz flat, 15 kHz flat, Program, 50 kbit
Impulse Noise Counters3 independent counters up to 9999 counts
Peak-to-Average Ratio (P/AR) Range0 to 120 P/AR units

Telecom and Signaling Interface Features

ParameterValue
Line Connection Modes2-wire, 4-wire
Dial/Talk Set InterfaceAllows connection of standard test sets via binding posts

Physical & Environmental

ParameterValue
Standards ComplianceIEEE 743-1984 North American standard

Configuration & Options

ParameterValue
Bell Version Impedance Configuration135 Ω, 600 Ω, 900 Ω
CCITT Version (Option 010) Impedance Configuration150 Ω, 600 Ω, 900 Ω

Technology

Analog Telecom Testing

Applications

Transmission Impairment Measurement