The Keysight (Agilent HP) 5087A is a highly reliable RF and frequency distribution amplifier designed to distribute stable frequency reference signals without introducing phase noise or signal degradation. Capable of routing signals from 100 kHz up to 10 MHz, the modular mainframe accommodates up to three input channels and up to twelve output channels. It features excellent channel-to-channel isolation, extremely low additive phase noise, and an automatic AC-to-DC backup power switchover to ensure constant uptime for critical synchronization systems.

Specifications

General

ParameterValue
InterfacesAnalog RF BNC connectors (no digital programming interface)
DisplayFront-panel analog RF level meter with selector switch

Physical

ParameterValue
Power Supply115 / 230 V AC ±10% (48 to 440 Hz), 20 VA max; 22 to 30 V DC, 300 mA max
Operating Temperature0 to 50 °C
Dimensions (W×H×D)425 mm × 88.9 mm × 286 mm
Weight5.4 kg

Input Specifications

ParameterValue
Nominal Input Frequencies100 kHz, 1 MHz, 5 MHz, 10 MHz
Number of InputsUp to 3 (module dependent)
Input Signal Level Range0.25 Vrms to 3.0 Vrms
Input Impedance50 ohms
Maximum Safe Input Level5 V (DC + peak AC)
Input Connector TypeBNC female

Output Specifications

ParameterValue
Number of Standard ChannelsUp to 3 channels
Number of Outputs per Channel4
Total Maximum Outputs12
Output Connector TypeBNC female
Output Impedance50 ohms
Output Signal LevelUp to 3 Vrms (into 50 ohms), 1 Vrms nominal
Output Level Adjustment RangeContinuously adjustable from <0.2 Vrms to >3 Vrms
Harmonic Distortion<-40 dB
Non-Harmonic Spurious Outputs<-80 dB

Isolation & Signal Integrity

ParameterValue
Channel-to-Channel IsolationBetween outputs: >60 dB at 10 MHz, >75 dB at 5 MHz, >90 dB at 1 MHz and 100 kHz; Between channels: >100 dB
Reverse Isolation>90 dB
Phase Noise Additive (1 Hz offset)<-130 dBc/Hz (at 5 MHz)
Phase Noise Additive (10 Hz offset)<-140 dBc/Hz (at 5 MHz)
Phase Noise Additive (100 Hz offset)<-145 dBc/Hz (at 5 MHz)
Phase Noise Additive (1 kHz offset)<-150 dBc/Hz (at 5 MHz)
Phase Noise Additive (10 kHz offset)<-150 dBc/Hz (at 5 MHz)
Phase Stability vs Temperature<0.1 ns/°C (0 to 50°C)
Short-term Stability Contribution (Allan Deviation)<1 x 10^-13 for 1 second averaging time

Modular Configuration & Options

ParameterValue
Mainframe Configuration3 input module slots, 3 output module slots

Monitoring & Control Interfaces

ParameterValue
Front Panel Status IndicatorsPower indicator lamp
Front Panel RF Level MeterAnalog meter with 3-position channel selection switch

Power Specifications

ParameterValue
AC Input Voltage Range115 / 230 V AC ±10%
AC Line Frequency Range48 Hz to 440 Hz
Power Consumption (Maximum)20 VA
DC Input Backup Voltage Range22 V to 30 V DC
DC Power Consumption300 mA
Automatic AC-to-DC SwitchoverYes (seamless switchover to DC backup in the event of AC loss)

Physical and Mechanical

ParameterValue
Form Factor2U Benchtop / Rackmount
Width425 mm
Height88.9 mm
Depth286 mm
Weight (Net)5.4 kg
Weight (Shipping)8.2 kg

Environmental & Compliance

ParameterValue
Operating Temperature Range0°C to 55°C

Phase Stability & Noise

ParameterValue
Phase Stability vs Line Voltage< 0.05 ns for a 10% line voltage change

RF Performance

ParameterValue
Input SWR< 1.15 at 1, 5, and 10 MHz
Output SWR< 1.15 at 1, 5, and 10 MHz
Hum and Noise Sidebands<-80 dBc

Environmental

ParameterValue
Storage Temperature Range-40 °C to +75 °C
Operating AltitudeUp to 4,600 m (15,000 ft)
Non-Operating AltitudeUp to 15,000 m (50,000 ft)

Performance

ParameterValue
Output-to-Output Isolation>60 dB at 5 MHz (between any two outputs in a single channel)

Technology

Analog RF

Applications

RF and Frequency Distribution