The Keysight Agilent 54645A is a classic 2-channel, 100-MHz digital storage oscilloscope designed for mixed-signal troubleshooting. Featuring Agilent's proprietary MegaZoom technology, it offers a deep 1 MB memory per channel and a 200 MSa/s sample rate, allowing engineers to capture long time spans with a high sampling resolution and a highly responsive analog-like display update rate.

Specifications

General

ParameterValue
InterfacesRear-panel expansion slot (supports optional HP-IB, RS-232, or Parallel interface modules)
Display7-inch monochrome raster CRT

Physical

ParameterValue
Power Supply100 to 240 VAC (±10%), 45 to 440 Hz, 100 VA max
Operating Temperature0 °C to +55 °C
Dimensions (W×H×D)322 mm × 172 mm × 317 mm
Weight6.2 kg

Vertical System - Analog Channels

ParameterValue
Analog Bandwidth (-3 dB)100 MHz
Number of Input Channels2
Calculated Rise Time3.5 ns
Input Impedance1 MΩ || ~13 pF
Input CouplingAC, DC, GND
Input Sensitivity Range1 mV/div to 5 V/div
Vertical Resolution8 bits
Maximum Input Voltage400 V (DC + peak AC)
DC Gain Accuracy (2 mV/div to 5 V/div)±2%
DC Gain Accuracy (1 mV/div)±3%
Offset Range (1 mV/div to 100 mV/div)±2 V
Offset Range (101 mV/div to 5 V/div)±40 V

Horizontal System

ParameterValue
Timebase Range2 ns/div to 50 s/div
Timebase Accuracy±0.01%
Horizontal ModesMain, Delayed, Roll, XY
Post-trigger Delay Range1,000,000 divisions or 50 s
Delay Jitter10 ppm
Pre-trigger Delay Range1,000,000 divisions or 5 s

Acquisition System

ParameterValue
Maximum Real-Time Sample Rate200 MSa/s per channel
Maximum Record Length1 MB per channel
Acquisition TechnologyMegaZoom
Glitch Capture CapabilityGlitches as narrow as 5 ns
Peak Detect Minimum Pulse Width5 ns
Maximum Update RateUp to 3,000,000 points/s

Trigger System

ParameterValue
Trigger SourcesChannel 1, Channel 2, External, Line
Trigger ModesAuto, Auto Level, Normal, Single
Standard Trigger TypesEdge, Glitch
Glitch Trigger Width Range8 ns to 8.38 s
External Trigger Input Impedance1 MΩ || ~13 pF
External Trigger Max Input Voltage400 V (DC + peak AC)
Trigger CouplingAC, DC, LF Reject, HF Reject, Noise Reject
Trigger Level Range (Internal)±12 divisions from center of screen
Trigger Holdoff Range200 ns to 13 s
Internal Trigger SensitivityDC to 25 MHz: 0.35 div or 3.5 mV; 25 MHz to 100 MHz: 1.0 div or 10 mV
External Trigger SensitivityDC to 25 MHz: 40 mV; 25 MHz to 100 MHz: 80 mV

Waveform Measurements and Analysis

ParameterValue
Automatic Voltage MeasurementsVp-p, Vmax, Vmin, Vtop, Vbase, Vavg, Vrms
Automatic Time MeasurementsPeriod, Frequency, Rise time, Fall time, +Width, -Width, Duty Cycle
Cursor MeasurementsVoltage (V1, V2, dV) and Time (t1, t2, dt, 1/dt)
Waveform Math OperatorsChannel 1 + Channel 2, Channel 1 - Channel 2

Storage Capabilities

ParameterValue
Setup Storage10 nonvolatile front-panel setups
Trace Memory Storage4 nonvolatile trace memories

Display and User Interface

ParameterValue
Display Graticule8 x 10 divisions
AutoscaleSingle-button automatic setup of active channels

Environmental and Compliance

ParameterValue
Operating AltitudeUp to 4,600 m (15,000 ft)
Non-operating AltitudeUp to 15,240 m (50,000 ft)

Vertical System

ParameterValue
Bandwidth Limit Filter20 MHz
Channel Isolation>= 40 dB at 100 MHz
Common Mode Rejection20 dB at 50 MHz
Dynamic Range±8 div from screen center

Environmental

ParameterValue
Operating Humidity95% RH at 40 °C
Vibration Limit0.38 mm p-p, 5 to 55 Hz, 3 axes, 15 minutes per axis
Shock Limit30 g, 1/2 sine, 11 ms duration, 3 shocks per axis

Power

ParameterValue
Power ConsumptionMaximum 220 VA

Triggering

ParameterValue
External Trigger Level Range±18 V

I/O & Expandability

ParameterValue
Supported Interface ModulesHP 54650A (GPIB), HP 54651A (RS-232), HP 54652B (RS-232/Parallel), HP 54657A (GPIB with Measurement/FFT), HP 54659B (RS-232/Parallel with Measurement/FFT)

Compliance

ParameterValue
Safety StandardsCertified to CSA C22.2 No. 1010.1, Complies with EN 61010-1 / IEC 1010-1
EMC StandardsComplies with CISPR 11 Class A, EN 50082-1

Maintenance

ParameterValue
Recommended Calibration Cycle1 year

Technology

Digital Storage Oscilloscope (DSO)

Applications

Electronic Design and Troubleshooting, Mixed-Signal Analysis, Education