The HP 81533B is an optical head interface module designed for use with the Hewlett-Packard (later Agilent / Keysight) 8153A Lightwave Multimeter mainframe. It serves as the interface between the mainframe and various HP 8152x series high-performance optical heads, enabling high-precision optical power measurements over a broad spectrum of wavelengths and power levels.

Specifications

General

ParameterValue
Interfaces1x Optical head front-panel input connector, mainframe backplane interface (rear)
Display0.001 dB/dBm, 0.01 pW to 10 pW (via HP 8153A mainframe)

Physical

ParameterValue
Power SupplyPowered by HP 8153A mainframe backplane
Operating Temperature0 °C to 55 °C
Dimensions (W×H×D)32 mm × 75 mm × 335 mm
Weight0.5 kg

System Architecture

ParameterValue
Mainframe CompatibilityHP 8153A Lightwave Multimeter
Compatible Optical HeadsHP 81520A, HP 81521B, HP 81524A, HP 81525A
Form FactorSingle-slot plug-in module for HP 8153A mainframe

System Performance

ParameterValue
Warmup Time20 minutes
Applicable Fiber Type9/125 µm to 100/140 µm, NA ≤ 0.3
Display Resolution (Logarithmic)0.001 dB/dBm
Display Resolution (Linear)0.01 pW to 10 pW

Performance with HP 81520A

ParameterValue
Sensor Element (with HP 81520A)Si, 5 mm diameter
Wavelength Range (with HP 81520A)450 to 1020 nm
Power Measurement Range (with HP 81520A)+10 to -100 dBm
Peak-to-Peak Noise (with HP 81520A)<50 fW (average time 1 s)
Power Uncertainty / Accuracy (with HP 81520A)±2.2%

Performance with HP 81521B

ParameterValue
Sensor Element (with HP 81521B)Ge, 5 mm diameter
Wavelength Range (with HP 81521B)900 to 1700 nm
Power Measurement Range (with HP 81521B)+3 to -80 dBm
Peak-to-Peak Noise (with HP 81521B)<5 pW (average time 1 s)
Power Uncertainty / Accuracy (with HP 81521B)±2.2%

Performance with HP 81524A

ParameterValue
Sensor Element (with HP 81524A)InGaAs, 5 mm diameter
Wavelength Range (with HP 81524A)800 to 1650 nm
Power Measurement Range (with HP 81524A)+3 to -90 dBm
Peak-to-Peak Noise (with HP 81524A)<0.5 pW (average time 1 s)
Power Uncertainty / Accuracy (with HP 81524A)±2.2%

Performance with HP 81525A

ParameterValue
Sensor Element (with HP 81525A)InGaAs, 5 mm diameter
Wavelength Range (with HP 81525A)800 to 1650 nm
Power Measurement Range (with HP 81525A)+27 to -70 dBm (1250 to 1650 nm), +23 to -70 dBm (800 to 1250 nm)
Peak-to-Peak Noise (with HP 81525A)<50 pW (average time 1 s)
Power Uncertainty / Accuracy (with HP 81525A)±3.0%

Configuration

ParameterValue
Number of Channels1

Analog Output

ParameterValue
Analog Output Voltage Range0 V to 2 V (into open circuit, linear proportional to power)
Analog Output Impedance600 Ω (typical)
Analog Output ConnectorBNC

Inputs & Outputs

ParameterValue
Optical Head Connector Interface15-pin D-Sub

Environmental

ParameterValue
Storage Temperature-40 °C to +75 °C
Operating Humidity95% R.H. (from 0 °C to 40 °C, non-condensing)

Maintenance

ParameterValue
Calibration Interval1 year

Technology

Fiber Optic Test & Measurement

Applications

Optical Power Measurement