The Keysight/Agilent/HP 83622B is a high-performance synthesized sweeper that offers a frequency range of 2.0 to 20 GHz. Designed for applications requiring the precision of a synthesized source and the speed of a sweep oscillator, it features indirect synthesis for low phase noise, extensive sweep modes, and versatile modulation capabilities including pulse, amplitude, and frequency modulation.

Specifications

General

ParameterValue
InterfacesGPIB (IEEE-488)
DisplayMonochrome CRT

Physical

ParameterValue
Power Supply90 to 132 VAC / 198 to 264 VAC, 48 to 440 Hz, 400 VA maximum
Operating Temperature0 to 55 °C
Dimensions (W×H×D)425 mm × 178 mm × 648 mm
Weight27 kg

Frequency Specifications

ParameterValue
Frequency Range2.0 to 20 GHz
Standard Frequency Resolution1 kHz
Frequency Resolution (Option 008)1 Hz
Synthesis TypeIndirect synthesis

RF Output Specifications

ParameterValue
Maximum Leveled Power+13 dBm
Minimum Leveled Power (Option 001)-110 dBm

Spectral Purity

ParameterValue
Harmonics (< 20 GHz)<-50 dBc
SSB Phase Noise (10 kHz offset)<-80 dBc/Hz at 10 GHz

Modulation Capabilities

ParameterValue
Modulation CapabilitiesPulse, amplitude, and frequency modulation

Sweep Modes & Triggering

ParameterValue
Sweep ModesCW, manual, step, list, ramp
Sweep Control FunctionsStart/stop, center/span, marker (M1-M2), alternate sweep
Sweep Trigger SourcesAuto, external, single, or GPIB
CW Mode AccuracySame as time base
Manual Mode AccuracySame as time base
Step Sweep Number of Points2 to 801
Step Sweep Dwell Time Range1 ms to 10 s
Step Sweep AccuracySame as time base
Step Sweep Minimum Step SizeSame as frequency resolution
List Sweep Number of Points1 to 801
List Sweep Dwell Time Range1 ms to 10 s
List Sweep AccuracySame as time base
List Sweep Minimum Step SizeSame as frequency resolution
Ramp Sweep Time Range10 ms to 100 s
Ramp Sweep Maximum Rate300 MHz/ms
Ramp Sweep Accuracy (sweep time ≥100 ms and ≤5 s)Lesser of 1% of sweep width or n × 1 MHz + 0.1% of sweep width (for sweep widths >n × 10 MHz)

Performance

ParameterValue
CW Switching Time (within frequency band)< 15 ms
Step or List Mode Switching Time (within frequency band)< 5 ms
Non-harmonic Spurious< -60 dBc (at offsets > 3 kHz from carrier)

RF Output

ParameterValue
RF Output ConnectorPrecision 3.5 mm female
Output Impedance50 Ω nominal

Level

ParameterValue
Level Resolution0.1 dB

Frequency Reference

ParameterValue
Internal Reference Frequency10 MHz
External Reference Input1, 2, 5, or 10 MHz (±5 ppm)
External Reference Input Level-3 to +20 dBm

Modulation

ParameterValue
External AM 3 dB BandwidthDC to 100 kHz
External FM Rate (Locked)100 kHz to 8 MHz
External FM Rate (Unlocked)100 Hz to 1 MHz
Pulse Modulation Rise/Fall Time< 10 ns
Pulse Modulation On/Off Ratio> 80 dB
Pulse Modulation Minimum Pulse Width< 50 ns (unleveled), < 1 µs (leveled)
External Pulse Input ThresholdTTL compatible
Internal Modulation Generator WaveformsSine, square, triangle, ramp, noise (Option 002 dependent)
Internal Pulse Width Range25 ns to 419 ms (Option 002 dependent)

System & Control

ParameterValue
GPIB Command LanguagesSCPI, HP 8340B/8341B emulation

Output

ParameterValue
Output Flatness±0.6 dB
Output SWR< 2.0
Power Level Accuracy±0.9 dB
Power Sweep Range> 15 dB (standard) / > 125 dB (with Option 001 step attenuator)

Reference

ParameterValue
Internal Reference Aging Rate< 1 × 10^-9 / day, < 2.5 × 10^-7 / year (after 72-hour warm-up)

Technology

Indirect synthesis

Applications

RF and microwave testing, local oscillator emulation, sweep frequency measurements