The Keysight Agilent HP 8719D is a high-performance microwave vector network analyzer designed for fast, accurate, and comprehensive S-parameter characterization of active and passive components. Operating over a frequency range of 50 MHz to 13.5 GHz, the 8719D features an integrated synthesized source, solid-state switching S-parameter test set, and vector receiver. An upgraded processor ensures measurement speed and data transfers are up to seven times faster than previous generations.
Specifications
Physical
| Parameter | Value |
|---|---|
| Weight | 25 kg |
Source Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 50 MHz to 13.5 GHz |
| Frequency Resolution | 1 Hz |
Receiver Specifications
| Parameter | Value |
|---|---|
| Receiver Frequency Range | 50 MHz to 13.5 GHz |
Test Port Characteristics
| Parameter | Value |
|---|---|
| Test Port Connector Type | 3.5 mm male |
| Test Port Impedance | 50 Ω |
Measurement Capabilities & Formats
| Parameter | Value |
|---|---|
| Measurement Parameters | S11, S21, S12, S22 |
| Display Formats | Log/Linear Magnitude, Phase, Group Delay, Smith Chart, Polar, SWR, Real, Imaginary |
| Sweep Types | Linear Frequency, Log Frequency, List Frequency, Power Sweep |
Display & User Interface
| Parameter | Value |
|---|---|
| Limit Lines Capability | Upper/lower limits, flat, sloped, and single-point limits |
Rear Panel Interfaces & Connectivity
| Parameter | Value |
|---|---|
| External Trigger Input | TTL-compatible |
| VGA Video Output | 15-pin D-sub |
Storage & File Management
| Parameter | Value |
|---|---|
| Internal Storage Type | 3.5-inch floppy disk drive |
| Internal Disk Formats | LIF, MS-DOS |
Environmental & Reliability
| Parameter | Value |
|---|---|
| Calibration Cycle | 1 year |
Factory Options & Configurations
| Parameter | Value |
|---|---|
| Option 010 | Time-Domain Analysis |
| Option 1D5 | High-Stability Frequency Reference |
| Option 012 | Direct Access Receiver Configuration |
Display Reference Level
| Parameter | Value |
|---|---|
| Magnitude Reference Level Range | ±500 dB |
| Magnitude Reference Level Resolution | 0.001 dB |
| Phase Reference Level Resolution | 0.01° |
Instrument Options
| Parameter | Value |
|---|---|
| Option 085 | High-power analyzer (adds attenuators and mechanical switch, supports up to 20 W input) |
| Option 089 | Frequency offset mode (for mixer measurements) |
| Option 400 | Four-sampler receiver (adds reference sampler for TRL/LRM calibration) |
Rear Panel Connections
| Parameter | Value |
|---|---|
| Test Port Bias Inputs | Two rear-panel BNC female connectors, 40 V, 500 mA maximum |
| Limit Test Output | BNC female, TTL output (high = pass, low = fail) |
| Keyboard Connector | Mini-DIN connector for external keyboard |
Environmental
| Parameter | Value |
|---|---|
| Operating Humidity | 5% to 95% relative humidity (non-condensing) at +40 °C |
Standards Compliance
| Parameter | Value |
|---|---|
| EMC Compliance | Complies with CISPR 11 Group 1 Class A, EN 50082-1 |
Technology
Vector Network Analyzer
Applications
Microwave component testing, S-parameter measurement, time-domain analysis, group delay characterization