The HP Keysight 8753B is a high-performance vector network analyzer designed for laboratory and production-level reflection and transmission measurements of RF components. It features an integrated synthesized RF source and a dual-channel, three-input receiver capable of measuring magnitude, phase, and group delay. With advanced digital signal processing and micro-processor controls, the 8753B provides exceptional measurement accuracy and user convenience.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | HP-IB (GPIB) |
Source Characteristics
| Parameter | Value |
|---|---|
| Frequency Range | 300 kHz to 3 GHz |
| Sweep Types | Linear, Logarithmic, Frequency List, Power Sweep |
Receiver Characteristics
| Parameter | Value |
|---|---|
| Number of Inputs | 3 (R, A, B) |
| Input Impedance | 50 Ω (nominal) |
Measurement Functions & Display
| Parameter | Value |
|---|---|
| Measured Parameters | Magnitude, Phase, Group Delay (Reflection and Transmission) |
| Display Channels | 2 independent channels |
| Display Formats | Log/Linear Magnitude, Phase, Group Delay, Polar, Smith Chart, SWR |
| Number of Measurement Points | Up to 1601 points per sweep |
| Trace Math | Supported (Data/Memory, Data-Memory, etc.) |
| Signal Processing Features | Trace math, data averaging, trace smoothing, electrical delay |
Calibration & Error Correction
| Parameter | Value |
|---|---|
| Calibration Types | Response, Response/Isolation, 1-Port, 2-Port |
| Error Correction Algorithms | Full 1-port, Full 2-port, Interpolated, Response, Response/Isolation |
| Interpolated Error Correction | Supported |
System Capabilities & Connectivity
| Parameter | Value |
|---|---|
| Remote Programming Interface | HP-IB (GPIB) |
| Direct Output to Peripherals | Supported (print or plot directly without external computer) |
| External Storage Control | Supports compatible external disc drives |
| Service Diagnostics | Built-in troubleshooting and diagnostic procedures |
| Impedance Environments | 50 ohm and 75 ohm compatibility (with compatible test sets and accessories) |
Options
| Parameter | Value |
|---|---|
| Option 002 | Swept harmonic measurements of RF amplifiers |
| Option 006 | Extends receiver frequency range to 6 GHz |
| Option 010 | Frequency domain to time domain transformation |
| Option 908 | Rack mount kit without handles |
| Option 913 | Rack mount kit with handles |
Receiver Performance
| Parameter | Value |
|---|---|
| Receiver Dynamic Range | 100 dB (300 kHz to 3 GHz, 10 Hz IF BW) |
Frequency Reference
| Parameter | Value |
|---|---|
| Internal Reference Frequency | 10 MHz |
Rear Panel Connections
| Parameter | Value |
|---|---|
| Auxiliary Input | Rear-panel BNC (female), ±10 V analog input |
Technology
Vector Network Analyzer
Applications
RF and Microwave Component Characterization