The Agilent 8753ES is a high-performance vector network analyzer designed for complete characterization of RF components, offering precise S-parameter measurements from 30 kHz up to 6 GHz. It features a built-in S-parameter test set and advanced calibration capabilities including full two-port, adapter-removal, and TRL/LRM methods.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | GPIB (IEEE-488), VGA output, External Reference Input/Output (BNC), Trigger Input/Output (BNC) |
| Display | 8.4-inch Color LCD (640 x 480 pixels) |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 90-264 VAC, 47-66 Hz, 350 VA max |
| Operating Temperature | 0 to 55 °C |
| Dimensions (W×H×D) | 425 mm × 222 mm × 550 mm |
| Weight | 23 kg |
Frequency Characteristics
| Parameter | Value |
|---|---|
| Frequency Range | 30 kHz to 3 GHz / 6 GHz (frequency-option dependent) |
| Frequency Resolution | 1 Hz |
| Frequency Accuracy | ±5 ppm |
| Frequency Stability | ±0.1 ppm/°C |
| Frequency Range (by option) | 30 kHz to 3 GHz (standard); 30 kHz to 6 / 10 / 11 / 13.5 / 20 GHz (option dependent) |
Output Power Specifications (Source)
| Parameter | Value |
|---|---|
| Output Power Range | -5 to +10 dBm (standard, typical) |
| Power Level Resolution | 0.01 dB |
| Power Level Accuracy | ±1.0 dB (typical) |
| Harmonics | <-25 dBc (typical) |
| Non-Harmonic Spurious | <-30 dBc (typical) |
| Output Impedance | 50 Ohm / 75 Ohm (configuration dependent) |
| Power Sweep Range | 15 dB (typical) |
Receiver Characteristics
| Parameter | Value |
|---|---|
| Input Power Range (Damage Level) | +20 dBm max |
| Noise Floor | <-100 dBm (at 10 Hz IFBW, 30 kHz - 3 GHz) |
| 1 dB Compression Point | +5 dBm (typical) |
System Performance (Calibrated)
| Parameter | Value |
|---|---|
| Dynamic Range | Up to 100 dB (at 10 Hz IFBW) |
| Directivity | >40 dB (calibrated, typical) |
| Source Match | >30 dB (calibrated, typical) |
| Load Match | >30 dB (calibrated, typical) |
| Transmission Tracking | ±0.2 dB (typical) |
| Reflection Tracking | ±0.3 dB (typical) |
| Trace Noise (Magnitude) | <0.01 dB RMS (at 10 Hz IFBW) |
| Trace Noise (Phase) | <0.1 degree RMS (at 10 Hz IFBW) |
| Stability (Magnitude) | <0.02 dB/°C (typical) |
| Stability (Phase) | <0.2 °/°C (typical) |
| Port Impedance | 50 Ohm / 75 Ohm (option dependent) |
Measurement Capabilities
| Parameter | Value |
|---|---|
| Measurement Parameters | S11, S21, S12, S22 (S-parameters) |
| Number of Ports | 2 |
| Sweep Types | Linear Frequency, Log Frequency, Power, CW (Zero Span), Time Domain (optional) |
| Number of Measurement Points | 3 to 1601 (configurable) |
| IF Bandwidth Range | 10 Hz to 280 kHz |
| Sweep Speed | ~100 ms (201 points, 10 kHz IFBW) |
| Calibration Methods Supported | Full 2-port, 1-port, Response, Enhanced Response, Adapter-removal, TRL/LRM |
| Averaging Types | Point, Sweep |
| Time Domain Analysis | Available with Option 010 |
Display Features
| Parameter | Value |
|---|---|
| Display Type | Color LCD |
| Display Size | 8.4-inch (diagonal) |
| Resolution | 640 x 480 pixels (VGA) |
| Number of Traces | Up to 4 |
| Number of Channels | 1 |
| Marker Functions | Standard (readout, delta, bandwidth, search) |
Interfaces and Connectivity
| Parameter | Value |
|---|---|
| GPIB (IEEE-488) | Yes |
| VGA Output | Yes |
| External Reference Input | 10 MHz (BNC) |
| Reference Output | 10 MHz (BNC) |
| Trigger Input | Yes (BNC) |
| Trigger Output | Yes (BNC) |
General Specifications
| Parameter | Value |
|---|---|
| Storage Temperature Range | -40 to 70 °C |
| Humidity Range | 5% to 95% RH (non-condensing) |
| Altitude | Up to 4600 m |
| Power Requirements (Voltage) | 90 to 264 VAC |
| Power Requirements (Frequency) | 47 to 66 Hz |
| Power Consumption | 350 VA max |
| Regulatory Compliance (CE) | Yes |
| Safety Compliance | IEC 1010-1 / EN 61010-1 |
Software and Automation
| Parameter | Value |
|---|---|
| Programming Language Support | SCPI |
Options and Accessories
| Parameter | Value |
|---|---|
| Available Options | Option 006 (6 GHz Frequency Extension), Option 075 (75 Ohm Test Port Impedance), Option 010 (Time Domain Analysis), Option 002 (Harmonics Measurement), Option ECal (Electronic Calibration Module) |
| Rack Mount Kit | Available |
Connectivity
| Parameter | Value |
|---|---|
| Test Port Connector Type | N-type, female |
| External Keyboard Interface | PS/2 |
| External Mouse Interface | PS/2 |
| Printer Interface | Parallel (Centronics compatible) |
| Auxiliary I/O Interface | 15-pin D-sub |
| External Reference Input (Nominal) | 10 MHz, 0 dBm, 50 Ohm BNC |
| Reference Output (Nominal) | 10 MHz, 0 dBm, 50 Ohm BNC |
| Serial Port | RS-232, 9-pin D-sub |
| Parallel Port | 25-pin D-sub |
Performance
| Parameter | Value |
|---|---|
| Number of Measurement Receivers | 3 (R, A, B) |
Measurement Display
| Parameter | Value |
|---|---|
| Trace Display Formats | Log Magnitude, Linear Magnitude, Phase, Group Delay, Smith Chart (Impedance/Admittance), Polar, VSWR, Real, Imaginary |
Storage
| Parameter | Value |
|---|---|
| Internal Storage | Hard drive, 3.5-inch floppy drive |
Software
| Parameter | Value |
|---|---|
| System Firmware | Embedded proprietary operating system |
Measurement Characteristics
| Parameter | Value |
|---|---|
| Measurement Speed (per point) | 100 µs/point (typ.) |
| IF Bandwidth Resolution | 1 Hz |
Source Characteristics
| Parameter | Value |
|---|---|
| Source Attenuator Range | 0 to 70 dB |
| Source Attenuator Step Size | 10 dB |
| Phase Noise (1 GHz carrier, 1 kHz offset) | -90 dBc/Hz (typ.) |
System Characteristics
| Parameter | Value |
|---|---|
| Internal Storage Type | 3.5-inch Floppy Disk Drive |
Power
| Parameter | Value |
|---|---|
| Power Consumption (Max VA) | 500 VA |
Environmental
| Parameter | Value |
|---|---|
| Non-Operating Altitude | 0 to 15,300 m |
Display
| Parameter | Value |
|---|---|
| Number of Markers | 9 independent markers |
| Limit Lines | 2 independent limit lines |
| Trace Math Functions | A-B, B-A, R/A, B/A |
Technology
Vector Network Analysis
Applications
RF component characterization