The Keysight Technologies (formerly Agilent) DSO5054A is a 500 MHz, 4-channel digital storage oscilloscope from the 5000 Series. Powered by proprietary third-generation MegaZoom III technology, it delivers high-performance deep memory (1 Mpts), a fast real-time sample rate of 4 GSa/s, and a responsive display system offering up to 100,000 waveforms per second update rate, avoiding the typical trade-offs found in traditional bench scopes.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | USB (2 host, 1 device), LAN (100 MBit), GPIB, LXI Class C |
| Display | 6.3-inch color LCD, VGA (640 x 480) resolution with 256 levels of intensity grading |
| Built-in Help Languages | English, French, German, Italian, Japanese, Korean, Portuguese, Russian, Simplified Chinese, Spanish, Traditional Chinese |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 100 - 240 V AC ±10% (auto-ranging), 47 - 440 Hz, up to 120 W maximum |
| Operating Temperature | 0 °C to +55 °C |
| Dimensions (W×H×D) | 354 mm × 188 mm × 174 mm |
| Weight | 4.1 |
Key Performance Specifications
| Parameter | Value |
|---|---|
| Analog Bandwidth | 500 MHz |
| Number of Analog Channels | 4 |
| Maximum Real-Time Sample Rate | 4 GSa/s (2 GSa/s with all channels active) |
| Maximum Memory Depth | 8 Mpts |
| Waveform Update Rate | Up to 100,000 waveforms per second |
Vertical System (Analog Channels)
| Parameter | Value |
|---|---|
| Analog Bandwidth (-3 dB) | 500 MHz |
| Calculated Rise Time (10% to 90%) | 700 ps |
| Input Coupling | AC, DC, GND |
| Input Impedance | 1 MΩ ± 1% (13 pF) or 50 Ω ± 1% selectable |
| Input Sensitivity Range (1 MΩ) | 2 mV/div to 5 V/div |
| Input Sensitivity Range (50 Ω) | 2 mV/div to 1 V/div |
| Vertical Resolution | 8 bits |
| Maximum Input Voltage (1 MΩ) | CAT I 300 Vrms, 400 Vpk |
| Maximum Input Voltage (50 Ω) | 5 Vrms |
| DC Vertical Accuracy | ±2% of full scale |
| Hardware Bandwidth Limiters | 20 MHz selectable |
Horizontal System (Acquisition)
| Parameter | Value |
|---|---|
| Timebase Range | 500 ps/div to 50 s/div |
| Timebase Accuracy | ±15 ppm |
| Channel-to-Channel Deskew Range | ±100 ns |
Trigger System
| Parameter | Value |
|---|---|
| Trigger Sources | Ch 1, Ch 2, Ch 3, Ch 4, Line, External |
| Trigger Modes | Auto, Normal, Single |
| Trigger Coupling | AC, DC, LF reject, HF reject, noise reject |
| Trigger Level Range (Internal) | ±6 divisions from center screen |
| Trigger Level Range (External) | ±8 V |
| Trigger Holdoff Range | 60 ns to 10 s |
| Edge Triggering | Rising, falling, alternating |
| Pulse Width Triggering | Positive or negative pulse width (<, >, =), 15 ns to 10 s |
| Video/TV Triggering | NTSC, PAL, SECAM, 480p, 576p, 720p, 1080i, 1080p |
| Serial Triggering Options | I2C, SPI, CAN, LIN, UART/RS-232 (with optional licenses) |
| Trigger Sensitivity (Internal) | < 10 MHz: 0.5 div or 5 mV; 10 MHz to max bandwidth: 1 div or 10 mV |
| Trigger Sensitivity (External) | DC to 100 MHz: 100 mV; 100 MHz to max bandwidth: 200 mV |
Signal Acquisition Modes
| Parameter | Value |
|---|---|
| Real-Time Acquisition Mode | Yes |
| Peak Detect Mode | 250 ps (at 4 GSa/s), 500 ps (at 2 GSa/s) |
| Averaging Mode | Selectable from 2 to 65,536 |
| High-Resolution Mode | Up to 12 bits of resolution (at timebases ≥10 μs/div) |
| Roll Mode | Yes (500 ms/div to 50 s/div) |
Waveform Measurements and Analysis
| Parameter | Value |
|---|---|
| Automatic Voltage Measurements | Peak-to-peak, Maximum, Minimum, Amplitude, Top, Base, Overshoot, Preshoot, Average, RMS |
| Automatic Time Measurements | Period, Frequency, Rise time, Fall time, +Width, -Width, Duty cycle |
| Automatic Frequency/Phase Measurements | Frequency, Phase, Delay |
| Cursor Measurements | Amplitude (Y), Time (X) |
| Waveform Math Operators | Addition, Subtraction, Multiplication, FFT |
| FFT Windows | Hanning, Flat Top, Rectangular |
Display and User Interface
| Parameter | Value |
|---|---|
| Display Type | 6.3-inch color LCD |
| Display Resolution | QVGA (320 x 240) |
| Display Intensity Grading | 256 levels |
| Waveform Display Formats | YT, XY |
| Graticule Types | 8 x 10 divisions |
Connectivity and I/O Interfaces
| Parameter | Value |
|---|---|
| USB Host Ports | 1 host port (front panel) |
| USB Device Port | 1 device port (rear panel) |
| LAN Interface | 100 MBit LAN |
| LXI Compliance | LXI Class C |
| GPIB Interface | Optional |
| External Trigger Input | Yes |
| VGA Video Output | 15-pin D-sub (XGA display out) |
Power Requirements
| Parameter | Value |
|---|---|
| AC Input Voltage Range | 100 V to 240 V AC |
| Power Consumption | 120 W maximum |
Physical Characteristics
| Parameter | Value |
|---|---|
| Height | 188 mm |
| Width | 354 mm |
| Depth | 174 mm |
Environmental Specifications
| Parameter | Value |
|---|---|
| Non-Operating Temperature | -40 °C to +70 °C |
| Operating Humidity | 95% RH at 40 °C |
| Operating Altitude | Up to 4,600 m (15,000 ft) |
| Non-Operating Altitude | Up to 15,300 m (50,000 ft) |
Vertical System
| Parameter | Value |
|---|---|
| Channel-to-Channel Isolation | > 40 dB from DC to 500 MHz |
| Input Capacitance (1 MΩ) | 11 pF |
| Dynamic Range | ±8 divisions from screen center |
| Probe Interface | AutoProbe |
| Offset Range (1 M̤) | ±2 V (2 mV to 200 mV/div), ±50 V (>200 mV to 5 V/div), ±100 V (>5 V to 10 V/div) |
| Offset Range (50 ̤) | ±2 V (2 mV to 200 mV/div), ±50 V (>200 mV to 5 V/div) |
Measurements
| Parameter | Value |
|---|---|
| Built-in Hardware Frequency Counter | 5-digit resolution (max frequency equal to oscilloscope analog bandwidth) |
Environmental
| Parameter | Value |
|---|---|
| Acoustic Noise | 30 dBA (typical) at operator position |
Accessories
| Parameter | Value |
|---|---|
| Standard Included Probes | One 10073D 10:1 passive probe per channel |
Acquisition System
| Parameter | Value |
|---|---|
| Segmented Memory | Standard, max 1000 segments |
| Segmented Memory Re-arm Time | < 8 μs |
| High-Resolution Mode Vertical Resolution | Up to 12 bits of resolution (at ≥ 10 μs/div) |
Measurements & Analysis
| Parameter | Value |
|---|---|
| Measurement Statistics | Displays min, max, mean, standard deviation, and count for up to 4 simultaneous measurements |
| Mask Testing | Optional (Option LMT), up to 100,000 tests/second pass/fail rate |
| Built-in Hardware Counter Resolution | 5 digits (up to 500 MHz) |
Storage & Connectivity
| Parameter | Value |
|---|---|
| Internal Storage (Setups/Waveforms) | 10 internal setups and waveforms |
| Supported File Formats (USB) | BMP, PNG, CSV, ASCII XY, Binary, Setup (.set) |
Environmental & Standards
| Parameter | Value |
|---|---|
| Electromagnetic Compatibility (EMC) | IEC 61326-1, EN 61326-1, CISPR 11/EN 55011 Group 1 Class A, ICES-001, AS/NZS CISPR 11 |
| Safety Standards | UL 61010-1:2004, CAN/CSA-C22.2 No. 61010-1:2004, EN 61010-1:2001 |
| Vibration Standard | MIL-PRF-28800F Class 3 random vibration |
| Shock Standard | MIL-PRF-28800F Class 3 (functional, 30 g, half-sine, 11 ms duration) |
Technology
Digital Storage Oscilloscope (DSO)
Applications