The Keysight (formerly Agilent) DSO6054L is a 500 MHz, 4-channel low-profile digital storage oscilloscope designed to provide high-performance measurements in a compact 1U-high rackmount form factor. Optimized for automated test and manufacturing environments, it offers up to 4 GSa/s real-time sample rates, 8 Mpts of standard acquisition memory, and complete LXI Class C compliance. The unit is headless (without a built-in screen), designed for remote configuration via its graphical Web browser interface or for local connection to an external monitor via its standard XGA video output port. It is 100% software-compatible with the portable InfiniiVision 6000A Series oscilloscopes.

Specifications

General

ParameterValue
InterfacesUSB (Host and Device), LAN, GPIB, External Trigger Input, XGA Video Output
DisplayNone (headless, external monitor support via XGA port or remote graphical Web interface)
CoolingForced air (side-to-side venting)

Physical

ParameterValue
Power Supply100 - 240 V AC, 50/60 Hz, automatic selection
Operating Temperature0 °C to +50 °C
Dimensions (W×H×D)437 mm × 43.6 mm × 269 mm
Weight4.1 kg
Rack Height1U (43.6 mm)

Vertical System - Analog Channels

ParameterValue
Analog Bandwidth (-3 dB)500 MHz
Number of Input Channels4
Input Impedance1 MΩ ± 1% (13 pF), 50 Ω ± 1.5%
Input CouplingAC, DC
Vertical Resolution8-bit
Input Sensitivity Range2 mV/div to 5 V/div (1 MΩ), 2 mV/div to 1 V/div (50 Ω)
Maximum Input VoltageCAT I 300 Vrms, 400 Vpk (1 MΩ); 5 Vrms (50 Ω)
Hardware Bandwidth Limits20 MHz (selectable)
DC Gain Accuracy±2.0% of full scale

Horizontal System

ParameterValue
Timebase Range500 ps/div to 50 s/div
Timebase Accuracy±15 ppm
Channel-to-Channel Deskew Range±100 ns

Acquisition System

ParameterValue
Maximum Real-Time Sample Rate4 GSa/s (interleaved), 2 GSa/s (per channel)
Maximum Record Length (Memory Depth)8 Mpts (interleaved), 4 Mpts (per channel)
Waveform Capture RateUp to 100,000 waveforms/sec
Acquisition ModesNormal, Average, Peak Detect, High Resolution

Trigger System

ParameterValue
Trigger SourcesChannel 1, 2, 3, 4, External, Line
Trigger ModesAuto, Normal, Single
Trigger CouplingAC, DC, LF Reject, HF Reject, Noise Reject
Trigger Holdoff Range60 ns to 10 s
Standard Trigger TypesEdge, Pulse Width, Pattern, TV/Video, Duration, Sequence
Advanced / Protocol Triggering OptionsI²C, SPI, CAN, LIN, RS-232/UART, I²S, MIL-STD 1553 (with options)
Trigger Output High Level≥ 2.5 V into open circuit, ≥ 1.0 V into 50 Ω
Trigger Output Low Level≤ 0.5 V
Trigger Output Source Impedance~ 50 Ω

Waveform Measurements and Analysis

ParameterValue
Automatic MeasurementsVoltage (peak-to-peak, max, min, amplitude, top, base, overshot, undershoot, average, RMS), Time (frequency, period, rise time, fall time, positive width, negative width, duty cycle)
Waveform Math OperatorsAddition, Subtraction, Multiplication, FFT
FFT Window TypesHanning, Flat Top, Rectangular, Blackman-Harris

Display and User Interface

ParameterValue
Waveform Display FormatsYT, XY
Remote User InterfaceBuilt-in graphical Web browser control (Java-enabled)

Connectivity and Interfaces

ParameterValue
USB Host Ports2 x USB 2.0 Host (1 front, 1 rear)
USB Device Port1 x USB 2.0 Device (rear panel)
LAN Interface (LXI)10/100Base-T (LXI Class C compliant)
GPIB InterfaceStandard IEEE-488
Video Output PortXGA (15-pin D-sub)
External Trigger InputYes (rear panel)

Power Specifications

ParameterValue
Power Consumption120 VA maximum

Environmental and Compliance

ParameterValue
Storage Temperature Range-40 °C to +70 °C
Operating Humidity95% RH at 40 °C
Operating AltitudeUp to 4,600 m (15,000 ft)
Electromagnetic Compatibility (EMC)IEC 61326-1, EN 61326-1
Safety CertificationsUL61010-1, CSA C22.2 No. 61010-1, IEC 61010-1

Physical Characteristics

ParameterValue
Form Factor1U Rackmount

Vertical System

ParameterValue
Channel-to-Channel Isolation> 40 dB (100:1) from DC to 500 MHz
Calculated Rise Time700 ps

Frequency Reference

ParameterValue
10 MHz Reference Input Amplitude180 mVrms to 1.5 Vrms
10 MHz Reference Input Impedance50 Ω
10 MHz Reference Input Frequency Accuracy10 MHz ± 5 ppm
10 MHz Reference Output Amplitude≥ 360 mVrms into 50 Ω

Standards and Connectivity

ParameterValue
LXI ComplianceLXI Class C
Remote Programming CommandsSCPI, IEEE 488.2

Environmental

ParameterValue
Operating Vibration0.3 g(rms), 5 Hz to 500 Hz
Non-operating Vibration2.41 g(rms), 5 Hz to 500 Hz
Non-operating Shock30 g, half-sine, 11 ms duration
Acoustic Noise38 dBA at front panel

Technology

Digital Storage Oscilloscope (DSO)

Applications

Automated Test, Manufacturing Test, System Integration, Design Verification