The Keysight (formerly Agilent) InfiniiVision DSO7104A is a 1 GHz, 4-channel digital storage oscilloscope featuring a large 12.1-inch XGA display, always-on MegaZoom III deep memory, and an industry-leading uncompromised update rate of up to 100,000 waveforms per second. Designed for capturing subtle signal details and infrequent events, it offers complete connectivity including USB, LAN, and LXI compliance in a compact physical footprint.

Specifications

General

ParameterValue
Interfaces3 x USB 2.0 host ports, 1 x USB 2.0 device port, LAN (10/100Base-T, LXI Class C), VGA out; GPIB (optional)
Display12.1-inch diagonal XGA color TFT LCD, 1024 x 768 pixels, 256 intensity levels
Standard Warranty3 years

Physical

ParameterValue
Power Supply100 - 240 V AC, 50/60 Hz / 100 - 120 V AC, 400 Hz, automatic selection, 120 W maximum
Operating Temperature0 to +50 °C
Dimensions (W×H×D)381 mm × 324 mm × 165 mm
Weight5.9 kg

Vertical System

ParameterValue
Number of Analog Channels4
Analog Bandwidth (-3 dB)1 GHz
Calculated Rise Time (10% to 90%)350 ps
Input Impedance1 MΩ ± 1% (14 pF) or 50 Ω ± 1.5% (selectable)
Input CouplingAC, DC
Vertical Resolution8 bits
Vertical Sensitivity Range (1 MΩ)2 mV/div to 5 V/div
Vertical Sensitivity Range (50 Ω)2 mV/div to 1 V/div
Maximum Input Voltage (1 MΩ)300 Vrms CAT I, 150 Vrms CAT II
Maximum Input Voltage (50 Ω)5 Vrms
DC Vertical Gain Accuracy±2.0% of full scale
Hardware Bandwidth Limit Filters20 MHz
Channel-to-Channel Isolation40 dB (DC to 1 GHz)
Offset Range (1 MΩ)±5 V (2 mV to 200 mV/div), ±100 V (206 mV to 5 V/div)
Offset Range (50 Ω)±5 V (2 mV to 200 mV/div), ±50 V (206 mV to 1 V/div)
Dynamic Range±8 divisions from screen center
Common Mode Rejection Ratio20 dB at 50 MHz (with 50 Ω inputs)

Horizontal System

ParameterValue
Timebase Range500 ps/div to 50 s/div
Timebase Accuracy±15 ppm
Horizontal ModesMain, Zoom, Roll, XY
Channel-to-Channel Deskew±100 ns
Timebase Delay Range (Pre-trigger)Greater of 1 screen width or 250 μs (fast timebases) or 10,000 divisions (slow timebases)
Timebase Delay Range (Post-trigger)1 s to 10,000 s (depending on sweep speed)

Acquisition System

ParameterValue
Maximum Real-time Sample Rate4 GSa/s (half-channel interleaved), 2 GSa/s (all channels)
Maximum Memory Depth8 Mpts (standard, MegaZoom III)
Acquisition ModesNormal, Peak Detect, Averaging, High Resolution, Segmented
Peak Detection Resolution250 ps (half-channel), 500 ps (all channels)
Maximum Waveform Update Rate100,000 waveforms/s
Segmented Memory CapacityUp to 2,000 segments (configuration dependent)

Trigger System

ParameterValue
Trigger SourcesChannel 1, Channel 2, Channel 3, Channel 4, Line, External
Trigger ModesAuto, Normal, Single
Trigger CouplingAC, DC, LF Reject, HF Reject, Noise Reject
Trigger Holdoff Range60 ns to 10 s
Edge TriggeringRising, falling, alternating, or either edge on any source
Pulse Width TriggeringPulse width <, >, =, or ≠ a specific time (2 ns to 10 s)
Video/TV TriggeringNTSC, PAL, SECAM, HDTV (480i, 480p, 576i, 576p, 720p, 1080i, 1080p)
Serial Protocol Triggering OptionsI²C, SPI, CAN, LIN, FlexRay, RS-232/UART
External Trigger Input Range±8 V (1 MΩ), ±5 V (50 Ω)
External Trigger Input Impedance1 MΩ ± 1% || 14 pF or 50 Ω (selectable)
Trigger Jitter15 ps rms (typical)
External Trigger BandwidthDC to 1 GHz
Trigger Sensitivity (Internal)< 10 mV/div: greater of 1 div or 5 mV; ≥ 10 mV/div: 0.6 div
External Trigger SensitivityDC to 1 GHz: 250 mV (high sensitivity range) or 1.0 V (normal range)

Waveform Measurements & Analysis

ParameterValue
Automatic Voltage MeasurementsPeak-to-peak, Maximum, Minimum, Amplitude, Top, Base, Overshoot, Preshoot, Average, RMS
Automatic Time MeasurementsPeriod, Frequency, Rise Time, Fall Time, +Width, -Width, Duty Cycle, Delay, Phase
Waveform Math FunctionsAddition, Subtraction, Multiplication, FFT
FFT Window FunctionsHanning, Flat Top, Rectangular, Blackman-Harris
Cursor MeasurementsManual, Track, and Auto-measure cursors
Hardware-accelerated Mask TestingSupported (option LMT or N5455A)

Display & User Interface

ParameterValue
Display TypeColor TFT LCD
Display Size12.1 inches (307 mm) diagonal
Display Resolution1024 × 768 pixels (XGA)
Intensity Graduation Levels256 levels

Connectivity & Interfaces

ParameterValue
USB Host Ports3 x USB 2.0 (one front, two rear)
USB Device Port1 x USB 2.0 high-speed device port (rear)
LAN Interface (LXI)10/100Base-T, LXI Class C compliant
VGA Video Output15-pin D-sub female connector (rear)
Trigger Out / Aux OutputBNC connector (rear), 0 to 5 V into 1 MΩ, 0 to 2.5 V into 50 Ω
Probe Calibrator Output (Probe Comp)Front panel terminals, ~1.2 kHz, ~2.5 Vpp

Power & Environmental

ParameterValue
AC Input Voltage Range100 V to 240 V AC
Line Frequency Range50/60 Hz (100-240 V), 400 Hz (100-120 V)
Power Consumption120 W maximum
Storage Temperature Range-40 °C to +70 °C
Operating Humidity95% RH at 40 °C (non-condensing)
Operating AltitudeUp to 4,600 m (15,000 ft)
Electromagnetic Compatibility (EMC)IEC 61326-1, EN 61326-1, CISPR 11 Class A
Safety StandardsUL61010-1, CSA22.2 No. 61010-1, EN61010-1

Physical Characteristics

ParameterValue
Height324 mm
Width381 mm
Depth165 mm
Weight (Net)5.9 kg
Kensington Lock SlotStandard rear panel slot

Input Channels

ParameterValue
Input Capacitance14 pF (at 1 MΩ)

Frequency Counter

ParameterValue
Built-in Frequency Counter5-digit, max frequency equivalent to oscilloscope bandwidth

User Interface & Help

ParameterValue
Operating SystemWindows CE
Built-in Help Languages11 languages (English, French, German, Italian, Japanese, Korean, Portuguese, Russian, Simplified Chinese, Spanish, Traditional Chinese)

Connectivity & I/O

ParameterValue
10 MHz Reference InputBNC, 0.5 Vpp to 5 Vpp, 10 MHz
10 MHz Reference OutputBNC, 1.5 Vpp into 50 Ω, 10 MHz
Probe Interface TypeAgilent AutoProbe interface

Accessories

ParameterValue
Standard Included ProbesFour 10073D 10:1 passive probes (500 MHz)

Connectivity

ParameterValue
Web ServerBuilt-in web browser remote control
GPIB InterfaceStandard

Data Storage

ParameterValue
Internal Non-volatile Memory10 setups and 10 waveforms

Software & Control

ParameterValue
Supported DriversIVI-COM, LabVIEW, MATLAB

Technology

Digital Storage Oscilloscope (DSO)

Applications

Electronic design, debug, and characterization