The Keysight (Agilent/HP) E1401B is a high-performance, 13-slot, C-size VXI modular instrument mainframe. It is engineered to meet the demands of high-density instrumentation systems by providing ultra-reliable power distribution, high peak and dynamic currents, and advanced cooling technology. Designed for rapid serviceability with a Mean Time To Repair (MTTR) of under 5 minutes for fans and power supplies, it is a mainstay in automated test environments requiring high performance and low downtime.

Specifications

General

ParameterValue
Interfaces25-pin D-sub diagnostic/monitoring connector on rear panel
DisplayFront panel status LEDs (+5V, -5.2V, +12V, -12V, +24V, -24V, -2V, Fan, Temp, Access)

Physical

ParameterValue
Power Supply90 - 263 VAC (47 - 66 Hz) / 103 - 140 VAC (360 - 440 Hz), 1500 VA max, auto-ranging
Operating Temperature0°C to 55°C
Dimensions (W×H×D)483 mm × 352 mm × 631 mm (with rack flanges)
Weight20.0
Rack Height8U
Shipping Weight26.8 kg

System Architecture & Slot Configuration

ParameterValue
Mainframe FormatVXI C-size
Total Number of Slots13
Slot Size CompatibilityC-size
VXIbus Specification ComplianceRevision 1.4
Slot Spacing30.48 mm (1.2 inches)
Interrupt/Grant Line JumperingSolid-state automatic daisy-chain jumper connections for VMEbus BG/IACK lines

Power Supply Input Specifications

ParameterValue
AC Input Voltage Range90 - 263 VAC
AC Input Frequency Range47 - 66 Hz (90 - 263 VAC) / 360 - 440 Hz (103 - 140 VAC)
Maximum Input Power1500 VA
Power Supply ServiceabilityRear-removable modular design with MTTR < 5 minutes

Power Supply Output Specifications

ParameterValue
Total Usable Output Power900 W (0°C to 55°C)
Peak Current +5V Rail90 A
Peak Current -5.2V Rail60 A
Peak Current +12V Rail15 A
Peak Current +24V Rail15 A
Peak Current -2V Rail30 A
Dynamic Current +5V Rail9.0 A
Dynamic Current -5.2V Rail6.0 A
Dynamic Current +12V Rail1.5 A
Dynamic Current +24V Rail3.0 A
Dynamic Current -2V Rail3.0 A

Cooling & Thermal Management

ParameterValue
Airflow DirectionRear panel intake, exhausting out the sides and top
Cooling Capacity per Slot100 W (for a 15°C temperature rise)
Fan Speed Control ModeAutomatic temperature-sensing or full-speed switch
Number of Cooling Fans3
Fan ServiceabilityRear panel access, replaceable in < 5 minutes

Backplane Signal & Timing Performance

ParameterValue
Trigger LinesSupports VXI standard TTLTRG and ECLTRG lines

System Monitoring & Diagnostics

ParameterValue
Diagnostic Monitor ConnectorRear-panel 25-pin D-sub
Voltage MonitoringAnalog voltage level outputs on rear diagnostic connector
Status IndicatorsFront-panel LEDs (+5V, -5.2V, +12V, -12V, +24V, -24V, -2V, Fan, Temp)
Over-Temperature WarningLED indicator and rear-panel diagnostic signal output
Fan Fail SensorLED indicator and rear-panel diagnostic signal output

Physical Specifications

ParameterValue
Form Factor / Height8U EIA Rack Units
Chassis Width (excluding ears)426 mm
Chassis Height352 mm
Chassis Depth (overall)631 mm
Chassis Depth (chassis body only)580 mm
Weight (without modules)20 kg

Environmental Conditions

ParameterValue
Storage Temperature Range-40°C to +75°C
Operating Humidity RangeUp to 95% RH (non-condensing) at 40°C
Operating AltitudeUp to 4,600 m (15,000 ft)
Storage AltitudeUp to 15,000 m (50,000 ft)

Compliance & Certifications

ParameterValue
VXIbus ComplianceVXIbus Revision 1.4, VXIplug&play compliant
Safety StandardsUL 1244, CSA C22.2 No. 231, EN 61010-1
EMC StandardsEN 55011 Class A, CISPR 11 Class A, FCC Part 15 Class A

Accessories & Options

ParameterValue
Backplane Connector Shield Kit Part NumberE1400-80920

Power Specifications

ParameterValue
AC Input Maximum Current15.0 A (100-120 VAC) / 8.0 A (220-240 VAC)

Cooling Specifications

ParameterValue
Maximum Airflow (High Speed)90 L/s
Maximum Airflow (Low Speed)50 L/s

Acoustic Specifications

ParameterValue
Acoustic Noise (High Speed)52.5 dBA
Acoustic Noise (Low Speed)43.5 dBA

Environmental Specifications

ParameterValue
Operating Vibration0.22 g rms, 5 to 500 Hz
Survival Vibration2.09 g rms, 5 to 500 Hz
Operating Shock3 g, 11 ms, half-sine
Survival Shock30 g, 11 ms, half-sine

Backplane Specifications

ParameterValue
CLK10 Frequency10 MHz

Diagnostics & Monitoring

ParameterValue
Diagnostic Connector Type25-pin female D-sub

Power Supply

ParameterValue
Power Factor CorrectionActive PFC, 0.99 typical (115 VAC)

Cooling

ParameterValue
Air FilterRemovable and washable

Technology

VXIbus

Applications

Modular instrumentation and automated testing systems