The Keysight (formerly Agilent/HP) E4416A is a high-performance single-channel EPM-P series peak and average power meter. Designed for complex modulation formats, it provides a 20 MSa/s continuous sampling rate for reliable single-shot and time-gated measurements. When paired with E9320 series peak and average power sensors, it delivers up to 5 MHz of video bandwidth and extensive statistical analysis capabilities, making it ideal for characterizing broadband wireless and radar signals.

Specifications

General

ParameterValue
InterfacesGPIB (IEEE-488), RS-232/422
DisplayHigh-resolution LCD with backlighting

Physical

ParameterValue
Power Supply100 to 240 VAC, 50/60/400 Hz, 50 VA max
Operating Temperature0 to 55
Dimensions (W×H×D)212.6 × 88.5 × 348.3
Weight4.0

Measurement Capabilities

ParameterValue
Number of Channels1
Frequency Range9 kHz to 110 GHz (sensor dependent)
Power Range-70 to +44 dBm (sensor dependent)
Measurement ModesPeak, average, peak-to-average ratio, time-gated, free run
Supported Sensor SeriesE9320, E9300, E-series CW, 8480 series
Number of Time Gates4
E9320 Series Dynamic Range70 dB maximum (normal mode); 85 dB maximum (average only mode)
E9300 Series Dynamic Range80 dB maximum
E-series CW Dynamic Range90 dB maximum
8480 Series Dynamic Range50 dB maximum

Accuracy and Calibration

ParameterValue
1 mW Reference Power Level1.000 mW (0.0 dBm)
1 mW Reference Frequency50 MHz
1 mW Reference ConnectorType-N (female)

Video and Timing Characteristics

ParameterValue
Sample Rate20 MSa/s
Maximum Video Bandwidth5 MHz (with E932x sensors)

Display Characteristics

ParameterValue
Display Resolution (Logarithmic)Selectable 1.0, 0.1, 0.01, 0.001 dB
Display Resolution (Linear)1 to 4 significant digits
Offset Range±100 dB in 0.001 dB increments

Rear Panel Inputs and Outputs

ParameterValue
Trigger Input Connector TypeBNC (female)
Trigger Output Connector TypeBNC (female)
Analog Recorder Output ConnectorBNC (female)

Physical Specifications

ParameterValue
Rackmount Unit (RU) Size2U (Half-rack width)

Performance

ParameterValue
Measurement SpeedUp to 1,000 readings/s (fast mode over GPIB)
Instrumentation Accuracy (Logarithmic)± 0.02 dB (Average mode)
Instrumentation Accuracy (Linear)± 0.5% (Average mode)

Measurement & Control

ParameterValue
Averaging Settings1 to 1024

Triggering

ParameterValue
Internal TriggeringYes

Power & Environmental

ParameterValue
Power Consumption50 VA max

Inputs & Outputs

ParameterValue
Rear Panel Connectivity (Option 002)Rear-panel sensor input and rear-panel reference
Rear Panel Connectivity (Option 003)Rear-panel sensor input and reference calibrator
Analog Recorder Output Voltage0 to 1 Vdc (into ≥ 1 kΩ)
Analog Recorder Output Impedance1 kΩ

Software & Control

ParameterValue
Programming CompatibilitySCPI, HP 437B, Agilent EPM series
Supported StandardsIEEE 488.2

Environmental

ParameterValue
Storage Temperature-20 °C to +70 °C
Maximum Operating Altitude3,000 m (9,840 ft)
Maximum Storage Altitude15,240 m (50,000 ft)

Technology

RF & Microwave Power Measurement

Applications

Wireless communications test, radar pulse measurement, component test