The Keysight / Agilent E5062A is a general-purpose RF vector network analyzer in the ENA-L series, operating from 300 kHz to 3 GHz. Designed to provide reliable basic S-parameter and transmission/reflection measurements, it offers a choice of 50 Ω or 75 Ω test port impedance configurations to suit various standard and CATV component testing needs. Delivering up to 120 dB of dynamic range and low 0.005 dB rms trace noise, the E5062A pairs robust measurement performance with built-in Visual Basic for Applications (VBA) programming and a large 10.4-inch color LCD.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | LAN (10/100Base-T), USB (Host and Device), GPIB (IEEE 488), Parallel, VGA Video Out |
| Display | 10.4-inch color TFT LCD |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 90 to 132 V AC / 198 to 264 V AC, 47 to 63 Hz, 350 VA max |
| Operating Temperature | 5 to 40 |
| Dimensions (W×H×D) | 426 × 222 × 286 mm |
| Weight | 13.5 kg |
System Performance
| Parameter | Value |
|---|---|
| Frequency Range | 300 kHz to 3 GHz |
| Standard Impedance | 50 Ω or 75 Ω (option dependent) |
| Dynamic Range | 120 dB (typical) |
| Trace Noise | 0.005 dB rms (typical, at 3 kHz IFBW) |
Test Port Output
| Parameter | Value |
|---|---|
| Frequency Resolution | 1 Hz |
Test Port Input
| Parameter | Value |
|---|---|
| Test Port Connectors (50 Ω) | Type-N (female) |
| Test Port Connectors (75 Ω) | Type-N (female, 75 Ω) |
Sweep Characteristics
| Parameter | Value |
|---|---|
| Sweep Types | Linear frequency, Log frequency, Segment sweep, Power sweep |
| Number of Points | 2 to 1601 points (per channel) |
Measurement Capabilities
| Parameter | Value |
|---|---|
| IF Bandwidth Range | 10 Hz to 30 kHz |
| Independent Channels | Up to 4 channels |
| Traces per Channel | Up to 4 traces |
| Automation & Scripting | Built-in Visual Basic for Applications (VBA) |
| Supported Calibration Types | Response, 1-Port, 2-Port (requires S-parameter options 250/275), Electronic Calibration (ECal) |
Options & Configurations
| Parameter | Value |
|---|---|
| Test Set Configuration | Transmission/Reflection (T/R) or Full 2-Port S-Parameter (option dependent) |
Inputs & Outputs
| Parameter | Value |
|---|---|
| Maximum Input Level | +20 dBm, ±30 VDC |
| External Reference Input | 10 MHz, BNC (female) |
| External Trigger Input | TTL / CMOS compatible, BNC (female) |
| Video Output | 15-pin mini D-Sub (VGA) |
Frequency
| Parameter | Value |
|---|---|
| Frequency Accuracy | ±5 ppm (standard); ±1 ppm (with Option 1E5) |
Performance
| Parameter | Value |
|---|---|
| Measurement Parameters | S11, S21 (T/R test set options); S11, S21, S12, S22 (S-parameter test set options) |
Source
| Parameter | Value |
|---|---|
| Output Power Resolution | 0.05 dB |
Power
| Parameter | Value |
|---|---|
| Power Consumption | 350 VA (maximum) |
Environmental
| Parameter | Value |
|---|---|
| Storage Temperature | -10 °C to +60 °C |
| Operating Humidity | 20% to 80% RH (non-condensing) |
Signal Source
| Parameter | Value |
|---|---|
| Output Power Range | 0 to +10 dBm (Options 150/175); -45 to +10 dBm (Options 250/275) |
Features & Options
| Parameter | Value |
|---|---|
| Time Domain Analysis | Available via Option 010 |
| Fault Location & SRL Analysis | Available via Option 100 |
Software & Automation
| Parameter | Value |
|---|---|
| Built-in Programming | Visual Basic for Applications (VBA) |
Measurement Ports
| Parameter | Value |
|---|---|
| Test Port Damage Level | +20 dBm, ±30 VDC |
Technology
RF Vector Network Analysis
Applications
General-purpose RF component testing, filter tuning, amplifier testing, CATV component measurements