The Keysight (formerly Agilent) E5071B is an ENA Series RF Vector Network Analyzer designed to deliver fast and accurate multi-port measurements for RF components. Covering a frequency range of 300 kHz to 8.5 GHz, the E5071B features integrated 2-, 3-, and 4-port configurations, extensive fixture simulation capabilities, and a built-in VBA environment for automated testing.

Specifications

General

ParameterValue
InterfacesGPIB, LAN (10/100 Base-T), USB, VGA, Parallel
Display10.4-inch color LCD touch screen
Mass StorageBuilt-in Hard Disk Drive (HDD) and 3.5-inch Floppy Disk Drive (FDD)

Physical

ParameterValue
Power Supply90-132 V / 198-264 V, 47-63 Hz, 350 VA max
Operating Temperature5 to 40 °C

General Characteristics

ParameterValue
Instrument TypeRF Vector Network Analyzer
Number of Test Ports2, 3, or 4 ports (integrated, configuration dependent)
System Impedance50 Ω
Supported Connector TypesType-N (female)

Frequency Characteristics

ParameterValue
Frequency Range300 kHz to 8.5 GHz

Test Port Input (Receiver) Characteristics

ParameterValue
Trace Noise (Magnitude)0.001 dB rms

Dynamic Range and System Performance

ParameterValue
System Dynamic Range125 dB at test port (typical)
Measurement Speed (Per Point)9.6 µs/point
IF Bandwidth Settings10 Hz to 100 kHz

Measurement Capabilities

ParameterValue
Frequency-Offset ModeSupported (for frequency translated devices)

Calibration and Error Correction

ParameterValue
ECal SupportYes (USB)

Data Processing and Analysis

ParameterValue
Fixture SimulatorFixture embedding/de-embedding and port characteristic impedance conversion
Programming / AutomationBuilt-in Visual Basic for Applications (VBA)

Options and Configurations

ParameterValue
Companion SoftwareMeasurement Wizard Assistant software

Frequency

ParameterValue
Frequency Resolution1 Hz

Test Port Output

ParameterValue
Output Power Range-50 to +10 dBm
Output Power Resolution0.05 dB

Measurement

ParameterValue
Data Points per Trace2 to 20,001
Number of ChannelsUp to 16 independent channels
Number of TracesUp to 16 traces per channel

Sweep

ParameterValue
Sweep TypesLinear frequency, log frequency, segment sweep, power sweep
Trigger SourcesInternal, External, Manual, Bus

Display & Analysis

ParameterValue
Data FormatsLog magnitude, linear magnitude, phase, group delay, SWR, polar, Smith chart, real, imaginary

Configuration

ParameterValue
Hardware Port Options2-port, 3-port, or 4-port (configuration dependent)

Analysis & Features

ParameterValue
Time Domain AnalysisSupported (requires Option 010)

Programming & Control

ParameterValue
Built-in Macro LanguageVisual Basic for Applications (VBA)

Inputs & Outputs

ParameterValue
External Reference Input Frequency10 MHz
Internal Reference Output Frequency10 MHz

Technology

RF Vector Network Analysis

Applications

RF Component Testing