The Keysight (formerly Agilent/HP) E8408A is a high-performance, 4-slot, C-size VXI mainframe designed for portable, benchtop, or small-scale automated test applications. Combining a highly compact half-rack footprint with 324 W of usable power and robust peak currents on all major VXI voltage rails, the E8408A ensures full compatibility with the VXIbus Revision 1.4 standard while maintaining efficient, quiet, and reliable operation.

Specifications

General

ParameterValue
InterfacesNone (determined by Slot 0 controller card)
DisplayNone (status LEDs only)

Physical

ParameterValue
Power Supply90 to 264 VAC, 47 to 66 Hz (and 360 to 440 Hz at 115 VAC)
Operating Temperature0 to 55 °C
Dimensions (W×H×D)213 mm × 222 mm × 561 mm
Weight11.3 kg

System Architecture & Capacity

ParameterValue
Number of Module Slots4
Compatible Module SizeVXI C-size
VXIbus Compliance VersionRevision 1.4

Power Specifications

ParameterValue
Maximum Usable Module Power324 W (at 55 °C)
Maximum Mains Input Power500 VA
+5V Rail Peak Current30 A
+12V Rail Peak Current4 A
+24V Rail Peak Current4 A
-5.2V Rail Peak Current15 A
-2V Rail Peak Current5 A
+5V Rail Dynamic Current4.5 A
+12V Rail Dynamic Current1.0 A
+24V Rail Dynamic Current1.5 A
-5.2V Rail Dynamic Current3.0 A
-2V Rail Dynamic Current1.0 A

Physical Characteristics

ParameterValue
Form Factor5U portable / benchtop (half-rack width)
Cooling Fan Speed ModesHigh / Variable switchable on rear panel

User Interface & Operation

ParameterValue
Diagnostic InterfaceRear-panel analog power supply monitoring connector

Environmental & Compliance

ParameterValue
Storage Temperature Range-40 °C to +75 °C
Operating Humidity RangeUp to 95% R.H. (non-condensing)
Maximum Operating Altitude4600 m
Maximum Storage Altitude15000 m

Acoustics

ParameterValue
Acoustic Noise (Low Fan Speed)30 dBA (bystander position at 1m)
Acoustic Noise (High Fan Speed)42 dBA (bystander position at 1m)

Backplane Specifications

ParameterValue
Automatic Daisy-chain JumperingYes (for IACK and BG signals)

VXI Backplane

ParameterValue
System Clock (CLK10)10 MHz

Compliance

ParameterValue
Safety ComplianceIEC 61010-1, EN 61010-1, UL 3111-1, CSA C22.2 No. 1010.1
EMC ComplianceEN 55011 (Group 1, Class A), EN 50082-1

Technology

VXI

Applications