The Keysight Technologies (formerly Agilent) InfiniiVision MSO6012A is a high-performance 100 MHz Mixed Signal Oscilloscope featuring 2 analog channels and 16 digital channels. Built with MegaZoom III technology, it delivers a deep 8 Mpts standard memory, an ultra-fast update rate of up to 100,000 waveforms/second, and a high-definition 6.3-inch XGA display with 256 intensity levels. These features make it highly effective for debugging complex analog, digital, and serial bus designs.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | USB 2.0 host (2 ports), USB 2.0 device (1 port) standard; LAN (10/100Base-T), GPIB, XGA Video Output optional |
| Display | 6.3-inch (160 mm) diagonal color flat-panel TFT-LCD, 320 × 240 pixels (QVGA) with 256 levels of intensity |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 100-240 VAC, 50/60 Hz; 100-120 VAC at 400 Hz; Auto-ranging; 120 W maximum |
| Operating Temperature | 0 to +55 °C |
| Dimensions (W×H×D) | 354 mm × 188 mm × 174 mm |
| Weight | 4.9 |
Analog Vertical System
| Parameter | Value |
|---|---|
| Analog Input Channels | 2 |
| Analog Bandwidth (-3 dB) | 100 MHz |
| Calculated Rise Time (10% to 90%) | 3.5 ns |
| Input Coupling | AC, DC |
| Input Impedance | 1 MΩ ± 1% || ~14 pF, or 50 Ω ± 1.5% |
| Input Sensitivity Range | 2 mV/div to 5 V/div (1 MΩ), 2 mV/div to 1 V/div (50 Ω) |
| Vertical Resolution | 8 bits |
| Max Input Voltage (1 MOhm) | CAT I 400 V (DC + peak AC), CAT II 300 V (DC + peak AC) |
| Max Input Voltage (50 Ohm) | 5 Vrms |
| DC Gain Accuracy | ±2.0% of full scale |
| Offset Range | 1 MΩ: ±5 V (<10 mV/div), ±25 V (10 mV/div to 198 mV/div), ±100 V (200 mV/div to 1.98 V/div), ±400 V (2 to 5 V/div); 50 Ω: ±5 V (<10 mV/div), ±25 V (10 to 198 mV/div), ±100 V (200 mV to 1 V/div) |
Digital Vertical System
| Parameter | Value |
|---|---|
| Digital Channels | 16 |
| Threshold Grouping | Pod 1 (D7 - D0), Pod 2 (D15 - D8) |
| Threshold Selections | TTL, CMOS, ECL, user-defined |
| Threshold Voltage Range | ±8.0 V in 10 mV steps |
| Threshold Accuracy | ±(100 mV + 3% of threshold setting) |
| Input Impedance (Digital Probe) | 100 kΩ ± 2% || ~8 pF (with flying-lead probe) |
| Minimum Voltage Swing | 500 mVpp |
| Maximum Toggle Rate | 250 MHz |
Horizontal System
| Parameter | Value |
|---|---|
| Maximum Real-time Sample Rate (Analog) | 2 GSa/s (interleaved), 1 GSa/s (per channel) |
| Maximum Sample Rate (Digital) | 1 GSa/s |
| Maximum Record Length (Analog Channels) | 8 Mpts (interleaved), 4 Mpts (per channel) |
| Maximum Record Length (Digital Channels) | 8 Mpts (interleaved), 4 Mpts (per channel) |
| Time Base Range | 5 ns/div to 50 s/div |
| Time Base Accuracy | ±15 ppm (0.0015%) |
| Channel-to-Channel Deskew Range | ±100 ns |
| Timebase Modes | Main, Zoom, Roll, XY |
| XY Phase Difference | ±1° (from DC to 100 kHz) |
Trigger System
| Parameter | Value |
|---|---|
| Trigger Modes | Normal, Auto, Single |
| Trigger Coupling | AC, DC, LF Reject, HF Reject, Noise Reject |
| Trigger Holdoff Range | 60 ns to 10 s |
| Edge Triggering | Rising, falling, alternating, or either edge on any channel |
| Pulse Width Triggering | Positive or negative pulse from 15 ns to 10 s |
| Runt Triggering | Not supported |
| Setup and Hold Triggering | Trigger on setup/hold violations |
| Pattern Triggering | Trigger on logical state combination across any analog/digital channel |
Acquisition Modes
| Parameter | Value |
|---|---|
| Sample Mode | Successive samples are registered |
| Peak Detect Mode | Captures high-frequency glitches down to 2 ns |
| Averaging Mode | Selectable from 2 to 65536 averages |
| High Resolution Mode | Real-time boxcar filtering reduces random noise and yields up to 12 bits of resolution |
| Segmented Memory Mode | Supported, partition acquisition memory into up to 1,000 segments |
Waveform Analysis & Measurements
| Parameter | Value |
|---|---|
| Automatic Measurements | Voltage: Peak-to-peak, Max, Min, Amplitude, Top, Base, Overshoot, Preshoot, Average, RMS. Time: Frequency, Period, Width, Duty Cycle, Rise, Fall, Phase, Delay |
| Math Functions | Add, Subtract, Multiply, FFT |
| FFT Window Types | Hanning, Flat Top, Rectangular |
Display & User Interface
| Parameter | Value |
|---|---|
| Waveform Update Rate | 100,000 waveforms/second |
Environmental & Compliance
| Parameter | Value |
|---|---|
| Operating Humidity Range | 95% relative humidity at 40 °C (non-condensing) |
| Operating Altitude | Up to 4,600 m (15,000 ft) |
| Non-Operating Altitude | Up to 15,300 m (50,000 ft) |
External Trigger Input
| Parameter | Value |
|---|---|
| External Trigger Max Input Voltage | 400 V (DC + peak AC) CAT I / 300 Vrms CAT II (1 MΩ), 5 Vrms (50 Ω) |
| External Trigger Coupling | DC, AC, LF Reject, HF Reject |
Trigger Sensitivity
| Parameter | Value |
|---|---|
| Internal Trigger Sensitivity | Greater of 1 div or 5 mV (< 10 mV/div), 0.6 div (≥ 10 mV/div) |
| External Trigger Sensitivity | 40 mV (DC to 100 MHz) |
Environmental
| Parameter | Value |
|---|---|
| Storage Temperature Range | -40 °C to +70 °C |
| Operating Vibration | 0.21 g rms (5 Hz to 500 Hz) |
| Non-Operating Vibration | 2.09 g rms (5 Hz to 500 Hz) |
| Operating Shock | 30 g (half-sine, 11 ms duration) |
| Non-Operating Shock | 50 g (half-sine, 11 ms duration) |
Electrical
| Parameter | Value |
|---|---|
| Maximum Power Consumption | 120 W |
Probe Compensation
| Parameter | Value |
|---|---|
| Probe Compensation Output Amplitude | approximately 2.5 Vpp |
| Probe Compensation Output Frequency | approximately 1.2 kHz |
Hardware Frequency Counter
| Parameter | Value |
|---|---|
| Frequency Counter Resolution | 5 digits |
| Frequency Counter Max Frequency | 100 MHz |
Compliance
| Parameter | Value |
|---|---|
| Safety Standards Compliance | UL61010-1, CSA C22.2 No. 61010-1, IEC 61010-1 |
| EMC Standards Compliance | IEC 61326-1, EN 61326-1, CISPR 11/EN 55011 Group 1 Class A |
Analog Input
| Parameter | Value |
|---|---|
| Channel-to-Channel Isolation | ≥ 40 dB (DC to 100 MHz) |
| Bandwidth Limit Filter | 20 MHz (selectable) |
Triggering
| Parameter | Value |
|---|---|
| Trigger Jitter | < 15 ps RMS (typical) |
| Video Triggering Formats | NTSC, PAL, SECAM, HDTV (480i, 480p, 576i, 720p, 1080i, 1080p) |
Digital Channels
| Parameter | Value |
|---|---|
| Minimum Glitch Detection Width | 2 ns |
Accessories
| Parameter | Value |
|---|---|
| Included Probes (Analog) | 2 × 10074C 10:1 passive probes (150 MHz) |
| Included Probes (Digital) | 1 × 54620-68701 16-channel digital probe kit |
Connectivity
| Parameter | Value |
|---|---|
| Trigger Out Output | 0 to 5 V into open circuit, 0 to 2.5 V into 50 Ω |
Technology
Mixed Signal Oscilloscope
Applications
Embedded system design, mixed-signal debugging, serial bus testing, automotive and industrial electronics repair