The Keysight Technologies MSO6034A is a 300 MHz, 4 analog plus 16 digital channel Mixed Signal Oscilloscope from the InfiniiVision 6000 Series. Featuring MegaZoom III deep memory, a fast 100,000 waveforms/sec update rate, and a high-definition color display with 256 levels of intensity, it delivers outstanding signal insight for debugging analog, digital, and serial bus designs.

Specifications

General

ParameterValue
InterfacesLAN (LXI Class C), USB 2.0 (Host and Device), GPIB, XGA Video Output
Display6.3-inch diagonal color active matrix TFT LCD, 640 x 480 (VGA)

Physical

ParameterValue
Power Supply100 - 240 V AC, 50/60 Hz (also 100 - 120 V AC, 400 Hz); 120 W maximum
Operating Temperature0 to 55 °C
Dimensions (W×H×D)354 mm × 188 mm × 174 mm
Weight4.9 kg

Analog Vertical System

ParameterValue
Analog Input Channels4
Analog Bandwidth (-3 dB)300 MHz
Calculated Rise Time (10% to 90%)1.17 ns
Input CouplingAC, DC
Input Impedance1 MΩ ± 1% || 14 pF, or 50 Ω ± 1.5%
Input Sensitivity Range2 mV/div to 5 V/div (1 MΩ), 2 mV/div to 1 V/div (50 Ω)
Vertical Resolution8 bits
Maximum Input Voltage (Analog)CAT I 400 Vpk (1 MΩ), 5 Vrms (50 Ω)
DC Gain Accuracy±2% of full scale
Offset Range±5 V (< 200 mV/div), ±100 V (≥ 200 mV/div) for 1 MΩ
Hardware Bandwidth Limits20 MHz selectable
Channel-to-Channel Isolation≥ 40 dB from DC to 300 MHz

Digital Vertical System

ParameterValue
Digital Input Channels16
Threshold GroupingsPod 1 (D7 - D0), Pod 2 (D15 - D8)
Threshold SelectionsTTL, CMOS, ECL, User-defined
User-Defined Threshold Range±8.0 V in 10 mV steps
Threshold Accuracy±(100 mV + 3% of threshold setting)
Maximum Input Voltage (Digital)±40 V peak CAT I
Input Dynamic Range±10 V about threshold
Minimum Voltage Swing500 mV pp
Input Impedance (Digital)100 kΩ ± 2% || ~8 pF
Channel-to-Channel Skew2 ns typical, 3 ns maximum

Horizontal System and Acquisition

ParameterValue
Maximum Analog Sample Rate2 GSa/s (half-channel interleaved), 1 GSa/s (all-channels)
Time Base Range2 ns/div to 50 s/div
Time Base Accuracy15 ppm (0.0015%)
Channel Deskew Range±100 ns

Trigger System

ParameterValue
Trigger SourcesAnalog channels (1 - 4), digital channels (D0 - D15), Line, External
Trigger ModesAuto, Normal, Single
Trigger CouplingAC, DC, LF Reject, HF Reject, Noise Reject
Trigger Holdoff Range60 ns to 10 s
Trigger SensitivityAnalog: greater of 0.6 div or 5.0 mV (< 10 MHz), greater of 1.0 div or 10.0 mV (10 MHz to max bandwidth); External: 100 mV (DC to 100 MHz), 250 mV (100 MHz to max bandwidth)
Edge TriggeringRising, falling, alternating on any source
Pulse Width TriggeringTrigger on positive or negative pulses from 15 ns to 10 s
Pattern/State TriggeringTrigger on enter, exit, or duration of ANDed patterns (H, L, X) across analog and digital channels; State clock on any channel (edge)
TV/Video TriggeringNTSC, PAL, SECAM, HDTV (480p, 576p, 720p, 1080i, 1080p); triggering on positive or negative sync, field, or line
Duration/Timeout TriggeringTrigger on pattern entered/exited and present for > or < time (15 ns to 10 s)
Sequence/Runt TriggeringSequence triggering: Arm on event A, trigger on event B after delay or occurrence count
Serial Bus Triggering OptionsI2C, SPI, CAN, LIN, USB, FlexRay (standard or optional depending on protocol)

Acquisition Modes

ParameterValue
Normal ModeAcquires and displays waveforms at full sample rate
Peak Detect ModeCaptures glitches as narrow as 1 ns at all sweep speeds
Averaging ModeSelectable from 2 to 16,384 in powers of 2
High Resolution ModeReal-time boxcar average reduces random noise, increasing vertical resolution up to 12 bits
Segmented Memory ModeCaptures up to 1000 segments with time-tagging of each segment
Roll ModeSlow sweep speeds of 50 ms/div to 50 s/div

Waveform Measurements and Analysis

ParameterValue
Voltage MeasurementsPeak-to-Peak, Maximum, Minimum, Amplitude, Top, Base, Overshoot, Preshoot, Average, RMS
Time and Frequency MeasurementsPeriod, Frequency, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle
Mixed-Signal MeasurementsDelay, Phase, Channel-to-Channel Time Measurements
Cursor TypesManual (X and Y), Track Waveform, Auto Measurements
Waveform Math OperationsAddition, Subtraction, Multiplication, FFT
FFT Window TypesHanning, Flat Top, Rectangular
FFT Resolution and Frequency SpanUp to 1024 points resolution, span from DC to Nyquist frequency
Measurement StatisticsDisplay of Mean, Min, Max, Standard Deviation, and Count
Mask Testing CompatibilityOption LMT (Limit Mask Testing) compatible

Display and User Interface

ParameterValue
Display TypeColor active matrix TFT LCD
Display Size (Diagonal)6.3 inches (160 mm)
Display Resolution640 x 480 (VGA)
Waveform Update Rate100,000 waveforms/sec
Waveform Intensity Levels32 levels of intensity gradation
Graticule Options8 x 10 grid, framing, grid, none
Local Language User InterfaceMultiple languages supported (English, French, German, Spanish, Japanese, Simplified Chinese, Traditional Chinese, Korean, Russian, Italian, Portuguese)

Connectivity and Interfaces

ParameterValue
USB Host Ports2 x USB 2.0 host ports (one on front panel, one on rear panel) supporting flash drives
USB Device Port1 x USB 2.0 high-speed device port on rear panel for PC connectivity or printing
LAN Port (LXI Compliant)RJ-45 10/100Base-TX, LXI Class C compliant
GPIB Interface PortIEEE 488.2 interface on rear panel
External Trigger Input PortBNC connector on rear panel
Trigger Out/Calibrator OutputBNC auxiliary output, can be configured as Trigger Out, Mask Out, or 10 MHz Reference Clock Out
Video Output Port15-pin D-sub (VGA resolution)

Physical and Power Specifications

ParameterValue
Power Source Voltage100 V to 240 V AC auto-ranging
Power Line Frequency Range50 Hz to 60 Hz (100 V to 240 V), 400 Hz (100 V to 120 V)
Power Consumption120 W maximum
Form FactorBenchtop, stackable
Kensington Lock SlotStandard rear-panel slot

Environmental and Compliance

ParameterValue
Storage Temperature-40 °C to +70 °C
Operating Humidity95% relative humidity at up to +40 °C
Operating AltitudeUp to 4,600 m (15,000 ft)
Safety CertificationsUL 61010-1, CAN/CSA-C22.2 No. 61010-1, EN 61010-1
Electromagnetic Compatibility (EMC)IEC 61326-1, EN 61326-1, CISPR 11 Class A

Accessories and Options

ParameterValue
Standard Included Analog Probes4 x 10073C 10:1 passive probes (500 MHz)
Standard Included Digital Probe Kit1 x 16-channel digital probe kit (54620-68701)
Passive Probe CompatibilityAutoProbe interface or standard BNC
Active Probe Interface SupportAgilent AutoProbe interface
Serial Decode Software UpgradesI2C/SPI (N5423A), CAN/LIN (N5424A), FlexRay (N5432A)
Rackmount Kit AccessoriesOption 1CM (or N2916B) rackmount kit

Performance Architecture

ParameterValue
Acquisition TechnologyMegaZoom III deep memory

Connectivity and Data Storage

ParameterValue
Web Browser Remote ControlBuilt-in web server allows remote control via standard web browser
Programming Language CompatibilitySCPI, Agilent 54620/54640 Series
LXI Class ComplianceLXI Class C
Exportable Waveform FormatsCSV, ASCII, BIN
Exportable Image FormatsBMP, PNG
Save/Recall Capabilities10 nonvolatile setups and waveforms, 1 reference waveform

General Technical Specifications

ParameterValue
Real-Time ClockBuilt-in, battery-backed
Built-in Help SystemAvailable in 11 languages
Security FeaturesOption SEC (Secure Environment Mode) for erasing user memory

Environmental & Reliability

ParameterValue
Vibration and Shock ComplianceMIL-PRF-28800F Class 3

Digital Channels

ParameterValue
Minimum Detectable Pulse Width (Digital)5 ns
Digital Channel Threshold Resolution10 mV
Digital Channel Input Resistance100 k̩ (±2%)
Digital Channel Input Capacitance~8 pF
Analog-to-Digital Channel Skew2 ns (typical)

Inputs & Outputs

ParameterValue
10 MHz Reference Input Frequency10 MHz ± 5 ppm

Storage

ParameterValue
Internal Storage Locations10 setups and waveforms

Triggering

ParameterValue
Trigger Level Range (Analog Channels)±6 divisions from center screen
External Trigger Maximum Input Voltage150 Vrms CAT II (1 M̩)

Power & Environmental

ParameterValue
Mains Pollution Degree CompliancePollution Degree 2

Technology

Mixed Signal Oscilloscope (MSO)

Applications

Electronic design, debugging, automotive serial buses, and embedded system troubleshooting