The Keysight Technologies (formerly Agilent HP) MSO6054A is a 500 MHz, 4 analog channel and 16 digital channel Mixed Signal Oscilloscope. Built with MegaZoom III technology, it offers an uncompromised waveform update rate of up to 100,000 waveforms per second, a standard 8 Mpts deep memory, and a 6.3-inch high-definition XGA display with 256 intensity levels. It is designed to debug demanding analog, digital, and serial bus designs in one portable instrument.

Specifications

General

ParameterValue
Display6.3-inch (160 mm) diagonal color XGA (1024 x 768) TFT LCD with 256 intensity levels

Vertical System - Analog Channels

ParameterValue
Analog Bandwidth500 MHz
Number of Analog Channels4
Calculated Rise Time~700 ps (0.35 / Bandwidth)
Vertical Resolution8 bits (up to 12 bits in High Resolution mode)

Vertical System - Digital Channels

ParameterValue
Number of Digital Channels16

Acquisition System

ParameterValue
Maximum Real-Time Sample Rate (Analog)4 GSa/s (interleaved on 2 channels), 2 GSa/s (on 4 channels)
Maximum Real-Time Sample Rate (Digital)2 GSa/s (interleaved on 8 channels), 1 GSa/s (on 16 channels)
Maximum Memory Depth (Analog)8 Mpts (interleaved on 2 channels), 4 Mpts (on 4 channels)
High Resolution ModeReal-time boxcar filtering yields up to 12 bits of resolution
Waveform Update Rate100,000 waveforms/sec

Trigger System

ParameterValue
Trigger ModesAuto, Normal, Single
Trigger CouplingAC, DC, LF Reject, HF Reject, Noise Reject
Edge TriggeringRising, falling, or alternating edges on any source
Trigger Level Range (Internal)±6 divisions from center of screen

Waveform Analysis and Measurements

ParameterValue
Hardware CursorsX1, X2, Y1, Y2 with readout of delta and 1/delta
Automatic Voltage MeasurementsPeak-to-Peak, Max, Min, Amplitude, Top, Base, Overshoot, Preshoot, Average, RMS
Automatic Time MeasurementsFrequency, Period, +Width, -Width, Duty Cycle, Rise Time, Fall Time, Delay, Phase
FFT Window TypesHanning, Flat Top, Rectangular, Blackman-Harris

Connectivity and I/O Interfaces

ParameterValue
USB Device Port1 port (rear panel), Type B for remote control
LXI Compliance ClassClass C compliant
External Video OutputXGA 15-pin D-sub (rear panel)

Physical, Power, and Environmental

ParameterValue
Operating AltitudeUp to 4,600 m (15,000 ft)

Accessories Included

ParameterValue
Standard Analog Probe10073C (10:1 passive probe, 500 MHz, 4 included)
Standard Digital Probe Kit54620-68701 (16-channel digital cable kit, 1 included)

Power Requirements

ParameterValue
AC Input Voltage Range100 - 120 V AC at 50/60/400 Hz, or 100 - 240 V AC at 50/60 Hz
Maximum Power Consumption120 W

Environmental & Mechanical

ParameterValue
Non-Operating VibrationAgilent Class B1, random 5 - 500 Hz, 10 min per axis, 2.41 g (rms)
Operating ShockAgilent Class B1, half-sine pulse, 30 g, 11 ms duration

System Features

ParameterValue
Calibration Interval1 year
Real-Time ClockBuilt-in, battery-backed
Standard GUI LanguagesEnglish, French, German, Italian, Spanish, Japanese, Korean, Portuguese, Russian, Simplified Chinese, Traditional Chinese

Measurement Statistics

ParameterValue
Available Statistical MetricsMean, standard deviation, minimum, maximum, and count
Simultaneous MeasurementsUp to 4 displayed simultaneously

Hardware Connectivity

ParameterValue
AutoProbe InterfaceSupported on all analog channels

Power Specifications

ParameterValue
Line Frequency Range50/60 Hz (100 to 240 VAC) or 400 Hz (100 to 120 VAC)

Environmental & Safety

ParameterValue
Pollution DegreePollution Degree 2
Installation CategoryCAT II

Technology

Mixed Signal Oscilloscope (MSO)

Applications

Mixed-signal design and debug, serial bus triggering and analysis, automotive and aerospace system testing, power analysis, FPGA debugging.