The Keysight Technologies (Agilent) MSO7104B is a 1 GHz, 4-analog-channel plus 16-digital-channel Mixed Signal Oscilloscope in the InfiniiVision 7000B Series. Featuring a large 12.1" XGA display and deep MegaZoom III memory, this instrument delivers high-speed hardware-accelerated acquisition up to 100,000 waveforms per second, ensuring excellent signal visibility and troubleshooting capabilities.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | 3 x USB 2.0 Host (1 front, 2 rear), 1 x USB 2.0 Device, LAN (10/100Base-T, LXI Class C), VGA video output, Auxiliary Output, External Trigger Input |
| Display | 12.1-inch diagonal color TFT LCD with XGA (1024 x 768) resolution and 256 intensity levels |
| Calibration Interval | 2 years |
| Real-Time Clock | Yes, built-in |
| Supported Languages (Built-in Help) | 11 languages (English, Simplified Chinese, Traditional Chinese, French, German, Italian, Japanese, Korean, Portuguese, Russian, Spanish) |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 100 - 120 V (50/60/400 Hz) / 100 - 240 V (50/60 Hz) auto-ranging, 120 W maximum power consumption |
| Operating Temperature | 0 °C to +55 °C |
| Dimensions (W×H×D) | 454 mm x 298 mm x 172 mm |
| Weight | 5.9 kg |
Key Performance Specifications
| Parameter | Value |
|---|---|
| Analog Bandwidth (-3 dB) | 1 GHz |
| Calculated Rise Time (10% to 90%) | 350 ps |
| Number of Analog Channels | 4 |
| Number of Digital Channels (MSO) | 16 |
| Maximum Analog Sample Rate | 4 GSa/s (half-channel interleaved), 2 GSa/s (each channel) |
| Maximum Digital Sample Rate | 2 GSa/s |
| Standard Memory Depth | 8 Mpts MegaZoom III (half-channel interleaved), 4 Mpts (each channel) |
| Maximum Waveform Update Rate | Up to 100,000 waveforms/sec |
Vertical System - Analog Channels
| Parameter | Value |
|---|---|
| Vertical Resolution | 8 bits |
| Input Sensitivity Range | 2 mV/div to 5 V/div (1 MΩ), 2 mV/div to 1 V/div (50 Ω) |
| Maximum Input Voltage | CAT I 300 Vrms, 400 Vpk (1 MΩ); 5 Vrms (50 Ω) |
| Input Coupling | AC, DC |
| Input Impedance | 1 MΩ ± 1% || 14 pF, or 50 Ω ± 1.5% |
| Hardware Bandwidth Limits | 20 MHz selectable |
| DC Vertical Gain Accuracy | ±2.0% of full scale |
| Channel-to-Channel Isolation | ≥ 40 dB from DC to 1 GHz |
| Offset Range (50 Ω) | 2 mV/div to 200 mV/div: ±2 V; 201 mV/div to 1 V/div: ±5 V |
| Offset Range (1 MΩ) | 2 mV/div to 200 mV/div: ±5 V; 201 mV/div to 5 V/div: ±100 V |
| Dynamic Range | ±8 div from center-screen |
| Probing Interface | AutoProbe |
Vertical System - Digital Channels
| Parameter | Value |
|---|---|
| Input Channels (Digital) | 16 digital channels (D0 to D15) |
| Threshold Selections | TTL, CMOS, ECL, User-Defined |
| User-Defined Threshold Range | ±8.0 V in 10 mV steps |
| Threshold Accuracy | ±(100 mV + 3% of threshold setting) |
| Maximum Input Voltage (Digital) | ±40 V peak |
| Input Impedance (Digital) | 100 kΩ ± 2% || ~8 pF |
| Minimum Detectable Pulse Width | 2 ns |
| Channel-to-Channel Skew (Digital to Digital) | 2 ns typical |
| Channel-to-Channel Skew (Analog to Digital) | 2.5 ns typical |
| Digital Channel Minimum Input Voltage Swing | 500 mV p-p |
| Digital Channel Maximum Toggle Rate | 250 MHz |
Horizontal System (Timebase)
| Parameter | Value |
|---|---|
| Timebase Range | 200 ps/div to 50 s/div |
| Timebase Accuracy | ±25 ppm (0.0025%) |
| Channel-to-Channel Deskew Range | ±100 ns |
| Horizontal Modes | Main, Zoom, Roll, XY |
Acquisition System
| Parameter | Value |
|---|---|
| Acquisition Modes | Normal, Peak Detect, Averaging, High Resolution, Segmented Memory |
| Peak Detect Glitch Capture Minimum | 250 ps (at 4 GSa/s) |
| Averaging Factor Selections | 2 to 65,536 (in powers of 2) |
| Segmented Memory Maximum Segments | Up to 2,000 segments |
Trigger System
| Parameter | Value |
|---|---|
| Trigger Sources | Analog channels, Digital channels, Line, External |
| Trigger Modes | Auto, Normal, Single |
| Trigger Coupling | AC, DC, LF Reject, HF Reject, Noise Reject |
| Trigger Holdoff Range | 60 ns to 10 s |
| Trigger Sensitivity | 0.6 div or 5 mV (DC to 100 MHz), 1.0 div or 10 mV (100 MHz to max bandwidth) |
| Trigger Level Range (Analog) | ±6 div from center of screen |
| Standard Trigger Types | Edge, Pulse Width, Pattern, TV/Video, Duration, Sequence |
| Trigger Jitter | 15 ps rms |
Waveform Measurements and Math
| Parameter | Value |
|---|---|
| Automatic Voltage Measurements | Peak-to-peak, Max, Min, Amplitude, Top, Base, Overshoot, Preshoot, Average, RMS |
| Automatic Time Measurements | Period, Frequency, Rise Time, Fall Time, +Width, -Width, Duty Cycle, Delay, Phase |
| Waveform Math Operators | Addition, Subtraction, Multiplication, FFT |
| FFT Window Functions | Hanning, Flat Top, Rectangular, Blackman-Harris |
Connectivity and Interfaces
| Parameter | Value |
|---|---|
| USB Host Ports (Front & Rear) | 3 x USB 2.0 host (1 front, 2 rear) |
| USB Device Port | 1 x USB 2.0 device (rear) |
| LAN Port (LXI Compliant) | 10/100Base-T, RJ-45, LXI Class C |
| External Trigger Input | Rear panel, BNC |
| Auxiliary Output (Trigger Out / Calibration) | Rear panel BNC (Trigger out or Calibration) |
| VGA Video Output | 15-pin D-sub, rear panel |
Power and Environmental Specifications
| Parameter | Value |
|---|---|
| Non-Operating Temperature Range | -40 °C to +70 °C |
| Operating Humidity Range | Up to 95% RH at +40 °C (non-condensing) |
| Operating Altitude | Up to 4,000 m (13,000 ft) |
| Electromagnetic Compatibility (EMC) | IEC 61326-1, EN 61326-1 |
| Safety Standards | UL61010-1, CAN/CSA-C22.2 No. 61010-1, EN61010-1 |
Physical Characteristics
| Parameter | Value |
|---|---|
| Shipping Weight | 9.3 kg (20.5 lbs) |
| Kensington Lock Slot | Rear panel |
Accessories
| Parameter | Value |
|---|---|
| Standard Passive Probes | Four N2890A 10:1 500 MHz passive probes |
| Standard Logic Probe Cable | 54620-68701 16-channel logic probe and accessory kit |
Environmental
| Parameter | Value |
|---|---|
| Acoustic Noise | 35 dBA at front panel |
| Vibration and Shock | Meets MIL-PRF-28800F Class 3 random vibration |
| Pollution Degree | Pollution Degree 2 |
| Overvoltage Category | CAT II 300 V |
Power
| Parameter | Value |
|---|---|
| Maximum Power Consumption | 120 W |
| AC Input Power Voltage Range | 100 to 120 V AC (50/60/400 Hz), 100 to 240 V AC (50/60 Hz) |
Outputs
| Parameter | Value |
|---|---|
| Calibration Output | ~1.2 V p-p into 1 MΩ, ~1.2 kHz square wave |
Interfaces
| Parameter | Value |
|---|---|
| Optional GPIB Interface | Supported via N2727A GPIB module |
Display
| Parameter | Value |
|---|---|
| Display Size | 12.1 inches (307 mm) diagonal |
| Display Resolution | 1024 x 768 pixels (XGA) |
| Display Intensity Levels | 256 levels |
Triggering
| Parameter | Value |
|---|---|
| External Trigger Input Impedance | Not applicable (external trigger is only available on 2-channel models) |
| External Trigger Maximum Input Voltage | Not applicable (external trigger is only available on 2-channel models) |
| External Trigger Level Range | Not applicable (external trigger is only available on 2-channel models) |
| Optional Serial Triggering and Decode | I²C, SPI, UART/RS-232, CAN, LIN, FlexRay, I²S, MIL-STD-1553 |
Digital Channels
| Parameter | Value |
|---|---|
| Digital Channel Threshold Resolution | 10 mV |
Connectivity
| Parameter | Value |
|---|---|
| Web Viewer Control | Supported via standard web browser |
Technology
Mixed Signal Oscilloscope (MSO)
Applications
Design, debugging, and testing of mixed-signal, digital, and analog circuits.