The Keysight (Agilent) Infiniium MSO8104A is a 1 GHz, 4+16 channel mixed signal oscilloscope offering high-performance signal analysis powered by MegaZoom technology. Designed for embedded system debug, it features up to 128 Mpts of deep memory, an open Windows XP Pro environment, and standard touchscreen operation to enable detailed time-correlated viewing across 20 channels.

Specifications

Vertical System - Analog Channels

ParameterValue
Analog Bandwidth1 GHz
Calculated Rise Time350 ps
Input Channels4 analog channels
Input Coupling1 MOhm (AC, DC), 50 Ohm (DC)
Vertical Resolution8 bits (up to 12 bits with high resolution mode)

Vertical System - Digital Channels

ParameterValue
Digital Channels16 digital channels
Threshold GroupingsTwo groups of 8 channels (D0-D7, D8-D15)
Threshold SelectionsTTL, CMOS, ECL, PECL, User-defined
User-Defined Threshold Range+/-8.0 V in 10 mV increments
Threshold Accuracy+/-(100 mV + 3% of threshold setting)
Maximum Input Voltage (Digital)+/-40 V peak
Minimum Voltage Swing500 mV peak-to-peak
Input Impedance (Digital)100 kOhm +/-2% (~8 pF)
Channel-to-Channel Skew (Digital)2 ns typical

Horizontal System & Acquisition

ParameterValue
Real-Time Sample Rate - 2 Channels4 GSa/s
Real-Time Sample Rate - 4 Channels2 GSa/s
Maximum Memory Depth - Standard1 Mpts (per channel), 2 Mpts (interleaved)
Maximum Memory Depth - OptionalUp to 128 Mpts (interleaved), 64 Mpts (per channel)

Acquisition Modes

ParameterValue
Real-Time ModeYes
Equivalent-Time ModeYes (up to 250 GSa/s)
Average ModeYes (selectable from 2 to 4096)
High-Resolution ModeYes (up to 12 bits)

Trigger System

ParameterValue
Trigger ModesAuto, Triggered, Single

Display & User Interface

ParameterValue
Operating SystemWindows XP Pro

Connectivity & Interfaces

ParameterValue
LAN Port Type10/100Base-T RJ-45
GPIB InterfaceIEEE-488 standard

Power & Environmental

ParameterValue
Storage Temperature-40 to +70 deg C
Operating HumidityUp to 95% relative humidity at +40 deg C (non-condensing)
Operating AltitudeUp to 4,600 m (15,000 ft)
Maximum Power Consumption440 W
Vibration ComplianceMIL-PRF-28800F Class 3 random

Ordering Information & Options

ParameterValue
Standard Included Probes4 x Agilent 10073C 10:1 passive probes, 1 x 16-channel digital probe kit
Active Probe Interface SupportInfiniiMax active probe interface (Autoprobe interface)

Computer System

ParameterValue
LXI ComplianceClass C

Technology

Mixed Signal Oscilloscope

Applications

Embedded debug, mixed signal design, protocol decoding, and high-speed signal analysis