The Keysight (Agilent) Infiniium MSO8104A is a 1 GHz, 4+16 channel mixed signal oscilloscope offering high-performance signal analysis powered by MegaZoom technology. Designed for embedded system debug, it features up to 128 Mpts of deep memory, an open Windows XP Pro environment, and standard touchscreen operation to enable detailed time-correlated viewing across 20 channels.
Specifications
Vertical System - Analog Channels
| Parameter | Value |
|---|---|
| Analog Bandwidth | 1 GHz |
| Calculated Rise Time | 350 ps |
| Input Channels | 4 analog channels |
| Input Coupling | 1 MOhm (AC, DC), 50 Ohm (DC) |
| Vertical Resolution | 8 bits (up to 12 bits with high resolution mode) |
Vertical System - Digital Channels
| Parameter | Value |
|---|---|
| Digital Channels | 16 digital channels |
| Threshold Groupings | Two groups of 8 channels (D0-D7, D8-D15) |
| Threshold Selections | TTL, CMOS, ECL, PECL, User-defined |
| User-Defined Threshold Range | +/-8.0 V in 10 mV increments |
| Threshold Accuracy | +/-(100 mV + 3% of threshold setting) |
| Maximum Input Voltage (Digital) | +/-40 V peak |
| Minimum Voltage Swing | 500 mV peak-to-peak |
| Input Impedance (Digital) | 100 kOhm +/-2% (~8 pF) |
| Channel-to-Channel Skew (Digital) | 2 ns typical |
Horizontal System & Acquisition
| Parameter | Value |
|---|---|
| Real-Time Sample Rate - 2 Channels | 4 GSa/s |
| Real-Time Sample Rate - 4 Channels | 2 GSa/s |
| Maximum Memory Depth - Standard | 1 Mpts (per channel), 2 Mpts (interleaved) |
| Maximum Memory Depth - Optional | Up to 128 Mpts (interleaved), 64 Mpts (per channel) |
Acquisition Modes
| Parameter | Value |
|---|---|
| Real-Time Mode | Yes |
| Equivalent-Time Mode | Yes (up to 250 GSa/s) |
| Average Mode | Yes (selectable from 2 to 4096) |
| High-Resolution Mode | Yes (up to 12 bits) |
Trigger System
| Parameter | Value |
|---|---|
| Trigger Modes | Auto, Triggered, Single |
Display & User Interface
| Parameter | Value |
|---|---|
| Operating System | Windows XP Pro |
Connectivity & Interfaces
| Parameter | Value |
|---|---|
| LAN Port Type | 10/100Base-T RJ-45 |
| GPIB Interface | IEEE-488 standard |
Power & Environmental
| Parameter | Value |
|---|---|
| Storage Temperature | -40 to +70 deg C |
| Operating Humidity | Up to 95% relative humidity at +40 deg C (non-condensing) |
| Operating Altitude | Up to 4,600 m (15,000 ft) |
| Maximum Power Consumption | 440 W |
| Vibration Compliance | MIL-PRF-28800F Class 3 random |
Ordering Information & Options
| Parameter | Value |
|---|---|
| Standard Included Probes | 4 x Agilent 10073C 10:1 passive probes, 1 x 16-channel digital probe kit |
| Active Probe Interface Support | InfiniiMax active probe interface (Autoprobe interface) |
Computer System
| Parameter | Value |
|---|---|
| LXI Compliance | Class C |
Technology
Mixed Signal Oscilloscope
Applications
Embedded debug, mixed signal design, protocol decoding, and high-speed signal analysis