The Keysight (formerly Agilent) N5183A MXG is a microwave analog signal generator providing precise and reliable RF stimulus for broadband component manufacturing and test up to 40 GHz. With rapid frequency switching speeds and high output power options, it is designed for demanding high-throughput applications like antenna manufacturing and device characterization.
Specifications
Frequency
| Parameter | Value |
|---|---|
| Minimum Frequency | 100 kHz |
| Maximum Frequency | 40 GHz (Option 540) |
| Frequency Resolution | 0.01 Hz |
Modulation
| Parameter | Value |
|---|---|
| Modulation | AM, FM, Phase (ΦM), and Pulse modulation |
| Sweep Modes | Digital step and list sweep |
| AM, FM, Phase Modulation | Requires Option UNT |
| Pulse Modulation | Requires Option UNU (Standard) or UNW (Narrow) |
| Pulse Modulation On/Off Ratio | > 80 dB (typical, option dependent) |
General
| Parameter | Value |
|---|---|
| Reference Oscillator | 10 MHz |
| Interfaces | 100BaseT LAN, USB 2.0, GPIB |
Physical
| Parameter | Value |
|---|---|
| Dimensions (W×H×D) | 426 × 88 × 432 mm |
| Weight | 13.8 kg |
| RF Output Connector | 3.5 mm (m) for 20 GHz option; 2.4 mm (m) for 31.8 / 40 GHz options |
Frequency Specifications
| Parameter | Value |
|---|---|
| Frequency Options | 20 GHz (Option 520), 31.8 GHz (Option 532), or 40 GHz (Option 540) |
| Frequency Switching Speed | ≤ 900 µs (≤ 600 µs typical) |
| Internal Reference Frequency | 10 MHz |
Amplitude and Output Specifications
| Parameter | Value |
|---|---|
| Output Impedance | 50 Ω (nominal) |
Pulse Modulation
| Parameter | Value |
|---|---|
| Minimum Pulse Width | 20 ns |
Sweep Capabilities
| Parameter | Value |
|---|---|
| Sweep Types | Step, List |
Remote Control and Software
| Parameter | Value |
|---|---|
| Remote Interfaces | LAN (100BaseT), USB 2.0, GPIB |
| LXI Compliance Class | LXI Class C |
| Supported Programming Languages | SCPI |
| Software/Driver Support | IVI-COM drivers |
| Legacy Instrument Emulation Modes | Backward compatible with PSG, 8340, 8360, and 8370 Series |
Physical and Power Specifications
| Parameter | Value |
|---|---|
| Form Factor / Rack Units | 2 RU |
Environmental
| Parameter | Value |
|---|---|
| Operating Temperature | 0 to 55 °C |
| Operating Altitude | Up to 4,600 meters (15,000 ft) |
Amplitude & Power
| Parameter | Value |
|---|---|
| Amplitude Resolution | 0.01 dB |
Frequency & Phase
| Parameter | Value |
|---|---|
| External Reference Input Frequency | 10 MHz (standard), 1 to 50 MHz (with Option 1ER) |
Sweep
| Parameter | Value |
|---|---|
| List Sweep Maximum Points | 3201 |
| Step Sweep Maximum Points | 65535 |
| Sweep Trigger Sources | Free run, Trigger Key, External, Timer, Bus |
Compliance & Safety
| Parameter | Value |
|---|---|
| EMC Compliance | IEC/EN 61326-1 |
| Safety Compliance | IEC/EN 61010-1 |
Technology
Microwave Analog
Applications
Broadband component manufacturing, antenna test, LO substitution, CW interferer, and device characterization