The Keysight U2723A is a 3-channel USB Modular Source Measure Unit (SMU) designed for precise voltage and current sourcing and measurement. With its 4-quadrant operating capability, each of the three channels can source or sink up to ±20 V and ±120 mA. A defining feature of the U2723A is its embedded test scripting capability, allowing for standalone test sequences of up to 10,000 steps without continuous host PC polling. Operating with high-speed USB 2.0 connectivity, the U2723A is isolated for robust safety and noise reduction, making it ideal for semiconductor characterization, educational laboratories, and high-throughput automated test environments.

Specifications

General

ParameterValue
InterfacesUSB 2.0 High Speed (USBTMC-USB488), System Synchronous Interface (SSI)
DisplayNone (status LEDs only)
Warm-up Time30 minutes
Recommended Calibration Interval1 year

Physical

ParameterValue
Power Supply12 VDC via external AC/DC power adapter (100 to 240 VAC, 50/60 Hz input)
Operating Temperature0 to 50 °C
Dimensions (W×H×D)117.00 mm × 41.00 mm × 180.00 mm (chassis without bumpers)
Weight0.68 kg
Security FeatureKensington security slot

Core Signal and Electrical Performance

ParameterValue
Number of Channels3
Operating Quadrants4-quadrant (Source and Sink)
Output Voltage Range-20 V to +20 V (per channel)
Output Current Range-120 mA to +120 mA (per channel)
Maximum Power per Channel2.4 W
Voltage Programming Ranges±2 V, ±20 V
Current Programming Ranges±1 µA, ±10 µA, ±100 µA, ±1 mA, ±10 mA, ±120 mA
Channel-to-Channel Isolation Voltage60 VDC
Voltage Programming Resolution (2 V Range)100 µV
Voltage Programming Resolution (20 V Range)1 mV
Voltage Measurement Resolution (2 V Range)100 µV
Voltage Measurement Resolution (20 V Range)1 mV
Current Programming Resolution (1 µA Range)100 pA
Current Programming Resolution (10 µA Range)1 nA
Current Programming Resolution (100 µA Range)10 nA
Current Programming Resolution (1 mA Range)100 nA
Current Programming Resolution (10 mA Range)1 µA
Current Programming Resolution (120 mA Range)10 µA
Current Measurement Resolution (1 µA Range)100 pA
Current Measurement Resolution (10 µA Range)1 nA
Current Measurement Resolution (100 µA Range)10 nA
Current Measurement Resolution (1 mA Range)100 nA
Current Measurement Resolution (10 mA Range)1 µA
Current Measurement Resolution (120 mA Range)10 µA
Voltage Programming Accuracy (2 V Range)±(0.075% + 1.5 mV)
Voltage Programming Accuracy (20 V Range)±(0.05% + 10 mV)
Voltage Measurement Accuracy (2 V Range)±(0.075% + 1.5 mV)
Voltage Measurement Accuracy (20 V Range)±(0.05% + 10 mV)
Current Programming Accuracy (1 µA Range)±(0.085% + 0.85 nA)
Current Programming Accuracy (10 µA Range)±(0.085% + 8.5 nA)
Current Programming Accuracy (100 µA Range)±(0.075% + 75 nA)
Current Programming Accuracy (1 mA Range)±(0.075% + 750 nA)
Current Programming Accuracy (10 mA Range)±(0.075% + 7.5 µA)
Current Programming Accuracy (120 mA Range)±(0.1% + 100 µA)
Current Measurement Accuracy (1 µA Range)±(0.085% + 0.85 nA)
Current Measurement Accuracy (10 µA Range)±(0.085% + 8.5 nA)
Current Measurement Accuracy (100 µA Range)±(0.075% + 75 nA)
Current Measurement Accuracy (1 mA Range)±(0.075% + 750 nA)
Current Measurement Accuracy (10 mA Range)±(0.075% + 7.5 µA)
Current Measurement Accuracy (120 mA Range)±(0.1% + 100 µA)

Measurement Capabilities and Timing

ParameterValue
Embedded Test Scripting MemoryUp to 10,000 steps
Maximum Measurement Speed18 readings/s

Connectivity, Ports, and Interfaces

ParameterValue
Primary Connection InterfaceUSB 2.0 (Mini-B connector)
Multi-Unit SynchronizationSystem Synchronous Interface (SSI)
Output Connector TypePlug-in terminal block

User Interface and Software Control

ParameterValue
Programming Language CompatibilitySCPI
Standard Software CompatibilityKeysight Measurement Manager (KMM)
Software Driver SupportIVI-COM, IVI-C, LabVIEW

Power and Electrical Specifications

ParameterValue
Power Supply Input Voltage12 VDC
Maximum Current Consumption3.0 A
Power Adapter Requirements100 to 240 VAC, 50/60 Hz (AC/DC Adapter included)

Physical and Mechanical Attributes

ParameterValue
Form FactorUSB Modular / Benchtop
Chassis Width117.00 mm
Chassis Height41.00 mm
Chassis Depth180.00 mm
Chassis Weight0.68 kg

Environmental and Compliance Standards

ParameterValue
Storage Temperature Range-20 to 70 °C
Operating Humidity Range20% to 85% RH (non-condensing)
Storage Humidity Range5% to 90% RH (non-condensing)
Maximum Operating Altitude2,000 m
Safety Compliance StandardsIEC 61010-1, EN 61010-1
EMC Compliance StandardsIEC 61326-1, EN 61326-1, ICES-001, AS/NZS CISPR 11

Configurations, Options, and Accessories

ParameterValue
Standard Included AccessoriesAC/DC Power Adapter, Power Cord, USB Standard-A to Mini-B Cable, L-Mount Kit, Quick Start Guide, Keysight Measurement Manager (KMM) software, Calibration Certificate

Pulse Generation

ParameterValue
Minimum Pulse Width500 µs
Maximum Pulse Width65.535 s
Pulse Width Resolution100 µs
Minimum Pulse Period1 ms
Maximum Pulse Period65.535 s

Regulation

ParameterValue
Voltage Line Regulation0.01% + 100 µV
Current Line Regulation0.01% + 100 pA
Voltage Load Regulation0.01% + 100 µV
Current Load Regulation0.01% + 100 pA

Measurement Performance

ParameterValue
Voltmeter Input Impedance> 10 GΩ

Noise and Ripple

ParameterValue
Peak-to-Peak Voltage Noise (2 V Range, 0.1 Hz to 10 Hz)< 50 µV
Peak-to-Peak Voltage Noise (20 V Range, 0.1 Hz to 10 Hz)< 100 µV

Isolation & Safety

ParameterValue
Maximum Common Mode Voltage±60 VDC

Guard & Sense

ParameterValue
Maximum Sense Lead Resistance1 Ω (for rated accuracy)
Sensing Modes2-wire (local) or 4-wire (remote) sensing

Source Performance

ParameterValue
Voltage Source Overshoot< 1% (typical, with resistive load)
Voltage Rise Time< 1.0 ms (typical, 10% to 90% into 166 Ω load)
Current Rise Time< 1.0 ms (typical, 10% to 90% into 166 Ω load)

Connectivity & I/O

ParameterValue
USB Interface StandardUSB 2.0 High Speed (USBTMC-USB488)

Environmental

ParameterValue
Pollution DegreePollution Degree 2
Operating EnvironmentIndoor use

Safety & Isolation

ParameterValue
Maximum Terminal-to-Ground Voltage60 VDC

Technology

Source Measure Unit (SMU)

Applications

Semiconductor IV Characterization, Automated Testing, Multi-Channel Parametric Measurement