The Keysight MSOX6004A is a high-performance 4-channel Mixed Signal Oscilloscope (MSO) from the InfiniiVision 6000 X-Series. It features a base bandwidth of 1 GHz (upgradable up to 6 GHz), 16 digital channels, a maximum sample rate of 20 GSa/s, and a 12.1-inch capacitive multi-touch display. It is designed with hardware zone touch triggering, multi-language voice control, and an industry-leading update rate to capture infrequent anomalies.

Specifications

General

ParameterValue
Display12.1-inch capacitive multi-touch LCD
Operating SystemEmbedded RTOS

Physical

ParameterValue
Power Supply100 to 240 V at 50/60 Hz; 100 to 120 V at 400 Hz
Operating Temperature0 to +50 °C

General Specifications

ParameterValue
Bandwidth1 GHz base (upgradable to 2.5 GHz, 4 GHz, 6 GHz)
Number of Analog Channels4
Number of Digital Channels16

Vertical System (Analog Channels)

ParameterValue
Input Impedance1 MΩ ± 1%, 50 Ω ± 1.5%
Input CouplingAC, DC
Vertical Resolution8 bits

Acquisition System

ParameterValue
Maximum Sample Rate (Half Channel)20 GSa/s
Maximum Sample Rate (All Channels)10 GSa/s
Maximum Memory Depth4 Mpts standard
Waveform Update Rate≥ 450,000 wfms/s
Segmented MemoryStandard
High Resolution ModeYes (up to 12 bits)

Trigger System

ParameterValue
Trigger ModesNormal, Auto, Single
Zone TriggeringHardware zone touch trigger standard

Waveform Measurements and Math

ParameterValue
Integrated Digital Voltmeter3-digit (Standard)

Integrated Arbitrary Waveform Generator (Optional)

ParameterValue
Integrated Arbitrary Waveform GeneratorOptional dual-channel 20 MHz

Display System

ParameterValue
Display Size12.1-inch
Display TypeCapacitive multi-touch LCD

Control and Software

ParameterValue
Voice ControlMulti-language voice control standard

Connectivity

ParameterValue
USB Host Ports3x USB 2.0 (2 front, 1 rear)
USB Device Port1x USB 2.0 (rear)

Digital Channels

ParameterValue
Maximum Toggle Rate400 MHz
Threshold SelectionsTTL, CMOS, ECL, PECL, User-defined

Environmental

ParameterValue
Operating HumidityUp to 80% RH at or below +40 °C (non-condensing)

Vertical System

ParameterValue
Vertical Sensitivity (1 MΩ)1 mV/div to 5 V/div
Vertical Sensitivity (50 Ω)1 mV/div to 1 V/div
DC Vertical Gain Accuracy±2.0% full scale
Channel-to-Channel Isolation≥ 100:1 (DC to 1 GHz)

Horizontal System

ParameterValue
Timebase Accuracy±1.6 ppm initial (+ 0.5 ppm/year aging)

Digital Channels (MSO)

ParameterValue
Digital Channel Minimum Voltage Swing400 mVpp
Digital Channel Input Capacitance8 pF (typical)

Waveform Math

ParameterValue
FFT PointsUp to 64 kpts

Technology

Mixed Signal Oscilloscope (MSO)

Applications

Embedded system design, analog/digital troubleshooting, signal integrity analysis, and high-speed serial bus testing.