The Keysight MSOX6004A is a high-performance 4-channel Mixed Signal Oscilloscope (MSO) from the InfiniiVision 6000 X-Series. It features a base bandwidth of 1 GHz (upgradable up to 6 GHz), 16 digital channels, a maximum sample rate of 20 GSa/s, and a 12.1-inch capacitive multi-touch display. It is designed with hardware zone touch triggering, multi-language voice control, and an industry-leading update rate to capture infrequent anomalies.
Specifications
General
| Parameter | Value |
|---|---|
| Display | 12.1-inch capacitive multi-touch LCD |
| Operating System | Embedded RTOS |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 100 to 240 V at 50/60 Hz; 100 to 120 V at 400 Hz |
| Operating Temperature | 0 to +50 °C |
General Specifications
| Parameter | Value |
|---|---|
| Bandwidth | 1 GHz base (upgradable to 2.5 GHz, 4 GHz, 6 GHz) |
| Number of Analog Channels | 4 |
| Number of Digital Channels | 16 |
Vertical System (Analog Channels)
| Parameter | Value |
|---|---|
| Input Impedance | 1 MΩ ± 1%, 50 Ω ± 1.5% |
| Input Coupling | AC, DC |
| Vertical Resolution | 8 bits |
Acquisition System
| Parameter | Value |
|---|---|
| Maximum Sample Rate (Half Channel) | 20 GSa/s |
| Maximum Sample Rate (All Channels) | 10 GSa/s |
| Maximum Memory Depth | 4 Mpts standard |
| Waveform Update Rate | ≥ 450,000 wfms/s |
| Segmented Memory | Standard |
| High Resolution Mode | Yes (up to 12 bits) |
Trigger System
| Parameter | Value |
|---|---|
| Trigger Modes | Normal, Auto, Single |
| Zone Triggering | Hardware zone touch trigger standard |
Waveform Measurements and Math
| Parameter | Value |
|---|---|
| Integrated Digital Voltmeter | 3-digit (Standard) |
Integrated Arbitrary Waveform Generator (Optional)
| Parameter | Value |
|---|---|
| Integrated Arbitrary Waveform Generator | Optional dual-channel 20 MHz |
Display System
| Parameter | Value |
|---|---|
| Display Size | 12.1-inch |
| Display Type | Capacitive multi-touch LCD |
Control and Software
| Parameter | Value |
|---|---|
| Voice Control | Multi-language voice control standard |
Connectivity
| Parameter | Value |
|---|---|
| USB Host Ports | 3x USB 2.0 (2 front, 1 rear) |
| USB Device Port | 1x USB 2.0 (rear) |
Digital Channels
| Parameter | Value |
|---|---|
| Maximum Toggle Rate | 400 MHz |
| Threshold Selections | TTL, CMOS, ECL, PECL, User-defined |
Environmental
| Parameter | Value |
|---|---|
| Operating Humidity | Up to 80% RH at or below +40 °C (non-condensing) |
Vertical System
| Parameter | Value |
|---|---|
| Vertical Sensitivity (1 MΩ) | 1 mV/div to 5 V/div |
| Vertical Sensitivity (50 Ω) | 1 mV/div to 1 V/div |
| DC Vertical Gain Accuracy | ±2.0% full scale |
| Channel-to-Channel Isolation | ≥ 100:1 (DC to 1 GHz) |
Horizontal System
| Parameter | Value |
|---|---|
| Timebase Accuracy | ±1.6 ppm initial (+ 0.5 ppm/year aging) |
Digital Channels (MSO)
| Parameter | Value |
|---|---|
| Digital Channel Minimum Voltage Swing | 400 mVpp |
| Digital Channel Input Capacitance | 8 pF (typical) |
Waveform Math
| Parameter | Value |
|---|---|
| FFT Points | Up to 64 kpts |
Technology
Mixed Signal Oscilloscope (MSO)
Applications
Embedded system design, analog/digital troubleshooting, signal integrity analysis, and high-speed serial bus testing.