The Keysight InfiniiVision MSOX3104T is a high-performance 1 GHz, 4-channel mixed signal oscilloscope featuring 16 integrated digital channels. Standard with an 8.5-inch capacitive touchscreen, the MSOX3104T integrates multiple instruments into one, featuring a class-leading waveform update rate of over 1,000,000 waveforms per second and standard zone touch triggering for simplified signal isolation.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | USB 2.0 host (two front, one rear), USB 2.0 device, LAN (10/100Base-T), WVGA video out |
| Display | 8.5-inch WVGA capacitive touch screen TFT-LCD (800 x 480) |
| Internal Storage | 4 GB internal non-volatile memory |
| Kensington Lock Slot | Yes (rear panel) |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 100 to 120 V (50/60/400 Hz), 100 to 240 V (50/60 Hz), 100 W max |
| Operating Temperature | 0 °C to +55 °C |
| Dimensions (W×H×D) | 381 mm × 204 mm × 142 mm |
| Weight | 3.85 kg |
Analog Vertical System
| Parameter | Value |
|---|---|
| Analog Input Channels | 4 |
| Analog Bandwidth (-3 dB) | 1 GHz |
| Calculated Rise Time (10% to 90%) | 350 ps |
| Input Coupling | AC, DC |
| Input Impedance | 1 MΩ ±1% (14 pF), 50 Ω ±1.5% |
| Input Sensitivity Range | 1 mV/div to 5 V/div (1 MΩ), 1 mV/div to 1 V/div (50 Ω) |
| Vertical Resolution | 8 bits |
| Max Input Voltage (1 MOhm) | 300 Vrms, 400 Vpk CAT I |
| Max Input Voltage (50 Ohm) | 5 Vrms CAT I |
| DC Gain Accuracy | ±2.0% full scale (≥ 10 mV/div), ±3.0% full scale (< 10 mV/div) |
| Offset Range | ±2 V (1 mV/div to 200 mV/div), ±50 V (> 200 mV/div to 5 V/div) for 1 MΩ |
| Channel-to-Channel Isolation | ≥ 40 dB (DC to 1 GHz) |
Digital Vertical System
| Parameter | Value |
|---|---|
| Digital Channels | 16 |
| Threshold Grouping | Pod 1 (D0 to D7), Pod 2 (D8 to D15) |
| Threshold Selections | TTL (+1.4 V), 5V CMOS (+2.5 V), 3.3V CMOS (+1.65 V), 2.5V CMOS (+1.25 V), ECL (-1.3 V), PECL (+3.7 V), User-defined |
| Threshold Voltage Range | ±8.0 V in 10 mV steps |
| Threshold Accuracy | ±(100 mV + 3% of threshold setting) |
| Input Impedance (Digital Probe) | 100 kΩ ±2% (~8 pF) at probe tip |
| Max Input Voltage (Digital Probe) | ±40 V peak |
| Minimum Voltage Swing | 500 mVpp |
| Minimum Detectable Pulse Width | 5 ns |
| Maximum Toggle Rate | 250 MHz |
Horizontal System
| Parameter | Value |
|---|---|
| Maximum Real-time Sample Rate (Analog) | 5 GSa/s (half-channel), 2.5 GSa/s (all channels) |
| Maximum Sample Rate (Digital) | 1.25 GSa/s (all channels) |
| Maximum Record Length (Analog Channels) | 4 Mpts (half-channel), 2 Mpts (all channels) |
| Maximum Record Length (Digital Channels) | 4 Mpts (one pod), 2 Mpts (two pods) |
| Time Base Range | 500 ps/div to 50 s/div |
| Time Base Delay Range | Pre-trigger: Greater of 1 screen width or 250 µs; Post-trigger: 1 s to 500 s |
| Channel-to-Channel Deskew Range | ±75 ns |
| Time Base Accuracy | ±1.6 ppm (including aging) |
Trigger System
| Parameter | Value |
|---|---|
| Trigger Modes | Normal, Auto, Single, Force |
| Trigger Coupling | AC, DC, LF Reject, HF Reject, Noise Reject |
| Trigger Holdoff Range | 40 ns to 10.0 s |
| Trigger Sensitivity | 0.6 div or 4.5 mV (< 10 MHz), 1.0 div or 7.5 mV (10 MHz to 1 GHz) at 50 Ω |
| Edge Triggering | Rising, falling, alternating, or either edge on any channel |
| Pulse Width Triggering | 2 ns to 10 s |
| Runt Triggering | Trigger on a pulse that crosses one threshold but fails to cross the second threshold before crossing the first again |
| Timeout Triggering | Trigger when a channel stays high, low, or either for a specified time (40 ns to 10 s) |
| Logic Triggering | Trigger on any logical pattern of channels, qualified by a transition or duration |
| Setup and Hold Triggering | Trigger on setup time and/or hold time violations between clock and data |
| Rise/Fall Time Triggering | 2 ns to 10 s |
| Zone Touch Trigger | Draw a box on the screen to isolate signals with 'must intersect' or 'must not intersect' conditions |
Acquisition Modes
| Parameter | Value |
|---|---|
| Sample Mode | Standard acquisition mode |
| Peak Detect Mode | Capture glitches as narrow as 250 ps at all sweep speeds |
| Averaging Mode | Selectable from 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024, 65536 |
| High Resolution Mode | Real-time boxcar averaging reduces random noise and increases vertical resolution (up to 12 bits) |
| Segmented Memory Mode | Segmented memory optimizes acquisition memory for capturing low-duty-cycle events (up to 1000 segments) |
| Roll Mode | At slower time base settings (50 ms/div and slower) |
Waveform Analysis & Measurements
| Parameter | Value |
|---|---|
| Automatic Voltage Measurements | Peak-to-peak, Maximum, Minimum, Amplitude, Top, Base, Overshoot, Preshoot, Average, RMS |
| Automatic Time/Frequency Measurements | Period, Frequency, Rise time, Fall time, Positive width, Negative width, Duty cycle, Phase, Delay |
| Math Functions | Add, subtract, multiply, divide, FFT, integrate, differentiate, square root, Ax+B, Low pass filter, High pass filter |
| FFT Window Types | Hanning, Flat Top, Rectangular, Blackman-Harris |
Display & User Interface
| Parameter | Value |
|---|---|
| Waveform Update Rate | ≥ 1,000,000 waveforms per second |
Optional Integrated Instruments
| Parameter | Value |
|---|---|
| Arbitrary/Function Generator Channels | 1 channel (optional, WaveGen) |
| AFG Maximum Frequency | 20 MHz |
| AFG Waveforms | Sine, Square, Ramp, Pulse, DC, Noise, Sine Cardinal (Sinc), Exponential Rise, Exponential Fall, Cardiac, Gaussian, Arbitrary |
| AFG Vertical Resolution | 14 bits |
| Digital Voltmeter Channels | 3-digit DVM (standard, operates with same probes) |
| Frequency Counter Resolution | 8-digit hardware frequency counter (standard) |
Environmental & Compliance
| Parameter | Value |
|---|---|
| Non-Operating Temperature Range | -40 °C to +70 °C |
| Operating Humidity Range | Up to 95% RH at +40 °C (non-condensing) |
| Operating Altitude | Up to 3,000 m (9,842 ft) |
Accessories
| Parameter | Value |
|---|---|
| Standard Analog Probes | N2894A 700 MHz passive probe (1 per analog channel) |
| Standard Digital Probe | N2756A 16-channel MSO cable kit |
Maintenance
| Parameter | Value |
|---|---|
| Calibration Interval | 2 years |
Inputs & Outputs
| Parameter | Value |
|---|---|
| Probe Interface | AutoProbe interface |
Search & Navigate
| Parameter | Value |
|---|---|
| Hardware Search | Search and navigate on edge, pulse width, rise/fall time, runt, setup/hold, and serial packets |
Connectivity Options
| Parameter | Value |
|---|---|
| Optional LAN/VGA Interface | Standard (built-in LAN and VGA) |
| Optional GPIB Interface | DSOXGPIB module |
Acquisition
| Parameter | Value |
|---|---|
| Segmented Memory Max Segments | 1000 |
Environmental
| Parameter | Value |
|---|---|
| Operating Vibration | Meets MIL-PRF-28800F Class 3 random |
| Operating Shock | Meets MIL-PRF-28800F Class 3, 30 g, half-sine, 11 ms |
Analysis
| Parameter | Value |
|---|---|
| Frequency Response Analysis (Bode Plot) | 10 Hz to 20 MHz (requires WaveGen option) |
Connectivity
| Parameter | Value |
|---|---|
| USB Host Ports | 3 ports (2 front, 1 rear), USB 2.0 |
| USB Device Port | 1 port (rear), USB 2.0 High-Speed |
| LXI Compliance | LXI Class C |
| Trigger Out BNC | Yes (rear panel) |
Analog Inputs
| Parameter | Value |
|---|---|
| Hardware Bandwidth Limit | 20 MHz (selectable) |
| Probe Attenuation Factors | 0.1X to 10000X |
Trigger
| Parameter | Value |
|---|---|
| Trigger Jitter | < 1.6 ps RMS |
| Trigger Types (Optional Serial) | I2C, SPI, UART/RS232/RS422/RS485, CAN, CAN FD, LIN, FlexRay, SENT, CXPI, I2S, MIL-STD 1553, ARINC 429, USB 2.0 |
Digital Channels
| Parameter | Value |
|---|---|
| Digital Channel Timing Resolution | 625 ps |
Technology
InfiniiVision 3000T X-Series
Applications
Mixed-signal design and debug, embedded systems, automotive electronics, power analysis