Frequency Parameter Value Minimum Frequency 9 kHz Maximum Frequency 6 GHz (option dependent) Frequency Resolution 0.01 Hz
Output Parameter Value Maximum Output Power +18 dBm (standard, up to +26 dBm with option 1EA) Output Power Range -110 to +18 dBm (standard, frequency dependent) Phase Noise -119 dBc/Hz (typical at 20 kHz offset, 1 GHz carrier)
Modulation Parameter Value Modulation AM, FM, Phase (ΦM), Pulse, Vector I/Q (internal and external) Sweep Modes Step, List (frequency, amplitude, and dwell)
General Parameter Value Reference Oscillator 10 MHz (internal) Interfaces LAN (1000Base-T), USB 2.0, GPIB (optional) Display 6.5-inch color TFT LCD Calibration Cycle 3 years
Physical Parameter Value Dimensions (W×H×D) 426 mm W × 88 mm H × 489 mm D Weight 15.9 kg
Frequency Specifications Parameter Value Frequency Options 3 GHz (Option 503), 6 GHz (Option 506) Frequency Switching Speed < 5 ms (typical, SCPI mode) Internal Reference Aging Rate < ±1 ppm/year External Reference Input Frequency 10 MHz (±1 ppm)
Amplitude Specifications Parameter Value Amplitude Resolution 0.02 dB Output Impedance 50 ohms
Spectral Purity Parameter Value Harmonics <-30 dBc (at 1 GHz, output power < +4 dBm)
Vector Modulation and Baseband Parameter Value Internal Baseband Generator Bandwidth 60 MHz (standard), 120 MHz (Option 1RE) Arbitrary Waveform Memory Depth 16 Msa (standard), up to 512 Msa (Option 512) Digital-to-Analog Converter (DAC) Resolution 16-bit
System Connectivity and Interfaces Parameter Value RF Output Connector Type Type-N female LXI Class Compliance LXI Core 2011 compliant
Physical and Environmental Specifications Parameter Value Operating Temperature Range 0 to 55 °C Storage Temperature Range -40 to 70 °C Rack Unit (RU) Height 2U
Protection Parameter Value RF Reverse Power Protection 50 W (nominal) below 2 GHz, 25 W (nominal) 2 GHz to 6 GHz, 50 VDC maximum
Phase Parameter Value Phase Offset Resolution 0.01°
Baseband Generator Parameter Value Internal Baseband Generator Max Sample Rate 150 MSa/s
Environmental Parameter Value Maximum Operating Altitude 4,600 m Maximum Storage Altitude 15,200 m Environmental Shock & Vibration Meets MIL-PRF-28800F Class 3 limits Relative Humidity Range Up to 95% RH at 40 °C, non-condensing
Sweep Parameter Value Sweep Points Range 2 to 65535
Performance Parameter Value W-CDMA ACLR (64 DPCH) -73 dBc (typical, at 2 GHz) LTE-A FDD EVM < 0.4% (typical, 1.8 GHz to 2.2 GHz)
Options Parameter Value Baseband Generator Bandwidth Options 60 MHz (Option 1EL) / 80 MHz (Option 1EM) / 120 MHz (Option 1EP) Baseband Generator Memory Options 32 MSa (Option 022) / 512 MSa (Option 023)