The Kikusui PLZ334W is a high-performance, multifunctional programmable DC electronic load designed for testing power supplies, batteries, and electronic components. Operating within a range of 1.5 V to 150 V, it supports up to 66 A and 330 W. It features versatile operating modes, high-speed transient testing capabilities, sequence programming, and standard communication interfaces including USB, GPIB, and RS-232C.

Specifications

General

ParameterValue
InterfacesUSB 2.0, GPIB, RS-232C
DisplayMonochrome custom backlit LCD
Warm-up Time30 minutes

Physical

ParameterValue
Power Supply100 VAC to 240 VAC, 47 Hz to 63 Hz, 80 VA max
Operating Temperature0 to 40
Dimensions (W×H×D)214.5 x 124 x 400
Weight11.5

Input Ratings and Operating Ranges

ParameterValue
Maximum Input Power330 W
Maximum Input Voltage150 V
Maximum Input Current66 A
Minimum Operating Voltage1.5 V
Low Voltage Derating Threshold0.3 V (operates with derated current down to 0.3 V)
Parallel Operation CapacityUp to 5 units of the same model (1 master, 4 slaves)
Series OperationNot supported

Operating Modes & Accuracy

ParameterValue
Operating ModesConstant Current (CC), Constant Voltage (CV), Constant Resistance (CR), Constant Power (CP), CC+CV, CR+CV
Constant Current (CC) Range0 A to 66 A
Constant Voltage (CV) Range1.5 V to 150 V
Constant Resistance (CR) Range0.045 Ω to 45 kΩ (22 S to 22 µS)
Constant Power (CP) Range0.033 W to 330 W
CC Programming Accuracy±(0.2% of set + 0.1% of f.s.)
CV Programming Accuracy±(0.1% of set + 0.1% of f.s.)

Transient and Dynamic Characteristics

ParameterValue
Transient Mode Frequency Range1 Hz to 20 kHz
Transient Mode Duty Cycle Range1% to 99% (in 0.1% steps)
Current Slew Rate Range20 mA/µs to 10 A/µs
Slew Rate Resolution20 mA/µs
Normal Sequence Step Duration1 ms to 999 h 59 min
Fast Sequence Step Duration25 µs to 100 ms
Maximum Sequence Steps1024 steps per program

Measurement and Readback Accuracy

ParameterValue
Voltage Readback Range0 V to 150 V
Voltage Readback Accuracy±(0.1% of rdg + 0.1% of f.s.)
Current Readback Range0 A to 66 A
Current Readback Accuracy±(0.2% of rdg + 0.1% of f.s.)
Capacity Measurement (Ah) Range0.001 Ah to 9999 Ah
Capacity Measurement (Wh) Range0.01 Wh to 9999 Wh

Protection Features

ParameterValue
Over-Voltage Protection (OVP) Range1.5 V to 165 V / Off
Over-Current Protection (OCP) Range0.06 A to 72.6 A / Off
Over-Power Protection (OPP) Range0.33 W to 363 W / Off
Under-Voltage Protection (UVP) Range0 V to 150 V / Off
Over-Temperature Protection (OTP)Cuts off load when internal heatsink temperature exceeds limit
Reverse Voltage ProtectionBy-pass diode, maximum reverse current 66 A
External Load Off InputExternal contact closure to safely turn off the load input

Connectivity & Control Interfaces

ParameterValue
Analog Control Input0 V to 10 V external voltage or 0 to 10 kΩ resistance
Current Monitor Output0 V to 10 V (corresponds to 0% to 100% rated current)
Trigger ConnectorsBNC type for trigger output only

Physical and Mechanical Specifications

ParameterValue
Form FactorBenchtop, 3U rack-mount compatible (half-width)
Cooling ConfigurationForced air cooling by temperature-controlled fan

Environmental and Safety Compliance

ParameterValue
Storage Temperature Range-20 °C to 70 °C
Operating Humidity Range20% to 85% RH (no condensation)
Safety ComplianceCE marked (Low Voltage Directive)

Inputs & Outputs

ParameterValue
Front Panel Input Terminal Maximum Current30 A
Current Monitor Output Level10 V at full scale (H/M range), 1 V at full scale (L range)

Performance

ParameterValue
Remote Sensing Compensation Voltage2 V (one way)
Elapsed Time Measurement Range1 s to 999 h 59 min 59 s
Short-Circuit Equivalent ResistanceApprox. 20 mΩ
Soft Start Setting Options0.1 ms, 1 ms, 3 ms, 10 ms, 30 ms, 100 ms, 300 ms
Transient Mode Duty Cycle Resolution1%

Power

ParameterValue
Maximum Power Consumption95 VA

Safety & Isolation

ParameterValue
Insulation Resistance30 MΩ or more (at 500 Vdc)
Withstand Voltage1500 Vac for 1 minute (AC input to chassis), 500 Vdc for 1 minute (input terminal to chassis)

Control

ParameterValue
Fast Sequence Maximum Steps1024
Setup Memories100 channels (0 to 99)
Auto Load Off Timer Range1 s to 999 h 59 min 59 s (or off)
External Voltage Control Range0 V to 10 V (corresponds to 0% to 100% of rated value)
External Resistance Control Range0 kΩ to 10 kΩ (corresponds to 0% to 100% or 100% to 0% of rated value)

Technology

Active semiconductor-based DC electronic load

Applications

Power supply evaluation, battery discharge testing, solar panel testing, and alternator characterization