The Teledyne LeCroy CP150 is a high-performance 150 A, 10 MHz AC/DC current probe designed for seamless integration with Teledyne LeCroy oscilloscopes. Powered directly through the ProBus interface, it features automatic scaling, auto-zeroing, and de-gaussing control from the oscilloscope user interface.

Specifications

General

ParameterValue
InterfacesTeledyne LeCroy ProBus

Physical

ParameterValue
Power SupplyPowered directly from the oscilloscope via ProBus interface
Operating Temperature0 to 40 °C
Dimensions (W×H×D)176 mm × 69 mm × 27 mm (probe head)
Weight0.5 kg

Electrical & Performance Specifications

ParameterValue
Maximum Continuous Input Current150 A rms
Maximum Peak Current300 A peak (non-continuous)
Bandwidth (-3 dB)DC to 10 MHz
Rise Time≤ 35 ns
Output Voltage (Sensitivity)0.01 V/A (10 mV/A)
Amplitude Accuracy±1.0% of reading ±10 mA (up to 150 A)
Equivalent Input Noise≤ 25 mA rms
Insertion Impedance (at 50 Hz/60 Hz)0.01 Ω
Insertion Impedance (at 1 MHz)0.1 Ω

Connectivity & System Integration

ParameterValue
Interface TypeTeledyne LeCroy ProBus
Auto-Zero / De-gaussing ControlIntegrated via ProBus, operated from the oscilloscope UI

Physical & Mechanical Specifications

ParameterValue
Maximum Conductor Diameter20 mm
Output Cable Length2 m
Jaw Mechanism TypeClamp-on

Environmental Specifications

ParameterValue
Storage Temperature-10 °C to 50 °C
Operating Relative Humidity80% max (non-condensing)
Maximum Operating Altitude2000 m

Safety & Compliance

ParameterValue
Measurement Category (CAT Rating)CAT III 300 V, CAT II 600 V
Safety Standards ComplianceEN 61010-1, EN 61010-2-032
EMC Standards ComplianceEN 61326
Pollution Degree2
Maximum Rated Voltage to Earth300 V CAT III, 600 V CAT II (insulated conductor)

System Requirements

ParameterValue
Required Oscilloscope Input Impedance1 MΩ

Electrical Characteristics

ParameterValue
CouplingAC/DC
Sensor TypeHall effect and current transformer
Max External Magnetic Field Influence≤ 150 mA (in a DC or 60 Hz magnetic field of 400 A/m)

Accuracy

ParameterValue
Temperature Coefficient±2% f.s. or less (0 °C to 40 °C)

Power Requirements

ParameterValue
Maximum Rated Power5.5 VA (within maximum rated current)

Technology

Fluxgate-Hall Effect Hybrid

Applications

AC/DC Current Measurement