The Teledyne LeCroy HDO4054 is a 500 MHz, 4-channel digital oscilloscope featuring HD4096 high-definition technology. With its native 12-bit ADC resolution (extendable to 15-bit via ERES), a real-time sample rate of 2.5 GS/s, and a 12.1" multi-touch screen display, it delivers exceptional signal fidelity and comprehensive analytical tools for debug and validation.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | USB (host), USB (device), Ethernet port, External monitor port, GPIB port (optional), remote control via Windows automation or Teledyne LeCroy Remote Command Set |
| Display | 12.1" Color TFT LCD Touch Screen, 1280 x 800 (WXGA) resolution, YT and XY grid styles |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 100 - 240 VAC (±10%) at 50/60 Hz, 100 - 120 VAC (±10%) at 400 Hz; Max 200 W (250 W with options) |
| Operating Temperature | 5 to 40 |
| Dimensions (W×H×D) | 382 mm × 290 mm × 152 mm |
| Weight | 5.86 |
Vertical System
| Parameter | Value |
|---|---|
| Analog Bandwidth | 500 MHz |
| Calculated Rise Time (typical) | 700 ps |
| Number of Input Channels | 4 |
| Hardware Bandwidth Limits | 20 MHz, 200 MHz |
| Input Impedance | 1 MΩ ±2.0% || 16 pF, 50 Ω ±2.0% |
| Input Coupling | 1 MΩ: AC, DC, GND; 50 Ω: DC |
| Maximum Input Voltage | 1 MΩ: 400 V max (DC + Peak AC ≤ 10 kHz), 50 Ω: 5 VRMS |
| Channel-to-Channel Isolation | ≥ 30 dB |
| Vertical Resolution | 12-bit ADC (up to 15-bit with ERES) |
| Effective Number of Bits (ENOB) | 8.8 bits (typical) |
| Vertical Sensitivity Range (50 Ω) | 1 mV/div - 1 V/div |
| Vertical Sensitivity Range (1 MΩ) | 1 mV/div - 10 V/div |
Horizontal & Acquisition System
| Parameter | Value |
|---|---|
| Single-Shot Sample Rate (per channel) | 2.5 GS/s |
| Standard Memory Depth (Interleaved) | 25 Mpts/Ch |
| Standard Memory Depth (2 Channels active) | 12.5 Mpts/Ch |
| Optional Memory Depth (Interleaved) | 50 Mpts/Ch |
| Optional Memory Depth (2 Channels active) | 25 Mpts/Ch |
Trigger System
| Parameter | Value |
|---|---|
| Trigger Modes | Normal, Auto, Single, Stop |
| Trigger Sources | Ch 1 - Ch 4, EXT, EXT/10, AC Line |
| Trigger Coupling | AC, DC, LF Rej, HF Rej |
| Trigger Holdoff Range | 2 ns to 20 s, or 1 to 1,000,000,000 events |
| Standard Trigger Types | Edge, Glitch, Width, Logic (Pattern), TV (NTSC, PAL, SECAM, HDTV-720p, 1080i, 1080pi), Runt, Slew Rate, Interval (signal or pattern), Dropout, Qualified (State or Edge) |
| Optional Serial Data Triggers | I2C, SPI, UART/RS-232, CAN, LIN, FlexRay, SENT, MIL-STD-1553, ARINC 429, Audio (I2S, LJ, RJ, TDM), USB, USB-HSIC, MIPI D-PHY, DigRF3G |
| Trigger Jitter | < 2.8 ps rms (typical) |
Processor & Storage
| Parameter | Value |
|---|---|
| Waveform Storage | 4 memory waveforms plus internal HDD |
| Setup Storage | 6 setups |
Waveform Measurements & Analysis
| Parameter | Value |
|---|---|
| Math Traces | 1 Math trace |
| Math Functions | Add, Subtract, Multiply, Divide, FFT, Absolute Value, Averaging (summed and continuous), Derivative, Envelope, Enhanced Resolution, Floor, Integral, Invert, Reciprocal, Rescale, Roof, Square, Square Root, Trend, Zoom |
| Automatic Measurements | Up to 8 displayed simultaneously |
| Displayed Measurement Parameters | Amplitude, Area, Base, Delay, Delta Period @ Level, Delta Time @ Level, Duty Cycle, Duty @ Level, Edge @ Level, Fall Time (90% - 10%), Fall Time (80% - 20%), Frequency, Frequency @ Level, Maximum, Mean, Minimum, Overshoot+, Overshoot-, Period, Peak-Peak, Period @ Level, Phase, Rise Time (10% - 90%), Rise Time (20% - 80%), RMS, Skew, Standard Deviation, Time @ Level, Top, Width+, Width- |
| WaveScan Advanced Search and Find | Supported |
| LabNotebook Documentation | Supported |
| History Mode (Playback) | Supported |
| Power Analysis Software | Optional |
System
| Parameter | Value |
|---|---|
| Operating System | Windows Embedded Standard 7 (64-bit) |
| Standard System Memory | 4 GB |
Triggering
| Parameter | Value |
|---|---|
| External Trigger Input | 1 MΩ || 16 pF; Max input 400 Vpk |
Environmental
| Parameter | Value |
|---|---|
| Operating Humidity | 5% to 90% RH (non-condensing) up to +31 °C, derating linearly to 50% RH at +40 °C |
| Operating Altitude | Up to 3,000 m (10,000 ft) at or below +30 °C |
| Storage Temperature | -20 °C to +60 °C |
Outputs
| Parameter | Value |
|---|---|
| Calibration Output | 1 kHz, 1 V square wave |
Horizontal System
| Parameter | Value |
|---|---|
| Timebase Accuracy | ±1.5 ppm + (aging of 0.5 ppm/yr from last calibration) |
| Timebase Range | 100 ps/div - 1000 s/div |
Connectivity
| Parameter | Value |
|---|---|
| LXI Compliance | LXI Class C Compliant |
Acquisition System
| Parameter | Value |
|---|---|
| Random Interleaved Sampling (RIS) Rate | 125 GS/s |
| Waveform Interpolation | Linear, Sin(x)/x |
Display
| Parameter | Value |
|---|---|
| Grid Styles | Auto, Single, Dual, Quad, Octal, XY, Single+XY, Dual+XY |
Inputs & Outputs
| Parameter | Value |
|---|---|
| Auxiliary Output | Rear-panel BNC, provides AUX Trigger Out, Pass/Fail, or Calibration Out |
Standard Accessories
| Parameter | Value |
|---|---|
| Included Probes | 4 x PP018 (500 MHz, 10:1, 10 MΩ) |
Technology
HD4096 High Definition Technology
Applications
Electronic Test & Measurement, Serial Data Debugging, Power Analysis
Looking for the LeCroy (Teledyne LeCroy) HDO4054?
Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.