The Teledyne LeCroy HDO4054 is a 500 MHz, 4-channel digital oscilloscope featuring HD4096 high-definition technology. With its native 12-bit ADC resolution (extendable to 15-bit via ERES), a real-time sample rate of 2.5 GS/s, and a 12.1" multi-touch screen display, it delivers exceptional signal fidelity and comprehensive analytical tools for debug and validation.

Specifications

General

ParameterValue
InterfacesUSB (host), USB (device), Ethernet port, External monitor port, GPIB port (optional), remote control via Windows automation or Teledyne LeCroy Remote Command Set
Display12.1" Color TFT LCD Touch Screen, 1280 x 800 (WXGA) resolution, YT and XY grid styles

Physical

ParameterValue
Power Supply100 - 240 VAC (±10%) at 50/60 Hz, 100 - 120 VAC (±10%) at 400 Hz; Max 200 W (250 W with options)
Operating Temperature5 to 40
Dimensions (W×H×D)382 mm × 290 mm × 152 mm
Weight5.86

Vertical System

ParameterValue
Analog Bandwidth500 MHz
Calculated Rise Time (typical)700 ps
Number of Input Channels4
Hardware Bandwidth Limits20 MHz, 200 MHz
Input Impedance1 MΩ ±2.0% || 16 pF, 50 Ω ±2.0%
Input Coupling1 MΩ: AC, DC, GND; 50 Ω: DC
Maximum Input Voltage1 MΩ: 400 V max (DC + Peak AC ≤ 10 kHz), 50 Ω: 5 VRMS
Channel-to-Channel Isolation≥ 30 dB
Vertical Resolution12-bit ADC (up to 15-bit with ERES)
Effective Number of Bits (ENOB)8.8 bits (typical)
Vertical Sensitivity Range (50 Ω)1 mV/div - 1 V/div
Vertical Sensitivity Range (1 MΩ)1 mV/div - 10 V/div

Horizontal & Acquisition System

ParameterValue
Single-Shot Sample Rate (per channel)2.5 GS/s
Standard Memory Depth (Interleaved)25 Mpts/Ch
Standard Memory Depth (2 Channels active)12.5 Mpts/Ch
Optional Memory Depth (Interleaved)50 Mpts/Ch
Optional Memory Depth (2 Channels active)25 Mpts/Ch

Trigger System

ParameterValue
Trigger ModesNormal, Auto, Single, Stop
Trigger SourcesCh 1 - Ch 4, EXT, EXT/10, AC Line
Trigger CouplingAC, DC, LF Rej, HF Rej
Trigger Holdoff Range2 ns to 20 s, or 1 to 1,000,000,000 events
Standard Trigger TypesEdge, Glitch, Width, Logic (Pattern), TV (NTSC, PAL, SECAM, HDTV-720p, 1080i, 1080pi), Runt, Slew Rate, Interval (signal or pattern), Dropout, Qualified (State or Edge)
Optional Serial Data TriggersI2C, SPI, UART/RS-232, CAN, LIN, FlexRay, SENT, MIL-STD-1553, ARINC 429, Audio (I2S, LJ, RJ, TDM), USB, USB-HSIC, MIPI D-PHY, DigRF3G
Trigger Jitter< 2.8 ps rms (typical)

Processor & Storage

ParameterValue
Waveform Storage4 memory waveforms plus internal HDD
Setup Storage6 setups

Waveform Measurements & Analysis

ParameterValue
Math Traces1 Math trace
Math FunctionsAdd, Subtract, Multiply, Divide, FFT, Absolute Value, Averaging (summed and continuous), Derivative, Envelope, Enhanced Resolution, Floor, Integral, Invert, Reciprocal, Rescale, Roof, Square, Square Root, Trend, Zoom
Automatic MeasurementsUp to 8 displayed simultaneously
Displayed Measurement ParametersAmplitude, Area, Base, Delay, Delta Period @ Level, Delta Time @ Level, Duty Cycle, Duty @ Level, Edge @ Level, Fall Time (90% - 10%), Fall Time (80% - 20%), Frequency, Frequency @ Level, Maximum, Mean, Minimum, Overshoot+, Overshoot-, Period, Peak-Peak, Period @ Level, Phase, Rise Time (10% - 90%), Rise Time (20% - 80%), RMS, Skew, Standard Deviation, Time @ Level, Top, Width+, Width-
WaveScan Advanced Search and FindSupported
LabNotebook DocumentationSupported
History Mode (Playback)Supported
Power Analysis SoftwareOptional

System

ParameterValue
Operating SystemWindows Embedded Standard 7 (64-bit)
Standard System Memory4 GB

Triggering

ParameterValue
External Trigger Input1 MΩ || 16 pF; Max input 400 Vpk

Environmental

ParameterValue
Operating Humidity5% to 90% RH (non-condensing) up to +31 °C, derating linearly to 50% RH at +40 °C
Operating AltitudeUp to 3,000 m (10,000 ft) at or below +30 °C
Storage Temperature-20 °C to +60 °C

Outputs

ParameterValue
Calibration Output1 kHz, 1 V square wave

Horizontal System

ParameterValue
Timebase Accuracy±1.5 ppm + (aging of 0.5 ppm/yr from last calibration)
Timebase Range100 ps/div - 1000 s/div

Connectivity

ParameterValue
LXI ComplianceLXI Class C Compliant

Acquisition System

ParameterValue
Random Interleaved Sampling (RIS) Rate125 GS/s
Waveform InterpolationLinear, Sin(x)/x

Display

ParameterValue
Grid StylesAuto, Single, Dual, Quad, Octal, XY, Single+XY, Dual+XY

Inputs & Outputs

ParameterValue
Auxiliary OutputRear-panel BNC, provides AUX Trigger Out, Pass/Fail, or Calibration Out

Standard Accessories

ParameterValue
Included Probes4 x PP018 (500 MHz, 10:1, 10 MΩ)

Technology

HD4096 High Definition Technology

Applications

Electronic Test & Measurement, Serial Data Debugging, Power Analysis

Looking for the LeCroy (Teledyne LeCroy) HDO4054?

Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.